1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Bicuspid aortic valve" 19 results
        • Surgical Treatment of Bicuspid Aortic Valve Combined with Toracic Aortic Dilation

          ObjectiveTo analyze the clinical characteristics and surgical treatment of bicuspid aortic valve combined with thoracic aortic dilation. MethodsWe retrospectively analyzed the clinical data of 68 patients of bicuspid aortic valve combined with thoracic aortic dilation underwent surgical treatment in our hospital between January 2010 and June 2014. There were 47 males and 21 females at age of 26-77(44.5±16.3) years. Different surgical treatments including Wheat procedure(n=22), aortic valve replacement+ascending aortoplasty(n=10), Bentall procedure(n=13), aortic valve replacement+ascending aortic replacement+right hemi aortic arch replacement(n=13), Bentall procedure+ascending aortic replacement+right hemi aortic arch replacement(n=8), Bentall procedure+ascending aortic replacement+total arch replacement+stented elephant trunk(n=2) were carried out according to the type. ResultsAll 68 patients underwent surgical treatment. The mortality in hospital is at 4.4%(3/68). The postoperative complications were neurological and mental complications(n=3), pneumonia(n=2), and exploratory thoracotomy(n=2). We followed up 63 patients for 6 months to 4 years. A total of 62 patients were well without reoperation except one death at the end of following-up 2 years. ConclusionBicuspid aortic valve combined with thoracic aortic dilation has diversiform clinical characteristics. The surgical treatment should be chosen according to the aortic valve and thoracic aortic lesion characteristics.

          Release date: Export PDF Favorites Scan
        • A case report of transcatheter aortic valve replacement for horizontal heart with aortic stenosis

          A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Multidetector CT characteristics of bicuspid aortic valve before transcatheter aortic valve replacement in single center

          ObjectiveTo explore the preoperative evaluation result of multidetector computed tomography (MDCT) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve replacement (TAVR) in order to summarize relevant experience.MethodsA total of 33 consecutive AS patients who underwent TAVR in Department of Cardiology, First Affiliated Hospital of Xinjiang Medical University from March 2016 to June 2020 were enrolled, and the preoperative evaluation characteristics of MDCT were compared between tricuspid aortic valve (TAV) and BAV.ResultsIn the 33 patients, whose mean age was (74±6) years, 22 were male and 11 were female, 17 were with BAV and 16 were with TAV. The medium (lower quartile, upper quartile) of calcification score was 360 (192, 1 034) mm3. There were 12 cases of artificial valve model to be speculated Downsize, including 9 calcific BAV cases (75%).ConclusionThe calcific BAV has a higher ratio of Downsize in the TAVR procedure.

          Release date:2020-10-26 03:00 Export PDF Favorites Scan
        • Predictive factors of new-onset conduction abnormalities after transcatheter aortic valve replacement in patients with bicuspid aortic valve: a meta-analysis

          ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=?1.48, 95%CI ?2.73 to ?0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=?2.06, 95%CI ?2.96 to ?1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.

          Release date:2023-06-20 01:48 Export PDF Favorites Scan
        • Remodeling+Ring (modified Yacoub) technique for the treatment of bicuspid aortic valve regurgitation with ascending aortic aneurysm: A case report

          Patients with bicuspid aortic valve are often complicated with aortic dilatation. If the aortic valve is of good quality, aortic root replacement with aortic valve preservation is feasible. A 35-year-old male patient with bicuspid aortic regurgitation complicated with ascending aortic aneurysm underwent Remodeling+Ring (modified Yacoub) operation. Echocardiography showed that there was no aortic regurgitation on the 3rd day after operation, and the patient was discharged satisfactorily on the 6th day after operation. Remodeling+Ring surgery ensures the physiological movement of the aortic valve, solves the enlarged annulus, avoids the problems caused by valve replacement, and significantly improves the quality of life of patients, which is worth popularizing.

          Release date:2022-01-21 01:31 Export PDF Favorites Scan
        • Bioinformatics analysis for bicuspid aortic valve with ascending aorta dilation

          Objective To explore the key genes, pathways and immune cell infiltration of bicuspid aortic valve (BAV) with ascending aortic dilation by bioinformatics analysis. Methods The data set GSE83675 was downloaded from the Gene Expression Omnibus database (up to May 12th, 2022). Differentially expressed genes (DEGs) were analyzed and gene set enrichment analysis (GSEA) was conducted using R language. STRING database and Cytoscape software were used to construct protein-protein interaction (PPI) network and identify hub genes. The proportion of immune cells infiltration was calculated by CIBERSORT deconvolution algorithm. Results There were 199 DEGs identified, including 19 up-regulated DEGs and 180 down-regulated DEGs. GSEA showed that the main enrichment pathways were cytokine-cytokine receptor interaction, pathways in cancer, regulation of actin cytoskeleton, chemokine signaling pathway and mitogen-activated protein kinase signaling pathway. Ten hub genes (EGFR, RIMS3, DLGAP2, RAPH1, CCNB3, CD3E, PIK3R5, TP73, PAK3, and AGAP2) were identified in PPI network. CIBERSORT analysis showed that activated natural killer cells were significantly higher in dilated aorta with BAV. Conclusions These identified key genes and pathways provide new insights into BAV aortopathy. Activated natural killer cells may participate in the dilation of ascending aorta with BAV.

          Release date:2022-09-30 08:46 Export PDF Favorites Scan
        • The clinical effect of a combined technical system for bicuspid aortic valves repair

          ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

          Release date:2023-07-10 04:06 Export PDF Favorites Scan
        • Transcatheter aortic valve replacement for a patient with bicuspid aortic valve stenosis characterized by leaflet thickening: a case report

          Due to the lack of calcification of the aortic valve, it is difficult to provide effective support for the fixation of artificial valve in aortic stenosis characterized by leaflet thickening. There is a risk of postoperative perivalvular leakage and secondary valve implantation, which is widely regarded as a relative contraindication for transcatheter aortic valve replacement (TAVR). But aortic valvuloplasty and self-expanding transcatheter aortic valve has showed its safety and efficacy. This paper reports a patient with bicuspid aortic valve characterized by leaflet thickening treated with TAVR. After the operation, the patient’s symptom of exertional dyspnea was significantly improved, New York Heart Association class increased to Ⅱ, no perivalvular leakage was found, and the mean transaortic pressure gradient and the maximum aortic valve velocity decreased significantly.

          Release date:2020-05-26 02:34 Export PDF Favorites Scan
        • Comparison of efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients with bicuspid versus tricuspid aortic valves

          Objective To compare the efficacy and safety of transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with bicuspid aortic valve (BAV) versus tricuspid aortic valve (TAV). Methods This retrospective study included 252 consecutive patients with severe and symptomatic aortic valve stenosis undergoing TAVR in West China Hospital form April 2012 to September 2017, in whom 4 patients were excluded because of valve failure after surgical aortic valve replacement. Results Of the 248 patients, 131 had BAV and 117 had TAV. Baseline characteristics were similar between the two groups, including age [(73.56±6.35) vs. (74.31±6.35) years, P=0.354], male proportion (51.9% vs. 63.2%, P=0.072). Society of Thoracic Surgeons score for BAV patients was lower than that for TAV patients [(7.56±4.01)% vs. (8.78±5.14)%, P=0.037]. Procedural success rate was high in both BAV and TAV groups (95.4% vs. 98.3%, P=0.359). There was no difference in 30-day all-cause mortality (6.1% vs. 2.6%, P=0.176) between the two groups; the aortic valve maximum velocity of valve hemodynamics after TAVR was similiar [(2.39±0.53) vs. (2.31±0.45) m/s, P=0.262] between the two groups. Conclusions Patients with BAV show similar procedural and clinical outcomes to patients with TAV. Therefore, TAVR appears to be a safe and effective procedure for patients with BAV as well as those with TAV.

          Release date:2018-02-26 05:32 Export PDF Favorites Scan
        • Interpretation of 2015 Experts Consensus for Transcatheter Aortic Valve Replacement

          Transcatheter aortic valve replacement (TAVR) developed rapidly since firstly introduced to clinical practice in 2002. In 2015, Experts Consensus for Transeatheter Aortic Valve Replacement (abbreviated as the Consensus) helped TAVR develop normatively and safely in China. This article interpreted the Consensus in combination of new evolutions of TAVR field: first, the indications of TAVR expand from inoperative and high risk patients to the intermediate risk patients; second, although the Consensus recommended pre-dilation with balloon of modest size, the necessity of pre-dilation is under debate; third, the Consensus pointed out main complications of TAVR, and the main strategies to avoid complications are careful pre-procedural analysis and development of new device; fourth, our experts had made outstanding contribution to TAVR in the treatment of patients with bicuspid aortic valve, which still has many problems to be solved urgently.

          Release date:2018-02-26 05:32 Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品