        • Experiences of Endovascular Repair in Treatment for Aortic Dissecting Aneurysm(Report of 15 Cases)

          目的 總結腔內修復術治療主動脈夾層的經驗。方法 選擇2011年7月至2013年1月期間我院住院的胸主動脈夾層患者15例,術前均采用CTA評估,全部行腔內修復術。結果 15例患者采用腔內修復手術全部成功,手術時間95~165min,(120±26) min;失血量30~160mL,(68±34) mL。10例采用經股動脈入路,5例采用經股動脈及肱動脈入路。13例單一破口者各植入支架1枚,手術全部成功。15例患者未發生截癱,無一椎基底動脈缺血癥狀,無下肢缺血改變,無傷口感染及腹股溝區淋巴瘺。2例存在Ⅱ型內漏,未經處理自行閉合。隨訪胸腹主動脈CTA掃描顯示覆膜支架均未移位,未發現植入支架后并發近端夾層者。結論 腔內修復術治療主動脈夾層是一種有效的治療方法,具有安全性高、術后并發癥少、治療效果好等優點。

          Release date:2016-09-08 10:23 Export PDF Favorites Scan
        • The effect of axis pedicle and intra-axial vertebral artery on C2 pedicle screw placement

          Objective To investigate the influence of axis pedicle and intra-axial vertebral artery (IAVA) alignment on C2 pedicle screw placement by measuring the data of head and neck CT angiography. MethodsThe axis pedicle diameter (D), isthmus height (H), isthmus thickness (T), and IAVA alignment types were measured in 116 patients (232 sides) who underwent head and neck CT angiography examinations between January 2020 and June 2020. Defined the IAVA offset direction by referencing the vertical line through the center of C3 transverse foramen on the coronal scan, it was divided into lateral (L), neutral (N), and medial (M). Defined the IAVA high-riding degree by referencing the horizontal line through the outlet of the C2 transverse foramen, it was divided into below (B), within (W), and above (A). The rate of pedicle stenosis, high-riding vertebral artery, and different IAVA types were calculated, and their relationships were analysed. Simulative C2 pedicle screws were implanted by Mimics 19.0 software, and the interrelation among the rates of pedicle stenosis, high-riding vertebral artery, IAVA types, and vertebral artery injury were analyzed. ResultsThe rate of C2 pedicle stenosis was 33.6% (78/232), and the rate of high-riding vertebral artery was 35.3% (82/232). According to the offset direction and the degree of riding, IAVA was divided into 9 types, among which the N-W type (29.3%) was the most, followed by the L-W type (19.0%) and the L-B type (12.9%), accounting for 60.9%. The vertebral artery injury rate of simulative implanted C2 pedicle screws was 35.3% (82/232). The vertebral artery injury rate in patients with pedicle stenosis and high-riding vertebral artery was significantly higher than that who were not (P<0.001). The rate of pedicle stenosis, high-riding vertebral artery, and vertebral artery injury were significantly different among IAVA types (P<0.001), and M-A type was the most common. ConclusionVertebral artery injury is more common in pedicle stenosis and/or high-riding vertebral artery and/or IAVA M-A type. Preoperative head and neck CT angiography examination has clinical guiding significance.

          Release date:2022-08-04 04:33 Export PDF Favorites Scan
        • Clinical application of computed tomographic angiography in predicting the vascular pedicle length of the proximally-based anterolateral thigh flap

          Objective To explore the reliability and effectiveness of prediction of the pedicle length of the proximally-based anterolateral thigh (pALT) flap which was used to repair the defects following the resection of various malignant tumors using computed tomographic angiography (CTA). Methods The clinical data of 12 patients who met the selection criteria by using pALT flap to repair wounds left after malignant tumor resection between June 2015 and December 2020 were retrospectively analyzed. There were 5 males and 7 females; the age ranged from 16 to 80 years, with an average age of 54.4 years. After tumor resection, the soft tissue defect ranged from 15 cm×5 cm to 30 cm×12 cm; defect sites included 4 cases of lower abdomen, 3 cases of groin, 2 cases of thigh, and 3 cases of buttocks. Preoperative CTA was used to obtain the location information of the descending branch of the lateral femoral circumflex artery and its perforators by maximum density projection, and the length of the pedicle of pALT flap was estimated. Fasciocutaneous flap (5 cases) or myocutaneous flap (7 cases) were cut during operation to repair the defect, and the size of flap ranged from 20 cm×7 cm to 30 cm×12 cm. The donor site of thigh was directly sutured (11 cases) or repaired with skin graft (1 case). Bland-Altman analysis was used to detect the consistency between the pALT flap vascular pedicle length estimated by CTA and the pALT flap vascular pedicle length actually obtained during operation. ResultsOne case had distal blood supply disturbance of the flap and was repaired with skin graft after debridement; the remaining 11 flaps survived. All donor and recipient incisions healed by first intention. All 12 cases were followed up 1-12 months, with an average of 4.3 months. One patient died of pelvic tumor recurrence at 6 months after operation, and no tumor recurrence was found in the other patients. Preoperative CTA estimated that the length of pALT flap vascular pedicle was 9.3-24.7 cm, with an average of 14.7 cm; the actual length of pALT flap vascular pedicle was 9.5-25.0 cm, with an average of 14.8 cm. Bland-Altman analysis showed that there was no significant difference between the pALT flap vascular pedicle length estimated by CTA before operation and the pALT flap vascular pedicle length actually obtained during operation, and the average difference was 0.1 (95% consistency limit: –0.89, 0.74), indicating that they had good consistency. ConclusionCTA can be accurately used to localize the perforator and predict the possible pedicle length of the pALT flap. When performing a pALT flap surgery, preoperative CTA is helpful for surgeons to make a preliminary assessment of the difficult of the operation. The time for exploration of perforators and dissection of the vascular pedicle, and complications can be reduced, and the safety of the operation can be improved.

          Release date:2022-03-22 04:55 Export PDF Favorites Scan
        • Evaluation of Peripancreatic Vascular Invasion of Pancreatic Carcinoma by Multi-Slice CT Angiography

          ObjectiveTo explore the value of multi-slice CT angiography (MSCTA) in peripancreatic vascular invasion of pancreatic carcinoma. MethodsThirty-eight patients with pancreatic carcinoma were detected by MSCTA technology before operation. The peripancreatic vascular invasion of pancreatic carcinoma was evaluated by multi-planar reconstruction (MPR) and maximum intensity projection (MIP) combined with axial image, and compared with the surgical results. ResultsThe MSCTA results showed that there were 12 patients (31.6%) with vascular invasion in 38 patients with pancreatic carcinoma, and the surgical results showed that there were 16 patients (42.1%) with vascular invasion. There was a b fit goodness of two results (kappa=0.665, P=0.000). The sensibility and specificity of MSCTA was 68.8% (11/16) and 95.5% (21/22), respectively. ConclusionsMSCTA technology has a high correct rate in evaluation of peripancreatic vessel encroached by pancreatic carcinoma, the MSCTA result has a b consistency to the surgical result. It has a value of clinical application in evaluation of peripancreatic vessel encroached by pancreatic carcinoma.

          Release date:2016-09-08 10:45 Export PDF Favorites Scan
        • APPLICATION OF DIGITAL TECHNOLOGY IN ANTEROLATERAL THIGH FLAP FOR REPAIRING WOUNDS OF HAND AND FOOT

          ObjectiveTo investigate the effectiveness of digital technology in repairing wounds of the hand and foot with anterolateral thigh flap. MethodsBetween September 2013 and September 2014, 16 cases of wounds of the hand and foot were treated with the anterolateral thigh flap. There were 10 males and 6 females, with an average age of 31 years (range, 20-52 years). The causes included traffic accident injury in 8 cases, crushing injury by machine in 6 cases, burning injury in 1 case, and animal biting injury in 1 case. The locations of soft tissue defect were the dorsum of the foot in 5 cases, the ankle in 4 cases, the planta pedis in 1 case, and the hand and forearm in 6 cases. The time was 2 hours to 45 days from injury to hospitalization (mean, 14.3 days). All defects were associated with exposure of bone and tendon. The size of wound was from 9.0 cm×4.0 cm to 29.0 cm×8.5 cm. CT angiography (CTA) was performed before operation, and the appropriate perforator as well as the donor site was selected. Then the Mimics15.0 software was used to reconstruct the data of CTA so as to locate the main perforators, design the three-dimensional models of the anterolateral thigh flap, and simulate operation. The flap was obtained according to preoperative plan during operation. The size of flaps varied from 11 cm×5 cm to 31 cm×10 cm. The donor sites were sutured directly in 14 cases and were repaired by free skin graft in 2 cases. ResultsThe lateral femoral circumflex artery identified by Mimics15.0 software before operation, as well as the starting position of its descending branch, the blood vessel diameter at start site, vascular distribution, the maximum cutting length of the vascular pedicle were consistent with the actual observation during operation. All flaps were harvested and were used to repair defect smoothly. Vascular crisis occurred in 1 flap after operation, and the other flaps survived successfully. The wounds and the incisions obtained healing by first intention, and grafted skin survived completely. All cases were followed up 6-17 months (mean, 9 months). Fifteen flaps had good shape;but a second-stage operation was performed to make the flap thinner in 1 case. At last follow-up, the results were excellent in 3 cases, good in 2 cases, and fair in 1 case according to total active motion (TAM) in 6 cases of hand and forearm injury;the results were excellent in 5 cases, good in 3 cases, and fair in 2 cases according to American Orthopaedic Foot and Ankle Society (AOFAS) in 10 cases of foot injury. The total excellent and good rate was 81.25%. ConclusionThe preoperative individualization design of the flap can be realized through CTA digital technology and Mimics15.0 software;it can reduce the operation risk.

          Release date: Export PDF Favorites Scan
        • APPLICATION OF TEMPORARY BALLOON BLOCKING TECHNIQUE IN BONE TUMORS SURGERY UNDER THE AID OF CT ANGIOGRAPHY

          ObjectiveTo study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. MethodsA retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. ResultsThe CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545±0.248) cm and (1.060±0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818±1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1 800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months (mean, 21 months). According to Enneking standard, the results were excellent in 9 cases, good in 20 cases, fair in 5 cases, and poor in 2 cases at 3 months after operation. There were 10 cases of dysfunction of urination and defecation, 2 cases of tumor recurrence, and 3 cases of death after surgery. ConclusionCTA and three-dimensional reconstructions technique can accurately measure the external diameter of aortaventralis and arteria iliaca communis and the distance between low renal artery and abdominal aortic bifurcation and offer great help to choose appropriate balloon and locate the balloon during surgery. The balloon blocking technique under the assistance of CTA can obviously reduce intraoperative blood loss and tumor recurrence, supply a clear view in surgery and shorten the operation time.

          Release date: Export PDF Favorites Scan
        • Diagnostic Value and Clinical Application of Multi-slice Spiral CT Angiography in Aortic Dissection

          目的 探討多層螺旋CT血管造影(CTA)在主動脈夾層中的診斷價值及臨床應用。 方法 回顧性分析2010年2月-2011年4月35例行CTA檢查的主動脈夾層患者,所有患者原始數據在圖像后處理工作站采用多平面重建、容積再重建、最大密度投影等方法進行主動脈成像。由2名有經驗的放射科副主任醫師進行診斷。 結果 35例均可明確顯示主動脈夾層的真假腔、內膜片及破裂口部位。Ⅰ型12例,Ⅱ型3例,Ⅲ型20例;累及左鎖骨下動脈5例,左頸總動脈2例,無名動脈2例,腹腔干3例,腸系膜上動脈4例,左腎動脈3例,右腎動脈2例,右髂總動脈受累6例,左髂總動脈受累8例,其中雙側髂總動脈均受累4例;合并動脈瘤3例;壁內血腫4例;所有患者均顯示了單一或多發破口。 結論 CTA及圖像后處理技術能快速、準確地診斷主動脈夾層,為臨床治療方案選擇提供重要的影像學依據。

          Release date:2016-09-08 09:16 Export PDF Favorites Scan
        • Model reconstruction and morphological observation of internal carotid artery siphon and ophthalmic artery in non-arteritic anterior ischemic optic neuropathy patients

          ObjectiveTo observe the morphological characteristics of internal carotid artery (ICA) siphon and ophthalmic artery (OA) in patients with non-arteritic anterior ischemic optic neuropathy (NAION) based on CT angiography (CTA) three-dimensional reconstruction of ICA siphon and OA models. MethodsA retrospective cohort study. From January 2017 to January 2019, 26 patients with 31 eyes (NAION group) who were diagnosed with NAION by ophthalmic examination at Beijing Friendship Hospital, Capital Medical Universitywere included in the study. Among them, there were 11 males with 13 eyes, and 15 females with 18 eyes; the age was 67.52±6.30 years old. Nineteen eyes of 19 non-affected contralateral eyes were selected as the contralateral eye group. Among them, there were 9 males with 9 eyes and 10 females with 10 eyes; the age was 65.95±5.66 years old. Twenty-six eyes of 26 age- and sex-matched subjects with normal fundus examination during the same period were selected as the normal control group. All subjects underwent best corrected visual acuity (BCVA), intraocular pressure, fundus photography and CTA examination. The data obtained from CT scans were reconstructed by 3D model, and the anatomical morphology of ICA siphon was divided into U-shape, V-shape, C-shape and S-shape; the diameter of ICA siphon portion and the diameter at the beginning of OA were measured. One-way analysis of variance was used to compare the diameter of the OA at the beginning of the OA and the diameter of the ICA siphon between the three groups of eyes. ResultsThe diameters at the beginning of OA in the NAION group, the contralateral eye group, and the normal control group were 1.17±0.20, 1.34±0.17, and 1.39±0.15 mm, respectively, and the differences among the three groups were statistically significant (F=12.325, P<0.05); there was no significant difference between the contralateral eye group and the normal control group (P=0.310). In the NAION group, the anatomical morphology of the ICA siphon was U-shaped and V-shaped in 20 (64.52%) and 8 (25.81%) eyes respectively, and S and C-shaped in 3 eyes (9.67%); in the contralateral eye group, in the control group, the ICA siphon shape of the eyes examined was U-shaped and V-shaped, and S-shaped and C-shaped were rare. The diameters of the ICA siphons in the NAION group, the contralateral eye group, and the normal control group were 3.50±0.69, 3.22±0.59, and 3.55±0.54 mm, respectively. There was no significant difference between the three groups (F=1.860, P=0.163). ConclusionU-shaped and V-shaped ICA siphons are more common in NAION-affected eyes; the diameter of the starting point of OA is significantly reduced.

          Release date:2022-08-16 03:23 Export PDF Favorites Scan
        • A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap

          Objective To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps. Methods Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient’s satisfaction with the appearance of the skin flap. Results The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods (P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods (P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture, with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9. Conclusion CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.

          Release date: Export PDF Favorites Scan
        • Effectiveness of innervated medial plantar flap for reconstruction of soft tissue defects following foot tumor resection

          Objective To evaluate the effectiveness of the innervated medial plantar flap for reconstructing soft tissue defects, particularly in the weight-bearing zone, after resection of foot tumors. MethodsA retrospective analysis was conducted on 12 patients with malignant skin and soft tissue tumors of the foot treated between October 2023 and December 2024. The cohort included 8 males and 4 females, aged 42-67 years (mean, 57.5 years). Tumor types comprised malignant melanoma (5 cases), squamous cell carcinoma (4 cases), arsenical keratosis (2 cases), and tumor-induced osteomalacia (1 case). Soft tissue defects located in the heel weight-bearing region in 10 cases and non-weight-bearing ankle region in 2 cases, with defect sizes ranging from 4.0 cm×3.0 cm to 6.0 cm×4.0 cm. Preoperative photon-counting CT angiography (PC-CTA) was performed to assess the medial plantar artery and its perforators. All patients underwent radical tumor resection with confirmed negative margins. The resulting defects were reconstructed using a innervated medial plantar flap incorporating sensory branches of the medial plantar nerve. The flap donor site was covered with a split-thickness skin graft harvested from the ipsilateral inguinal region. Results The operation was successfully completed in all 12 patients. All flaps survived completely without vascular compromise, partial necrosis, or total loss. Incisions healed primarily without dehiscence or infection. Minor skin graft necrosis occurred at the donor site in 3 patients, which healed within 2-3 weeks with routine dressing changes. No donor site complication (e.g., tendon or nerve injury) occurred. Patients were followed up 2-16 months (mean, 10.3 months). At last follow-up, there was no tumor recurrence. Flaps exhibited good color and texture match with surrounding tissue, restored sensation, and all feet achieved normal weight-bearing activity. Conclusion The innervated medial plantar flap, precisely designed based on PC-CTA localization, provides reliable blood supply and effective sensory restoration. It is an ideal method for reconstructing soft tissue defects after foot tumor resection, especially in the heel weight-bearing region.

          Release date:2025-09-01 10:12 Export PDF Favorites Scan