1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Applied anatomy" 19 results
        • ANATOMICAL STUDY OF RECONSTRUCTION OF VERTEBRAL ARTERY WITH NEIGHBORING NON-TRUNK ARTERIES

          OBJECTIVE: To study the anatomical basis for reconstruction of vertebral artery with neighboring non-trunk arteries. METHODS: Twenty preserved adult cadavers were used in this study to observe the morphology of superior thyroid artery, inferior thyroid artery, transverse cervical artery, thyrocervical trunk and extracerebral portion of vertebral artery, and reconstruction of vertebral artery with these arteries was simulated in two preserved cadavers. RESULTS: The calibers of superior or inferior thyroid artery, or transverse cervical artery were more than 2 mm in diameter, and the arteries had suitable free length for end-to-side anastomosis with vertebral artery. Thyrocervical artery had similar caliber to vertebral artery so that end-to-end anastomosis could be carried out between them, but only 38.5% of this artery had adequate artery trunk (more than 10 mm). It was proved from the simulated procedures that the reconstruction of vertebral artery with these neighboring non-trunk arteries was possible. CONCLUSION: Reconstruction of vertebral artery with neighboring non-trunk arteries has anatomical basis and can be used clinically for treatment of the lesion affecting the first or second portion of vertebral artery.

          Release date:2016-09-01 10:21 Export PDF Favorites Scan
        • EXPERIMENTAL STUDY ON KIDNEY ANATOMIC STRUCTURE OF BANNA MINIPIG INBRED-LINES FOR XENOTRANSPLANTATION

          OBJECTIVE: To explore the kidney anatomic structure of banna minipig inbred-lines, and to provide data for kidney xenotransplantation. METHODS: The fresh and infused kidneys of banna minipig (including the vessel and the ureter) were checked by anatomic microscope and vernier caliper in original location and away body. The tissue structure was observed by HE stain. RESULTS: The structure of kidney of banna minipig inbred-lines (including the vessel and the ureter) are similar to that of human being. The fascia propria of kidney is divided into three layers including capsula fibrosa, capsula adipose and fascia renalis. The thickness of cortex renalis is (20.0 +/- 2.4) mm. The average diameter of renal artery is 5.1 mm and is similar to that of human being. All the kidneys of banna minipig inbred-lines have a single branch renal artery. The diameters of left and right ureters are 5.1 mm and 4.7 mm, respectively. CONCLUSION: The kidney of banna minipig inbred-lines is an ideal replacement of human kidney for xenotransplantation.

          Release date:2016-09-01 10:15 Export PDF Favorites Scan
        • Applied Anatomical and Experimental Study of Retrohepatic Tunnel of Liver Hanging Maneuver

          Objective To study the clinical anatomical basis of the liver hanging maneuver through research of applied anatomy. Methods Retrohepatic portions of the inferior vena cava of 21 cadaver were observed intracavitarily, and the numbers of short hepatic vein (SHV) opening were counted based on different possible pathway of the liver hanging maneuver and different width of retrohepatic tunnel (10 mm, 6 mm). Results The number of SHV was 0 to 3 (median=1) using standard pathway of the liver hanging maneuver in 6 mm retrohepatic tunnel, and the number of SHV was 0 to 2 (median=0) using EM pathway that was on the right border of retrohepatic portion of the inferior vena cava and 1 cm away from the inferior border of liver. There was a significant difference between the EM pathway and standard pathway, P=0.003.Conclusion The results show that setting up a retrohepatic tunnel through the liver hanging maneuver is feasible and safe.

          Release date:2016-09-08 11:49 Export PDF Favorites Scan
        • ANATOMICAL STUDIES ON LOW END-TO-SIDE ANASTOMOSIS OF MEDIAN NERVE AND ULNAR NERVE IN REPAIR OF DEJERINE KLUMPKE TYPE PARALYSIS OR HIGH ULNAR NERVE INJURY

          Objective To investigate the anatomical evidence of low end-to-side anastomosis of median nerve and ulnar nerve in repair of Dejerine Klumpke type paralysis or high ulnar nerve injury. Methods Twelve formaldehyde anticorrosion specimens (24 sides) and 3 fresh specimens (6 sides) were observed. There were 9 males (18 sides) and 6 females(12 sides). The specimen dissected under the microscope. S-shape incision was made at palmar thenar approaching ulnar side, the profundus nervi ulnaris and superficial branch of ulnar nerve were separated through near end of incision, and the recurrent branch of median nerve and comman digital nerve of the ring finger were separated through far end of incision. The distances from pisiform bone to the start point of the recurrent branch of median nerve, and to the start point of comman digital nerve of the ring finger were measured. The width and thickness of the profundus nervi ulnaris and superficial branch of ulnar nerve, and the recurrent branch of median nerve and comman digital nerve of the ring finger were measured, and the cross-sectional area was calculated. The number of nerve fiber was determined with HE staining and argentaffin staining. Results The crosssectional area and the number of nerve fiber were (2.46 ± 1.03) mm2 and 1 305 ± 239 for the profundus nervi ulnaris, (2.62 ± 1.75) mm2 and 1 634 ± 343 for the recurrent branch of median nerve, (1.60 ± 1.39) mm2 and 1 201 ± 235 for the superficial branch of ulnar nerve, and (2.19 ± 0.89) mm2 and 1 362 ± 162 for the comman digital nerve of the ring finger. There were no significant differences (P gt; 0.05) in the cross-sectional area and the number of nerve fiber between the profundus nervi ulnaris and the recurrent branch of median nerve, between the superficial branch of ulnar nerve and the comman digital nerve of the ring finger; and two factors had a l inear correlation (P lt; 0.05) with correlation coefficients of 0.68, 0.66 and 0.56, 0.36. The distances were (36.98 ± 4.93) mm from pisiform bone to the start point of the recurrent branch of median nerve, and (28.35 ± 6.63) mm to the start point of comman digital nerve of the ring finger. Conclusion Low end-to-side anastomosis of median nerve and ulnar nerve has perfect match in the cross-sectional area and the number of nerve fiber.

          Release date:2016-08-31 05:47 Export PDF Favorites Scan
        • APPLIED ANATOMIC STUDY ON BLOOD SUPPLY FOR EXTRACRANIAL SEGMENT OF FACIAL NERVE

          Objective To explore the arterial origin and the distribution of the extracranial branches of the facial nerve. Methods Red latex or red chlorinated polyvinyl chloride was injected into the arteries of 15 fresh adult head specimens by both common carotid artery catheterization. The arterial origin and distribution of the extracranial branches of the facial nerve were observed. Results The nutrient arteries of the extracranial branches of the facial nerve originated from stylomastoid artery of the posterior auricular artery, the facial nervous branch of superficial temporal artery, transverse facial artery, superior and inferior facial nervous branches of external carotid artery and the posteriorand anterior facial nervous branches of external carotid artery. The outer diameters of them were (0.8±0.2) mm, (0.9±0.4) mm, (1.9±0.3) mm, (1.0±0.2) mm, (1.1±0.4) mm, (1.0±0.2) mm and (1.1±0.6) mm respectively. The sub-branches ofthe attendant artery of the facial nerve anastomosed each other in addition to supplying their own nerve, and a rich vascular network was formed between the facial nerve and adjacent tissue. Conclusion The study on blood supply of the extracranial segment of the facial nerve can provide anatomic basis for avoiding injury of the nutrient arteries of the facial nerve during operation of the parotidean and masseteric region clinically.

          Release date:2016-09-01 09:33 Export PDF Favorites Scan
        • ANATOMICAL STUDY ON RESTORATION OF THE SENSATION OF DISTAL BASED SURAL ISLAND FLAP

          Objective To investigate the anatomic foundation of using main branch of posterior femoral nerve to restore the sensation function of distal basedsural island flap. Methods Thirty cases of adult human cadaver legs fixed by 4%formaldehyde were used. Anatomical investigation of the posterior femoral nerves of lower legs was conducted under surgical microscope to observe their distribution, branches and their relationship with small saphenous vein. Nerve brancheswith diameter more than 0.1 mm were dissected and accounted during observation.The length and diameter of the nerves were measured. Results The main branch of posterior femoral nerve ran downwards from popliteal fossa within superficial fascia along with small saphenous vein. 70% of the main branch of the posterior femoral nerves lay medially to small saphenous vein, and 30% laterally. They wereclassified into 3 types according to their distribution in lower legs: typeⅠ (33.3%) innervated the upper 1/4 region of lower leg (region Ⅰ), type Ⅱ (43.3%) had branches in upper 1/2 region (region Ⅰ and Ⅱ), and type Ⅲ (23.3%) distributed over the upper 3/4 region (region Ⅰ, Ⅱ and Ⅲ). In type Ⅱ, the diameter of the main branches of posterior femoral nerves in the middle of popliteal tossa was 10±04 mm and innervated the posterior upper-middle region (which was the ordirary donor region of distal based sural island flaps) of lower legs with 2.0±0.8 branches, whose diameter was 0.3±0.2 mm and length was 3.5±2.7 mm. The distance between the end of these branches and small saphenous vein was 0.8±0.6 mm. In type Ⅲ, their diameter was 1.2±0.3 mm and innervated the posterior upper-middle region of lower legs with 3.7±1.7 branches, whose diameter was 0.4±0.1 mm and length was 3.7±2.6 mm. The distancebetween the end of these branches and small saphenous vein was 0.8±0.4 mm. Conclusion 66.6% of human main branch of posteriorfemoral nerves (type Ⅱ and type Ⅲ) can be used to restore the sensation of distal based sural island flap through anastomosis with sensor nerve stump of footduring operation.

          Release date:2016-09-01 09:24 Export PDF Favorites Scan
        • ANATOMICAL STUDY ON ANTERIOR TRANSPOSITION OF ULNAR NERVE ACCOMPANIED WITH ARTERIES FOR CUBITAL TUNNEL SYNDROME

          Objective To investigate the blood supply of the ulnar nerve in the elbow region and to design the procedure of anterior transposition of ulnar nerve accompanied with arteries for cubital tunnel syndrome.Methods The vascularity of the ulnar nerve was observed and measured in20adult cadaver upper limb specimens. And the clinical surgical procedure was imitated in 3 adult cadaver upper limb specimens. Results There were three major arteries to supply the ulnar nerve at the elbow region: the superior ulnar collateral artery, the inferior ulnar collateral artery and the posterior ulnar recurrent artery. The distances from arterial origin to the medial epicondyle were 14.2±0.9, 4.2±0.6 and 4.8±1.1 cm respectively. And the total length of the vessels travelling alone with the ulnar nerve were 15.0±1.3,5.1±0.3 and 5.6±0.9 cm. The external diameter of the arteries at the beginning spot were 1.5±0.5, 1.2±0.3 and 1.4±0.5 mm respectively. The perpendicular distance of the three arteries were 1.2±0.5,2.7±0.9 and 1.3±0.5 cm respectively.Conclusion It is feasible to perform anterior transposition of the ulnar nerve accompanied with arteries for cubital tunnel syndrome. And the procedure preserves the blood supply of the ulnar nerve following transposition. 

          Release date:2016-09-01 09:20 Export PDF Favorites Scan
        • APPLIED ANATOMICAL STUDY ON APPROACH NEXT TO ERECTOR SPINAE FOR SPINAL CANAL DECOMPRESSION THROUGH INTERVERTEBRAL FORAMEN

          Objective To observe and measure the approach next to the erector spinae in the thoracic and lumbar segments of the spine and adjacent anatomical structures by the topographic method, to clarify the positioning method and safe range so as to provide the anatomical basis of the approach for spinal canal decompression. Methods Twelve formaldehyde-treated adult cadaver specimens were selected, including 6 males and 6 females with an average age of 43 years (range, 27-52 years) and with an average height of 166 cm (range, 154-177 cm). The related data of the approach at T1-S1 levels were respectively measured: the distance between the lateral edge of the erector spinae and the spinous process, the length of the approach, the angle between the approach and the horizontal plane, the size of intervertebral foramen, and the vertical distance between the segmental artery and the upper edge of the vertebrae. Results The distance between the lateral edge of the erector spinae and the spinous process ranged from (41.75 ± 3.29) mm to (74.54 ± 7.08) mm. The length of the approach ranged from (66.75 ± 10.81) mm to (97.13 ± 13.35) mm. The angle between the approach and the horizontal plane ranged from (38.38 ± 6.16)° to (53.67 ± 4.40)°. The vertical distance between the segmental artery and the upper edge of the vertebrae ranged from (9.50 ± 0.60) mm to (18.30 ± 1.56) mm. The size of foraminal was also measured. The spinal canal could reach when iliocostalis lateral edge was used as the starting point in the lumbar segments, and longissimus lateral edge as the starting point in the thoracic segments. It was confirmed that there was enough safe space for the spinal decompression without the resection of the articular process. Conclusion The approach next to the erector spinae can reach spinal canal to achieve the purpose of decompression through the intervertebral foramen. The minimally invasive approach is feasible and safe. It has the value of the operative application.

          Release date:2016-08-31 04:07 Export PDF Favorites Scan
        • APPLIED ANATOMY OF THE SECOND DORSAL METACARPAL ARTERY ISLAND FLAP WITH DOUBLE PIVOT POINTS

          Objective To provide the anatomic bases for clinical application of the second dorsal metacarpal artery(SDMA) island flap with double pivot points. Methods The origin,branches and distribution of the recurrent cutaneous branch of the SDMA were observed in 30 adult fresh cadaver specimens, which were illustrated with special dye.Eighteen cases of skin defets of the thumb were repaired with the SDMA island flap. The defect locations were the dorsal part in 11 cases and palmar part in 7 cases, including 3 cases of defect in association with long pollical extensor defect and 2 cases of defect in association with dorsal skin defect of proximal finger. The flap area ranged from 2 cm×3 cmto 3 cm×5 cm. Results The appearance of therecurrent cutaneous branch of the SDMA was observed in all cases(100%), which originated 0.5±0.2 cm distant from the distal intersectiones between the SDMA and the index extensor and disappeared 1.2±0.5 cm distant from the proximal metacarpophalangeal joint. The branches of 1.7±0.7 were seen with a longitudinal fan-like distributionforward proximal part on the deep surface of the dorsal superficial vein. The exradius and the length of the recurrent cutaneous branch of the SDMA were 0.3±0.1 mm and 6.5±0.8 mm, respectively. The transplanted flaps survived in all cases and 16 cases were followed up for 8-14 months. The colour and appearance of the skin were satisfactory. The two-point discriminations were 0.9 mm in 3 cases by bridging digital nerve and 1.1 mm in 9 cases by anastomosing dorsal digital nerve; while the two-point discrimination was 13-15 mm in 4 cases without anastomosing nerve. Conclusion The origin,branches and distribution of the recurrent cutaneous branch of the SDMA is constant, which provide a potentially longer pedicle and increase the possibility to rotate the flap and also avoid the donor skin defect of rotation of the flap.

          Release date:2016-09-01 09:30 Export PDF Favorites Scan
        • AN ANATOMIC STUDY OF LAG SCREW PLACEMENT IN ANTERIOR COLUMN OF ACETABULUM AND DESIGN OF TARGETING DEVICE

          Objective To provide the anatomic basis for thelag screw placement in the anterior column of the acetabulum. Methods Twenty-two pelvis specimens with 44 acetabula of the native adult cadavers were studied. The anthropometric measurement was performed on 44 acetabula to determine the shape of the transverse section of the anterior column of the acetabulum, the optimal entry point for the lag screw on the outer table of the ilium, the direction of the screw, and the distance from the entry point to the obturator groove. Results The transverse section of the anterior column of the acetabulum was almost triangle-shaped. The path for the lag screw placement was 10.5±0.8 mm in diameter. The optimal entry point on the posterolateral ilium for the screw fixation was found toexist 9.2±2.4 mm superior to the line between the anterior superior iliac spine and the greater sciatic notch and 38.5±3.8 mm superior to the greater sciatic notch. The distance from the entry point to the obturator groove was 84.1±6.2 mm. The inclination of the lag screw was 54.2±5.5° at the caudal direction in the sagittal plane and 40.7±3.8° in the horizontal plane. The device for the safe screw placement in the anterior column was designed. Conclusion The above datacan facilitate an insertion of one 6.5 mm lag screw into the anterior acetabular column and minimize the risk of articular violation or cortical penetration, which has a narrow margin of safety. The safe length of the lag screw should be 70 mm.The optimal entry point on the posterolateral ilium for the screw fixationis determined to be 10 mm superior to the line between the anterior superior iliac spine and the greater sciatic notch and 40 mm superior to the greater sciatic notch. The inclination of the lag screw should be 55° at the caudal direction in the sagittal plane and 40° in the horizontal plane. It is safe to place thelag screw in the anterior column with the help of the targeting device.

          Release date:2016-09-01 09:26 Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品