From August 1986 to October 1990, 34 cases of fractures of patella were treated by the self-designed spring Kirschner wire, in which, 25 cases were followed up for an average of 1.5 years. The excellentgood rate reached 88%. In comparing with the traditional method of treatment, it gave more secure fixation for fracture, without the need or only a short time of immobilization needed, short treatment course and satisfactory return of function.
Objective To compare the effectiveness of open reduction and internal fixation with plate and closed reduction and internal fixation with Kirschner wire (K-wire) in the treatment of intra-articular displaced calcaneal fractures in older children. MethodsA clinical data of 35 older children (37 feet) with intra-articular displaced calcaneal fractures who were admitted between November 2014 and November 2020 and met the selection criteria were retrospectively analyzed. Among them, 19 cases (20 feet) underwent open reduction and internal fixation with plate (plate group), and 16 cases (17 feet) underwent closed reduction and internal fixation with K-wire (K-wire group). There was no significant difference in gender, age, cause of injury, side and type of fracture, and time from injury to admission, and preoperative calcaneal Gissane angle and B?hler angle (P>0.05). The postoperative calcaneal Gissane angle, B?hler angle, complications, and fracture healing were compared between the two groups. The ankle function was evaluated based on the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot scoring system. Results Incision necrosis occurred in 1 foot in the plate group after operation, which healed after symptomatic treatment; the other incisions in the two groups healed by first intention. All children were followed up 12-39 months (mean, 19 months). X-ray films showed that the fractures in both groups healed; the healing time was (2.65±0.71) months in the plate group and (2.24±1.38) months in the K-wire group respectively, with no significant difference (t=1.161, P=0.253). At last follow-up, the calcaneal Gissane angle and B?hler angle returned to normal; and the difference between pre- and post-operation in the two group was significant (P<0.05), but there was no significant difference between the two groups in the difference between before and after operation (P>0.05). In the plate group, the plate was removed at 11-22 months after operation (mean, 16.8 months). At last follow-up, the AOFAS ankle-hindfoot score in the plate group was 91.2±5.1, which was significantly higher than that in the K-wire group (86.9±6.1) (t=2.316, P=0.027). The ankle function was rated as excellent in 15 feet, good in 4 feet, and fair in 1 foot in the plate group, and excellent in 14 feet and good in 3 feet in the K-wire group, and the difference between the two groups was not significant (Z=1.712, P=0.092). ConclusionFor intra-articular displaced calcaneal fracture in older children, the open reduction and internal fixation with plate and closed reduction and internal fixation with K-wire can achieve good effectiveness, but the former has better recovery of ankle function.
Objective To explore the feasibility and effectiveness of maintaining the reduction of unstable intertrochanteric fractures by Kirschner wire-fixation-cortical bone technique. Methods Forty patients with intertrochanteric fracture [AO/Orthopaedic Trauma Association (AO/OTA) type 31-A2.2] admitted between May 2015 and January 2017 and requiring closed reduction and proximal femoral nail antirotation (PFNA) were randomly divided into trial group (intraoperative Kirschner wire-fixation-cortical bone technique group, 20 cases) and control group (conventional treatment group, 20 cases). There was no significant difference in general data of gender, age, side, body mass index, cause of injury, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, and intraoperative fluoroscopy times of the two groups were recorded; the reduction quality of fracture was observed according to the corresponding relationship between medial and anterior cortex (positive, neutral, and negative support) of intraoperative fluoroscopy proposed by ZHANG Shimin, and the stability of internal fixation and fracture healing were observed; Harris score was used to evaluate the recovery of hip function at 12 months after operation. Results In the trial group, 6 cases (30%) had 2 Kirschner wires implanted less than 4 times, 7 cases (35%) had 5-8 times, and 7 cases (35%) had 9 times or more. There was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05), but the blood transfusion volume and intraoperative fluoroscopy times in the trial group were significantly less than those in the control group (P<0.05). Both groups were followed up 13-21 months, with an average of 17 months. There was no complications such as wound infection, deep venous thrombosis of lower extremities, refracture, and internal fixation-related complications. The quality of intraoperative reduction in the trial group was significantly better than that in the control group (Z=–2.794, P=0.024). The Harris score of the trial group was significantly better than that of the control group at 12 months after operation (t=2.98, P=0.01). Conclusion The use of Kirschner wire-fixation-cortical bone technique during intertrochanteric fracture closed reduction and PFNA internal fixation surgery can effectively maintain the reduction effect, reduce the number of fluoroscopy, improve the reduction quality, reduce allogeneic blood input, obtain better hip function, and do not increase the operation time and intraoperative blood loss.
ObjectiveTo summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture.MethodsBetween January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score.ResultsAll incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%.ConclusionThe procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.
ObjectiveTo compare the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures.MethodsBetween January 2017 and January 2019, 26 patients with type C patellar fractures were treated with improved Kirschner wire tension band fixation (group A), and 24 patients were treated with traditional Kirschner wire tension band fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, and side and type of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, the visual analogue scale (VAS) scores at 1 and 3 days after operation, the fracture healing time, and the occurrence of complications (skin irritation of Kirschner wires, failure of internal fixation, fracture reduction loss) were recorded, and the knee function was evaluated by Lysholm scoring standard in 2 groups.ResultsThe operation time in group A was significantly less than that in group B (t=?4.742, P=0.000). There was no significant difference in the intraoperative blood loss and VAS scores at 1 and 3 days after operation between 2 groups (P>0.05). All incisions healed by first intention. All patients were followed up 8-15 months, with an average of 11 months. The fracture healing time was (3.3±0.6) months in group A and (3.2±0.6) months in group B, showing no significant difference (t=0.589, P=0.559). At last follow-up, the knee joint function was evaluated according to Lysholm scoring standard. And there were 15 cases of excellent, 8 cases of good, and 3 cases of fair, with an excellent and good rate of 88.5% in group A; there were 8 cases of excellent, 7 cases of good, 7 cases of fair, and 2 cases of poor, with an excellent and good rate was 62.5%. The difference between 2 groups was significant (Z=2.828, P=0.005). The internal fixators were removed after the fracture healed in 2 groups. At last follow-up, no skin irritation of Kirschner wires occurred in group A, but 3 cases in group B. X-ray films reexamination showed that 5 cases of internal fixation failure and no fracture reduction loss were found in group A, while 9 cases of internal fixation failure and 1 case of fracture reduction loss in group B. The incidence of complications in group A was 19.2% (5/26), which was significantly lower than that in group B (54.2%, 13/24) (χ2=6.611, P=0.010).ConclusionCompared with the traditional Kirschner wire tension band fixation, the improved Kirschner wire tension band fixation in treatment of type C patellar fracture can shorten the operation time, reduce the incidence of complications, and benefit the functional recovery of knee joint.
Objective To investigate the curative effects of open reduction and internal fixation with Kirschner wire for Mason type-II radial head or neck fracture in children. Methods From September 2007 to June 2009, 17 cases of Mason type-II radial head or neck fracture were treated, including 11 males and 6 femals with an average age of 8.5 years (4-11 years).The locations were left side in 5 cases and right side in 12 cases. All fractures were caused by fall ing and classified as Mason type- II fracture. Two cases compl icated by radial nerve deep branch injury. The time from injury to operation was 4 hours to 5 days. All cases received open reduction and internal fixation with Kirschner wire. They were evaluated by anteroposterior and lateral radiographs and functionally by Broberg criteria. Results Wound healed primarily in all patients. According to Métaizeau criteria, the results were excellent in 15 patients and good in 2 patients, who achieved anatomical reduction. Seventeen patients were followed up for a mean time of 14 months (6-25 months). Function returned to normal in 2 cases compl icated by radial nerve deep branch injury after 6 months of operation. No compl ications of infection and nerve injury occurred. The X-ray films showed that bony heal ing was achieved in all cases; the heall ing time was 2.0-3.5 months (mean 3 months). According to Broberg criteria, the outcome was excellent in 11 cases, good in 4 cases, and fair in 2 cases, the excellent and good rate was 88.2%. Conclusion Open reduction and internal fixation with Kirschner wire has good effect, satisfactory functional recovery and less compl ication in the treatment of Mason type-II fracture of radial head or neck in children.
Objective To analyze the effectiveness comparison of external fixator combined with Kirschner wire fixation and Kirschner wire fixation in the treatment of cubitus varus deformity in children. Methods A retrospective case-control study was conducted to collect 36 children of postoperative supracondylar humerus fracture complicating cubitus varus deformity between January 2018 and July 2022. Among them, 17 cases were treated with distal humeral wedge osteotomy external fixation combined with Kirschner wire fixation (observation group), and 19 cases were treated with distal humeral wedge osteotomy and Kirschner wire fixation (control group). The baseline data including age, gender, deformity side, time from fracture to operation, carrying angle of the healthy side and preoperative carrying angle of the affected side, elbow flexion and extension range of motion, and lateral condylar prominence index (LCPI) showed no significant difference between the two groups (P>0.05). The operation time, hospitalization cost, healing time of osteotomy, postoperative complications, and the carrying angle, LCPI, and elbow flexion and extention range of motion were recorded and compared between the two groups. The elbow function was assessed by Oppenheim score at 3 months after operation and at last follow-up. Results The children in both groups were followed up 13-48 months, with an average of 26.7 months. There was 1 case of needle tract infection in the observation group and 2 cases in the control group, and no nerve injury occurred, the difference in the incidence of complication (5.88% vs 10.53%) between the two groups was not significant (χ2=0.502, P=0.593). There was no significant difference in the operation time and fracture healing time between the two groups (P>0.05); the hospitalization cost of the observation group was significantly higher than that of the control group (P<0.05). The Oppenheim score of the observation group was significantly better than that of the control group at 3 months after operation (P<0.05), but there was no significant difference in the Oppenheim score between the two groups at last follow-up (P>0.05). At last follow-up, the carrying angle of affected side significantly improved in both groups when compared with preoperative ones (P<0.05); the differences of the pre- and post-operative carrying angle of affected side and elbow flexion and extension range of motion showed no significant differences between the two groups (P>0.05), but the difference in pre- and post-operative LCPI of the observation group was significantly better than that of the control group (P<0.05). ConclusionExternal fixator combined with Kirschner wire fixation and Kirschner wire fixation both can achieve satisfactory correction of cubitus varus deformity in children, and the former can achieve better short-term functional recovery of elbow joint and reduce the incidence of humeral lateral condyle protrusion.
Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.
Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.
Objective
To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures.
Methods
Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05).
Results
There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05).
Conclusion
The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.