1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Hernia" 21 results
        • ADVANCES IN CLINICAL APPLICATION OF HERNIOPLASTY BY HIGH MOLECULAR MATERIAL

          Objective To study the advances in clinical application of hernioplasty by high molecular material. Methods The literature in the recent years on the advances of hernioplasty by high molecular material was reviewed. Results At present time many operative techniques of hernioplasty by high molecular material have been developed. The representative techniques were ①Rives-Stoppa′s mesh inlay hernioplasty; ②Lichtenstein′s tesion-free herniorrhaphy; ③mesh plug hernioplasty; ④Gilbert′s sutureless hernioplasty; ⑤laparoscopic inguinal hernioplasty. The reparing high molecular material was divided into absorbable and unabsorbable material, the former included polyglycolic-acid and polyglaction, the later consists of polypropylene polyester and expanded polytetrafluoroethylene.Conclusion The clinical application of henioplasty by high molecular material is increasing. According to the hernia type and patient condition, excellent outcome will be achieved by the application of proper repairing method and repair material.

          Release date:2016-09-08 01:59 Export PDF Favorites Scan
        • Clinical Study on Benifits of Different Hernioplasties in Inguinal Hernia

          【Abstract】ObjectiveTo evaluate the therapeutic benefits of three styles of hernioplasties such as the traditional hernioplasty, the mesh only hernioplasty and the plug amp; mesh hernioplasty. MethodsThe traditional hernioplasty in 534 cases(583 sides), the mesh only hernioplasty in 57 cases(60 sides) and the plug amp; mesh hernioplasty in 51 cases(54 sides) were performed. The comparing studies on the operative time, the postoperative complications, the recurrent rate and so on were analyzed. ResultsThe average operative time of the traditional styles group was (34.26±4.56) min, which was significantly shorter than the mesh only group 〔(40.35±6.24) min, P<0.05〕 and the plug amp; mesh group 〔(49.12±8.69) min, P<0.01〕 respectively. This significant difference between the mesh only group and the plug amp; mesh group was also identified (P<0.05). Postoperative complications in the traditional styles group, the mesh only group and the plug amp; mesh group were 1.12%, 1.75% and zero,respectively (Pgt;0.05). Recurrent rate in the traditional styles group was 5.99%(32/534), which was significantly higher than that of the mesh only and the plug amp; mesh group (no recurrence). The average hospitalizing time in the traditional styles group, the mesh only group and the plug amp; mesh group was (7.11±3.06) days,(5.38±2.53) days and (6.19±3.61) days, respectively, in which there was no significant difference among groups. The activityrecovering time in the traditional styles group was (16.98±4.35) days, which was significantly longer than (7.26±2.46) days in the mesh only group and (8.02±3.35) days in the plug amp; mesh group. Conclusion The mesh only hernioplasty or the plug amp; mesh hernioplasty have a lower recurrent rate comparing with that in the traditional hernioplasty, which should be much more popularly applied in the treatment of inguinal hernia.

          Release date:2016-09-08 11:54 Export PDF Favorites Scan
        • Reoperation of Recurrent Incisional Hernia after Mesh Repair with Prosthetic Patch

          Objective To summarize the experiences and methods on reoperation of recurrent incisional hernia after mesh repair with prosthetic patch. Methods Sixteen patients who got reoperation from January 2007 to December 2010 because of recurrent incisional hernia after mesh repair were analyzed retrospectively. Results All patients received prosthetic patch repair for reoperation. Thirteen patients received new mesh repair accompanied with old mesh removal, repair conducted by suturing new mesh with old mesh together in two patients, and repair performed by new mesh overlapping the old mesh in one patient. All patients recovered with primary wound healing. Fluid upon the mesh occurred in 3 patients and cured by percutaneous puncture and pressure dressing. Postoperative hospital stay was 7 to 16 days and the average 9 days. The drainage was removed 2 to 7 days after operation and the average was 4 days. All the 16 patients were followed up. And during a follow-up range of 5 to 36 months and the average 20 months, there was slight foreign body sensation in one patient, no chronic pain in wound area occurred. And no abdominal wall hernia recurrence occurred. Conclusions Reoperation of recurrent incisional hernia after mesh repair need to consider the recurrent position, material of the previous mesh, and the previous surgical methods, and should select appropriate prosthetic patch and surgical procedure, then could gain satisfied results.

          Release date:2016-09-08 10:36 Export PDF Favorites Scan
        • SURGICAL TREATMENT OF INTRARECTAL PROCTOPTOSIS ACCOMPANYING WITH PELVIC FLOOR HERNIATION(REPORT OF 11 CASES)

          Objective To explore the operative result of intrarectal proctoptosis accompanying hernia of pelvic floor due to common outlet obstructive constipation(OOC).MethodsEleven cases of intrarectal proctoptosis with of pelvic floor surgically treated were analysed. Results In a week following operation, 9 of 11 patients’ symptoms disappeared, the other 2 cases recovered after 3 months, functional exercise. Conclusion Functional rectal suspension combined with repair of pelvic, partial sigmoidectomy, surgical elevation of pelvic floor and hysteropexy are highly effective in alleviating symptoms in patients with intrarectal proctoptosis accompanying pelvic floor herniation.

          Release date:2016-08-28 05:29 Export PDF Favorites Scan
        • Analysis on Curative Effect of Laparoscopic Repair for Suprapubic Incisional Hernia Using Composite Patch

          Objective To summarize the surgical technique and curative effect of laparoscopic repair for suprapubic incisional hernia using composite patch. Methods The clinical data of 25 cases performed laparoscopic repair of suprapubic incisional hernia using composite patch from March 2007 to October 2010 were reviewed retrospectively. There were 13 males and 12 females, and aged 35-83 years (median age was 52 years). Among them 2 patients were recurrences. The distance between the lower margin of hernia defect and pubic arc was less than 5 cm. The composite patch was fixed to the abdominal wall using spiral tacks (Protack) in direct vision. The lower margin of the patch was lower to the pubic arc in 2 cm, and to be fixed to the pubic arc and bilateral pectineal ligament, and it should be extended. Results Laparoscopic repair were successfully performed in all patients without convert to open repair. The max diameter of the hernia ring was 6.1-12.5cm and the average was 9.5 cm. The average operating time was 128 min (ranging from 90 to 180 min). And the total complication rate was 28% (7/25), including bladder damage during operation in 1 case, wound seroma upon the patch in 4 cases and cured by aspiration, pain in the operative area and disappeared within one month without intervention in 1 case. Twenty-two patients were followed-up with a follow-up rate of 88%. During a follow-up range of 6-48 months(average 30 months), one case recurrence occurred in 2 months after the repair with the recurrent rate of 4%. Conclusions Laparoscopic repair of suprapubic incisional hernia is a safe and feasible technique, and the patch should cover and exceed the margin of the defect for 5 cm in all direction. The lower margin of the patch should be fixed to the bilateral pectineal ligament so as to strengthen the fix, and lower the recurrence rate.

          Release date:2016-09-08 10:37 Export PDF Favorites Scan
        • THE EFFECTIVENESS OF PROLENE PATCH IN HERNIA PREVENTION FOLLOWING HAR VESTING RECTUS ABDOMINIS MYOCUTANEOUS FLAP

          OBJECTIVE: To investigate the effectiveness of polypropylene path (Prolene) in hernia prevention following harvesting of rectus abdominis is myocutaneous flap. METHODS: From November 1999 to October 2000, Prolene patches were applied in 26 cases to repair the anterior rectus sheath following harvesting free rectus abdominis myocutaneous flap. Data concerning each case included size of rectus flap, defect of rectus sheath, size of patch used, wound healing and complications. RESULTS: Prolene patch showed good biocompatibility with abdominal tissue. No foreign-body rejection occurred after operation. Seroma developed in 1 case, and was drained bedside without complication. All prolene patches healed well in the body during follow-up. Hernia formation and abdominal bulge were not observed. CONCLUSION: Prolene patch is a satisfactory material for repair of the anterior rectus sheath after harvesting free rectus abdominis myocutaneous flap.

          Release date:2016-09-01 10:21 Export PDF Favorites Scan
        • Application of Transverse Fascia in Inguinal Hernia Repair

          Objective To investigate the application of transverse fascia in inguinal hernia repair. Methods In this study, 617 patients underwent inguinal hernia repair between January 1990 and December 2005 in our hospital were included, which were divided into two groups according to different operative ways: transverse fascia method group (n=337) and Bassini method group (n=280). Then intraoperative results, postoperative complications, and rehabilitated results of patients in two groups were compared. Results Compared with Bassini method group, the patients in transverse fascia method group did not show significant difference in operative time and blood loss during operation (Pgt;0.05). The differences of severe postoperative pain, testicular swelling, the time of the body’s restore for normal activities, and recurrence rate of patients between two groups were significant (Plt;0.05), while the difference of hematoma of scrotum and infection of incisional wound (Pgt;0.05). Conclusion The strengthening of posterior wall by transverse fascia and reconstruction of inner ring is a simple and effective method for inguinal hernia repair.

          Release date:2016-09-08 10:54 Export PDF Favorites Scan
        • Application of Dexmedetomidine in Combined Spinal Epidural Anesthesia for Laparoscopic Total Extraperitoneal Hernia Repair

          ObjectiveTo observe the effects and security of dexmedetomidine in combined spinal epidural anesthesia (CSEA) for laparoscopic total extraperitoneal hernia repair (TEP). MethodsFrom January 2010 to January 2013, we selected 90 patients who were going to receive TEP surgery as our study subjects. The patients were divided into three groups:M1, M2 and M3 with 30 patients in each. The patients had left lateral position, and anesthesia was done between 3-4 lumbar epidural line. Injection of 0.5% bupivacaine 2 mL was carried out, and epidural catheter was 3-5 cm. Anesthesia plane was adjusted from the chest 4 or 6 vertebra to the sacral vertebra. The three groups of patients were treated with micro pump using dexmedetomidine given at a pre-charge of 0.5 μg/kg, and then group M1 was maintained by 0.3 μg/(kg·h), M2 by 0.5 μg/(kg·h), and M3 by 0.7 μg/(kg·h). The changes of mean arterial pressure (MAP), heart rate, respiration and pulse oximetry (SpO2) were observed at each time point, and bispectral index (BIS) monitor and Ramsay sedation score test were also conducted. ResultsThe changes of MAP, heart rate and respiration in group M1 were not obvious; the Ramsay score for group M1 was 2 to 3, and BIS value after pre-charge was 65-84. For group M2, MAP, heart rate and respiration had a slight decline; Ramsay score was 3-5 points, and BIS value was 60-79. In group M3, patients had a milder decline in their MAP and respiration; the heart rate declined obviously after receiving dexmedetomidine and one patient with severe decline of the heart rate alleviated after active treatment; Ramsay score was 5 to 6 points, and BIS value was between 55 and 75. There was little change in SpO2 in all the three groups, and the difference was not statistically significant (P>0.05). ConclusionContinuous injection of dexmedetomidine at 0.3-0.5 μg/(kg·h) in CSEA is an alternative way for anesthesia, which can effectively promote sedation and reduce pain and discomfort.

          Release date: Export PDF Favorites Scan
        • Analysis of Surgical Technique and Clinical Outcome of Laparoscopic Inguinal Hernia Repair

          Objective To explore surgical technique and clinical outcome of transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal hernia repair (TEP) in inguinal hernia repair. Methods 〗The clinical data of 23 patients underwent laparoscopic herniorrhaphy were retrospectively analyzed. Nine patients were underwent TAPP, and 14 patients underwent TEP. Results 〗None of patients was changed to open operation. Only one patient of TEP was changed to TAPP. Average operative time was (82.1±40.6) min. Blood loss was (5.7±3.0) ml. Disruption of peritoneum happened to 2 patients underwent TEP. The rate of postoperative complications was 21.7% (5/23), which included serum swelling (1 case), scrotal emphysema (2 cases), transient neurapraxia in the area of repair (1 case) and urinary retention (1 case). No chronic pain, foreign body sensation and infection were found. Average hospitalization after operation was (4.3±0.9) d. No recurrence was observed during a follow-up period of 1-15 months. Conclusion 〗Laparoscope herniorrhaphy is safe due to lower recurrence and complications. It also has the advantages of slight pain and rapid recovery.

          Release date:2016-09-08 10:57 Export PDF Favorites Scan
        • Preparation and animal experiment of a novel sirolimus drug-coated mesh

          Objective To prepare a new sirolimus drug-coated polypropylene (SRL-PP) mesh by grafting he sirolimus onto the surface of the polypropylene (PP) mesh via chemical reaction, and to apply the new mesh to animal experiment to explore its anti-adhesion properties.MethodsThe sirolimus was grafted onto the surface of the mesh by chemical reaction to prepare the SRL-PP mesh, which was compared with the PP mesh and the polyethylene glycol modified polypropylene (PEG-PP) mesh. The three groups of meshes were respectively characterized (infrared spectroscopy test, contact angle measurement), and their tensile property was measured. These meshes were implanted into the abdominal cavity of the rats respectively. The anti-adhesion properties of the new sirolimus drug-coated mesh was studied by intraperitoneal adhesion and histopathological change in rats.ResultsThe results of infrared spectrum analysis showed that there was a new absorption peak at the wavelength 1 643 cm–1 (amide group) of SRL-PP mesh, suggesting that sirolimus drug was successfully uploaded onto the surface of the mesh; the SRL-PP mesh was excellent in hydrophilicity, which provided a favorable condition for the growth of peritoneal mesothelial cells. There was no significant difference in mechanical properties between SRL-PP mesh and PP mesh or PEG-PP mesh, which provided a good mechanical guarantee for clinical application. The degree of abdominal adhesion in SRL-PP mesh group (1.00±0.58) was significantly lower than that in PP mesh group (5.17±0.69) and PEG-PP mesh group (4.00±0.58), and the tD value between SRL-PP mesh group and PP mesh group was 2.76 (P<0.05). The number of inflammatory cells and the expression of inflammatory cytokines in the adhesion tissue in SRL-PP mesh group were significantly lower than those in PP mesh group and PEG-PP mesh group.ConclusionsThe sirolimus is successfully loaded onto the surface in the PP mesh by chemical reaction. Animal experiment shows that the sirolimus drug-coated mesh can significantly reduce the abdominal adhesion of the rats, which provides a basis for clinical trial and application.

          Release date:2019-06-25 09:50 Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品