Objective To investigate application of medical digital imaging systems and computer technologies in orthpedics. Methods The main computer-assisted surgery systems comprise the four following subcategories. Results ①A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localisers). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineationof bone contours). ②In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. ③A system that provides aid in decisionmaking, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgicalnavigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc.). And ④ A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. Conclusion It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.
ObjectiveTo investigate the application and technical essentials of computer-assisted navigation in the surgical management of periacetabular fractures and pelvic fractures.
MethodsBetween May 2010 and May 2011, 39 patients with periacetabular or anterior and posterior pelvic ring fractures were treated by minimally invasive fixation under computer-assisted navigation and were followed up more than 2 years, and the clinical data were analyzed retrospectively. There were 21 males and 18 females, aged 15-64 years (mean, 36 years). Fractures were caused by traffic accident in 23 cases, crush injury in 6 cases, and falling from height in 10 cases. Of them, 6 cases had acetabular fractures; 6 cases had femoral neck fractures; 18 cases had dislocation of sacroiliac joint; and 15 cases had anterior pelvic ring injuries. All patients were treated with closed or limited open reduction and screw fixations assisted with navigation.
ResultsEighty-nine screws were inserted during operation, including 8 in the acetabulum, 18 in the neck of the femur, 33 in the sacroiliac joint, and 30 in the symphysis pubis and pubic rami. The mean time of screw implanted was 20 minutes (range, 11-38 minutes), and the average blood loss volume was 20 mL (range, 10-50 mL). The postoperative pelvic X-ray and three dimensional CT scan showed good reduction of fractures and good position of the screws. No incision infection, neurovascular injury, or implant failure occurred. All patients were followed up 27-33 months with an average of 29.6 months. The patients could walk with full weight loading at 6-12 weeks after operation (mean, 8 weeks); at last follow-up, the patients could walk on the flat ground, stand with one leg, and squat down, and they recovered well enough to do their job and to live a normal life.
ConclusionMinimally invasive fixation under computer-assisted navigation may be an excellent method to treat some specific types of periacetabular and anterior and posterior pelvic ring fractures because it has the advantages of less trauma and blood loss, lower complication incidence, and faster recovery.
Objective To investigate effectiveness of applying the Bone Morphingbased image-free computer-assisted system for the ligament balancing managementin the total knee arthroplasty (TKA). Methods Between November 2002 and June 2003, twenty-one posterior stabilized total knee prostheses (Ceraver, France) were implanted in 21 patients using the Bone Morphing based image-free Ceravision system.This cohort included 5 men and 16 women with an average age of 72.4 years, two undergoing high tibial osteotomy and 1 undergoing distal femoral osteotomy before. The preoperative deviation was measured by the full-length AP X-rays. The knees were in varus deviation in 14 patients and in valgus deviation in 7 patients, with an average of 2.36°(varus 13°-valgus 13°). The frontal X-rays ofthe knee were assessed, the mean value of the varus force-stress test was 8.47°(varus 2°-varus 20°), and the mean value of the valgus forcestress test was 3.63°(varus 7°-valgus 12°). Results With the Ceravisionrecorded data, the intraoperative alignment was assessed, the mean lower limb axis was 3.33°(varus 12°-valgus 10°),and compared with the preoperative data, the difference was significant (Plt;0.05); the mean value of the varus force-stress test was 6.47°(varus 0°-varus 24°), the mean value of the valgus force-stress test was 4.32°(varus 8°- valgus 15°), and compared with the preoperative data, the difference was significant (Plt;0.05). The post-prosthetic alignment on Ceravision with a deviation of 0.175°(varus 2°- valgus 3°) was compared with the postoperative alignment by the full-length AP X-rays, with a deviation of 0.3°(varus 3.5°-valgus 1.5°), the difference wasn’t significant(Pgt;0.05).The clinical check-up performed 3 months after operation showed that the average range of movement (ROM) was 115°(105-130°), the mean frontal laxity was 0.27 mm(0.2-0.5 mm). The femoral and tibial components were implanted in the satisfactory 3 dimensional position without ligament imbalance in all the patients, andthere were no instability or patella complications.Conclusion Utilization of the Bone Morphing based image-free computer-assisted system can achieve an accurate component 3 dimensional alignment, optimal bone resection, optimal control of surgical decision in releasing the soft tissues, rotating the femoral component to gain an extension/flexion rectangular gap, and managing theligament balancing so as to achieve a satisfactory initial clinical outcome. This system can be routinely used in the TKA.
ObjectiveTo observe the asynchrony patterns between left and right lungs in smokers and non-smokers,to assess the role of vibration response imaging(VRI) in the early detection and evaluation of smoking-related lung abnormalities.
MethodsData were collected as follows:(1)past history and smoking history were collected;(2)exhaled CO test to confirm smoking status was performed;(3)VRI test was performed and the curve of Breath Energy Unit(BEU)was drawn,which is an energy versus time graph of the breath energy.The asynchrony between left and right lungs was derived from this graph;(4)pulmonary function test was performed.In the end,26 villagers with normal spirometry findings were included in the study.The subjects were divided into an ever-smoking group and a never-smoking group.
ResultsThe BEU lung asynchrony was 2.0(3.0) frame in the never-smoking group,and 2.0(3.0) frame too in the ever-smoking group.Rank sum test showed that there was no significant difference(Z=-0.29,P=0.77) between the never-smokers and the ever-smokers in the lung asynchrony.Rank correlation analysis suggested that in the ever-smoking group,smoking index and BEU asynchrony had significant correlation(r=0.61,P=0.03).In the never-smoking group,the coefficient of passive smoking index and lung asynchrony was 0.52(P=0.07).The P value of the coefficient between passive smoking index and lung asynchrony was nearly 0.05,scatter between them could be seen a presence of a certain trend.
ConclusionThe lung asynchrony in VRI has dose-effect relationship with ever-smokers' smoking level(smoking index).Thus,the lung abnormalities in VRI caused by the exposure to passive smoking is maybe the same as the abnormalities caused by direct smoking.
Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.
Objective To achieve threedimensional (3D) contour image of boneand articular cartilage for fabricating custommade artificial semiknee joint as segment bone allograft.Methods The distal femora of human and pig were scanned with Picker 6000 spiral X-ray computed tomography with 1.0 mm thick slice. The data obtained were treated in Voxel Q image workstation for 3D reconstruction with volume rendering technique. After being downloaded to personal computer at 0.1 mm interval, the transaxial 2D image data were converted into 2D digitized contour data by using image processing software developed by the team. The 2D digitized data were inputted into image processing software of Surfacer 9.0 (Imageware Company, USA), then the 3D wire frame and solidimages of femoral condyle were reconstructed. Subsequently, based on the clinical experience and the requirement of the design of artificial knee joint, the 3Dcontour image of bone or articular cartilage was extracted from the surrounding.Results The 3D contour image of bone or articular cartilage presented was edited and processed easily for the computer aided design(CAD) of custom-madeartificial knee joint.Conclusion The 3D contour image of boneand articular cartilage can be obtained by spiral CT scanning, and the digitized data can beapplied directly to CAD of custom-made artificial joint and subsequently rapidprototyping fabricating. In addition, the reconstruction method is simple and can be applied widely to clinical implant fabricating practice of dentistry and orthopaedics.
Objective To improve the accuracy of the acetabular component placement using the nonimage based surgical navigation system. Methods Twenty-three patients (14 males, 9 females; age, 28-55 years;26 hips)with hip disease underwent the total hip arthroplasty (THA) using the nonimage based surgicalnavigation system from February 2004 to April 2006. Rheumatoid arthritis was found in 3 patients (3 hips), necrosis of the femoral head in 6 patients (6 hips), and osteoarthritis in 14 patients (16 hips). All the patients were randomly divided into the following 2 groups: the navigated group (11 patients, 13 hips), treated by THA using the nonimage based surgical navigation system; and the control group (12 patients, 13 hips), treated by the traditional THA. According to thedesign of the study, the acetabular component was placed in the best inclination angle (45°) and the anteversion angle (15°). The postoperative component position was examined. Results No fracture, dislocation, infection or injury to the sciatic nerve was found. In the navigated group, the inclination and the anteversion reached 15.4±1.4° and 45.5±1.3°, respectively. In the control group,the inclination and the anteversion were 13.9±7.6° and 43.7±6.4°, respectively. The inclination difference was considered statistically significant (Plt;0.01). All the patients were followed up for 10-40 months,averaged 26 months. In the navigated group, the postoperative average Harris hip score was 95 (range,85-110), with an excellent result in 11 hips and a good result in 2 hips. In the control group, the postoperative average Harris hip score was 92 (range,75-110), with an excellent result in 9 hips, a good result in 3 hips, and a fair result in 1 hip. The Harris hip score difference was considered statistically significant (Plt;0.05). There was a significantly better result obtained in the navigated group than in the control group. Conclusion The acetabular component can be implanted accurately by the nonimage based surgical navigation system, which can reduce the incidence of the loosening of the prostheses and has an important value in clinical practice.
Objective To review the CT appearances and important differential diagnoses of various primary and secondary mesenteric neoplasms. Methods By describing the mesenteric anatiomy and major routes for the dissemination of metastatic mesenteric tumors, the article presents both the common and rare types of various primary and secondary mesenteric neoplasms, and addresses the characteristic CT appearances and important aspects of the differential diagnosis. Results CT study, especially the multislice spiral CT (MSCT), along with the clinical history and other related information, can nicely depict various mesenteric tumors and well differentiate them from infectious, inflammatory or vascular processes affecting the mesentery. Conclusion CT is the imaging method of choice for the evaluation of tumors of small bowel mesentery.
Objective To investigate the significance of three dimensional (3D) visualization and virtual surgery system in liver transplantation surgery. Methods Two patients suffered from cholangiolithiasis were scanned by 64 slice helical-CT on livers and the data were collected. Man-made segmentation and true up on the image from the data were carried out. 3D moulds of the liver and the intrahepatic vessels were reconstructed by VTK software respectively. And then, the moulds were imported to the FreeForm Modeling System for modifying. At last, auxiliary partial orthotopic liver transplantation was simulated with the force-feedback equipment (PHANTOM). Results ①It had greatly verisimilar image for the reconstructed 3D liver moulds with artery, vein, portal vein and bile duct; By liver seeing through, it had high fidelity and b 3D effect for the intrahepatic artery, vein, portal vein and bile duct, and their spatial disposition and course and correlationship were shown clearly. ②In the virtual surgery system, the virtual scalpel could be manipulated on 3D liver mould with PHANTOM. The simulating effect was the same as the clinic operation for auxiliary partial orthotopic liver transplantation. Plane visualization of hepatic resection and intrahepatic vessel cutting was achieved by adjusting the transparency of the resection part. Life-like could be felt and power feeling could be touched during virtul operation. Conclusion ①The visualized liver mould reconstructed is 3D and verisimilar, and it is helpful to design reasonable scheme for liver transplantation. ②It not only can improve the surgical effect and decrease the surgical risk, but also can reduce the complications and enhance the communication between doctor and patient through designing surgical plan and demonstrating visualized operation before surgery. ③Visualized liver transplantation surgery is helpful for medical workers to train and study.
Objective
To investigate the clinical efficacy of computer-assisted cannulated screw internal fixation system based on error correction method for femoral neck fractures.
Methods
A retrospective analysis was made on the clinical data of 20 femoral neck fracture patients treated by computer-assisted cannulated screw internal fixation system based on error correction method between January 2014 and October 2015 (trial group), and 36 femoral neck fracture patients undergoing traditional manual surgery with closed reduction by cannulated screw fixation in the same period (the control group). There was no significant difference in gender, age, injury cause, side of fracture, types of fracture, and time from injury to operation between 2 groups (P>0.05). The operation time, intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion, fracture healing time, fracture healing rate, and Harris hip score were compared between 2 groups.
Results
All incisions healed by first intention after operation, and no complication of blood vessel and nerve injury occurred. The operation time of trial group was significantly longer than that of control group (t=2.290,P=0.026), however, the intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion of trial group were significantly less than those of control group (t=–10.650,P=0.000;t=18.320,P=0.000;t=–16.625,P=0.000). All patients were followed up 12-18 months (mean, 14.7 months). X-ray films showed that fracture healing was obtained in 2 groups, showing no significant difference in fracture healing time between 2 groups (t=0.208,P=0.836). No complication of ischemic necrosis of femoral head occurred during follow-up period. At last follow-up, the Harris hip score was 87.05±3.12 in trial group and was 86.78±2.83 in control group, showing no significant difference (t=0.333,P=0.741).
Conclusion
Computer-assisted cannulated screw internal fixation surgery based on error correction method for femoral neck fractures is better than traditional manual surgery in decreasing intraoperative radiation and surgical trauma during operation.