1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "Local" 65 results
        • Analysis of nerve excitability in the dentate gyrus of the hippocampus in cerebral ischaemia-reperfusion mice

          Ischemic stroke often leads to cognitive dysfunction, which delays the recovery process of patients. However, its pathogenesis is not yet clear. In this study, the cerebral ischemia-reperfusion model was built as the experimental object, and the hippocampal dentate gyrus (DG) was the target brain area. TTC staining was used to evaluate the degree of cerebral infarction, and nerve cell membrane potentials and local field potentials (LFPs) signals were collected to explore the mechanism of cognitive impairment in ischemia-reperfusion mice. The results showed that the infarcted area on the right side of the brain of the mice in the model group was white. The resting membrane potential, the number of action potential discharges, the post-hyperpolarization potential and the maximum ascending slope of the hippocampal DG nerve cells in the model mice were significantly lower than those in the control group (P < 0.01); the peak time, half-wave width, threshold and maximum descending slope of the action potential were significantly higher than those in the control group (P < 0.01). The time-frequency energy values of LFPs signals in the θ and γ bands of mice in the ischemia and reperfusion groups were significantly reduced (P < 0.01), and the time-frequency energy values in the reperfusion group were increased compared with the ischemia group (P < 0.01). The signal complexity of LFPs in the ischemia and reperfusion group was significantly reduced (P < 0.05), and the signal complexity in the reperfusion group was increased compared with the ischemia group (P < 0.05). In summary, cerebral ischemia-reperfusion reduced the excitability of nerve cells in the DG area of the mouse hippocampus; cerebral ischemia reduced the discharge activity and signal complexity of nerve cells, and the electrophysiological indicators recovered after reperfusion, but it failed to reach the healthy state during the experiment period.

          Release date:2024-10-22 02:39 Export PDF Favorites Scan
        • Safety of femoral nerve block for postoperative analgesia of total knee arthroplasty: an overview of systematic reviews

          Objectives To overview the systematic reviews/meta-analyses of safety of femoral nerve block (FNB) used as a postoperative analgesic technique in patients undergoing total knee arthroplasty (TKA). Methods We searched databases including The Cochrane Library, PubMed, EMbase, CNKI, WanFang Data, and VIP from inception to July, 2016. Two reviewers independently screened literature, extracted data and used AMSTAR to evaluate the methodological quality of the included studies. The major indexes used to evaluate the safety of FNB were the incidence rates of symptoms including nausea, vomiting, sedation, retention of urine, dizziness, pruritus, hypotension, falls, nenous thromboembolism and deep infection. Results A total of 12 systematic reviews/meta-analyses were included.They assessed the safety of FNB compared with local infiltration analgesia (LIA), periarticular multimodal drug injection (PMDI), epidural analgesia (EA), patient-controlled intravenous analgesia of opioids (PCA) and adductor canal block (ACB), respectively. The methodological quality of included studies were medium, with the scores between 3 to 10. The results of overview indicated that: FNB had lower incidence rates of nausea and vomiting compared with EA and PCA, but had higher than ACB. FNB had lower incidence rates of sedation and retention of urine compared with EA and PCA. FNB had lower incidence rates of dizziness compared with EA and PCA, and lower incidence rate of hypotension compared with EA. Conclusion Current evidence suggests that FNB is safer than EA and PCA. Due to the limited quantity and quality of the included studies, the above conclusions are needed to be verified by more high-quality studies.

          Release date:2017-05-18 02:12 Export PDF Favorites Scan
        • Advances in Preoperative Localization of Solitary Pulmonary Nodules for Video-assisted Thracoscopic Surgery

          Recently, the frequency of lung disease appears higher and more precise than previously estimated. Small pulmonary nodules (SPNs) are frequently detected on high-resolution computed tomography (CT) scans. For the reason of high rate of false positives by fine needle aspirate biopsy, small lung nodules often can not be confirmed by monitor or palpation with forceps. How to precisely locate and mark the nodule before the surgery is one of the most important things for video-assisted thoracoscopic surgery (VATS). We reviews the methods of location the pulmonary nodules before the surgery and analyzes the advantages and disadvantages of various methods.

          Release date: Export PDF Favorites Scan
        • The application of transversus abdominis plane block anesthesia in peritoneal dialysis catheter implantation: a randomized controlled trial

          Objective To investigate the efficacy and safety of ultrasound-guided TAP block for the anesthesia in peritoneal dialysis (PD) catheter implantation. Methods Patients with end-stage renal disease who intended to receive PD catheter implantation in the West China Hospital of Sichuan University were enrolled from April 2015 to February 2016. Those who met the inclusion criteria were randomly divided into two groups: the local filtration anesthesia (LF) group and the TAP group. The two groups got the ultrasound guided TAP block (The LF group got a shame TAP block by making the skin wheal and just inserting the needle into the TAP with the guidance of ultrasound), then the LF group received local filtration anesthesia twenty minutes later, with the TAP group had sham LF anesthesia by injection of saline at the incision subcutaneously. The anesthetist generated the random allocation sequence and performed all TAP/sham blocks according to the allocation of each patient. The patients, investigators were all blind to the allocation. The follow-up time was 3 months. The primary outcomes were the rate of alteration to general anesthesia and the VAS score during and after the surgery. The dosages of sufentanil for analgesia during and after were recorded. The satisfaction to the effect anesthesia by the operation doctors, PD catheter related complications and adverse events related to TAP block or anesthetic agent were also recorded. Statistic analysis was conducted using SPSS 19.0 software. Results A total of 36 patients were included, 12 cases in the LF group and 24 cases in the TAP group. The rate of alteration to general anesthesia in the TAP group was 4.12% and was significantly lower than that in the LF group (33.3%) (P=0.034). The VAS scores at the time points of incision of skin, division of subcutaneous tissue and anterior rectus sheath, opening the peritoneum, insertion of PDC, suture of skin, 2 hours and 24 hours after operation were significantly lower in the TAP group compared to the LF group (P values=0.001, 0.037, 0.000, 0.001, 0.029, 0.035, and 0.000, respectively). The TAP group consumed less sufentanil during the operation and showed a higher satisfaction of the operation doctors. There were no significant differences in the PD catheter related complications and adverse events between the two groups. Conclusion The ultrasound-guided TAP block can be an effective and safe anesthesia method for PD catheter implantation. Because of the limitation of small sample size of this study, a multiple center study with larger sample size is suggested.

          Release date:2017-01-18 07:50 Export PDF Favorites Scan
        • IN VITRO EXPERIMENTAL STUDY OF ADRIAMYCIN LOADED CHITOSAN DRUG DELIVERY SYSTEM

          Chitosan is a kind of biological material with good histocompatibility and gradual biodegradability in vivo. It has no toxicity or side-effect. For its gradual degradation, chitosan and adriamycin were mixed and formed drug delivery system (DDS). The release test of DDS and exudant of DDS in inhibiting OS-116 were examined in vitro. The results were as following: the DDS could release adriamycin in slow and stable way. The SO-116 inhidition rate of the exudant of the DDS on the 1st, 20th, 40th and 60th day was 58.11%, 36.48%, 24.32% and 21.62% respectively. It was concluded that the drug delivery system was a slow release system. It could maintain the concentration of adriamycin in a certain level. It was also suggested that the chitosan was a good carrier for slow release of chemotherapeutic drug in local therapy for postoperative treatment of bone tumor.

          Release date:2016-09-01 11:08 Export PDF Favorites Scan
        • STUDY ON LOCAL IMPLANTATION OF SIMVASTATIN FOR REPAIRING RABBIT RADIAL CRITICAL SIZE DEFECTS

          Objective To find an ideal material for repairing bone defect by local implanting simvastatin compounded with poly-lactic acid (PLA) into the radial critical size defects of rabbits, and to observe the reparative effect and type of bone formation induced by simvastatin. Methods Twelve 4-months-old male New Zealand white rabbits (2.3-2.8 kg) with 22 mm radial critical size defects on both sides were randomized into 4 groups (all n=3). Right side and left side of every rabbit were set as controls with each other. The left defects (experimental groups) of groups A, B, and C were implanted with cyl inder-l ike compound scaffolds containing 50, 100, and 200 mg of simvastatin (fixed with 250 mg PLA), or auto-bonegraft as group D, respectively. The right defects of groups A, B, and C were implanted with scaffolds containing only 250 mg PLA. The right defects of group D were left without any treatment. Digital X-ray images of bone defects were taken 8 and 16 weeks after operation, X-ray was scored double bl ind and X-ray pixel value was measured. Animals were euthanized16 weeks postoperatively. CT was appl ied to analyze new bone formation volume in the defects. In addition, orphologicalcharacters of new bones were observed through micro-CT and histology. Results X-ray films showed that the bone defect of each experimental side had much cloud-l ike callus, and the bone stump were not clear 8 weeks after operation; and the cortex in the defect was continuous and the medullary was recanal ized 16 weeks after operation. In control sides, the cortexes were discontinuous and the ends of fractures were sclerified. At 8 and 16 weeks after operation, the X-ray scores, pixel values and the CT volume percentage of new bone in experiment sides were all significantly higher than those in control sides (P lt; 0.05). The X-ray scores of experimental sides in groups C and D were significantly higher than those in groups A and B 8 weeks after operation (P lt; 0.05), and the X-ray scores of experimental sides in groups B and D were significantly higher than those in groups A and C 16 weeks after operation (P lt; 0.05). The X-ray pixel values of experimental sides of group B were significantly higher than those of groups A, C, and D 8 weeks after operation (P lt; 0.05). The new bone formation volume of experimental side of groups B and D was higher than that of groups A and C (P lt; 0.05), and group D was significantly higher than that of group B (P lt; 0.05). Micro-CT showed bone defects of experimental sides of group B had totally healed, with connected medullary cavities and continuous bone cortex, on the contrary bone defects of control sides of group B did not healed completely. Histological observation showed better bone remodeling effects of the experimental sides than control sides, with connected medullary cavities and continuous bone cortex. And the osteogenetic type was endochondral ossification. Conclusion Local implantation of simvastatin can promote repairing rabbit radial critical bone defect, 100 mg is the best dose of repairing the bone defects.

          Release date:2016-08-31 05:47 Export PDF Favorites Scan
        • Full-Length cDNA Cloning of FXYD6 Gene Related to Cholangiocarcinoma with Bioinformatic Localization of Its Functional Domain

          Objective To obtain the full-length gene and functional domains of FXYD6 gene which is a cholangiocarcinoma related gene. Methods A new strategy with the integration of bioinformatics and molecular biology was used. Bioinformatical methods were used to analyze the full-length sequence, and to predict the functional domains of its protein. And the full-length sequence of FXYD6 was isolated by polymerase chain reaction from fetal hepatic, brain and spleen cDNA libraries, and then cloned in pGEM-T vector for sequence analyzing. Goldkey Sequence Analyzing Software was used to analyze the sequence of candidate domain without signal peptide.Results The full-length sequence of FXYD6 was isolated by Touch-down PCR from fetal hepatic and brain cDNA library, but was not from spleen cDNA library. The open reading frame Finder software was used in the National Center for Biotechnology Information website to find the most probable encoding regions of FXYD6 gene. And the +1 phase was selected as the template sequence, from 67 bp to 354 bp, to predict the functional domains by Goldkey Sequence Analyzing Software. The signal peptide was located from 1 amino acid (aa) to 17 aa, and the main domain was composed from 18 aa to 34 aa. The region between 35 aa and 57 aa was the transmembrane region. The FHYD peptide chain was highly conserved amino acids. Conclusion The study of full-length cDNA cloning of FXYD6 gene and its functional domains provides the basis for understanding the relationship between the structure and function of FXYD6. More work shall be performed on FXYD6 protein and its influence on the mechanism of cholangiocarcinoma.

          Release date:2016-09-08 10:54 Export PDF Favorites Scan
        • IN VITRO DRUG RELEASE BEHAVIOR OF CARRIER MADE OF POROUS GLASS CERAMICS

          OBJECTIVE: To conduct the in vitro test on drug release of rifampin encapsulated in a carrier made of porous phosphate glass ceramics and to analyze main factors which affect the drug release rate. METHODS: A certain quantitative of rifampin was sealed in a hollow cylindrical capsule which consisted of chopped calcium phosphate crystal fiber obtained from glass crystallization. The rifampin concentration was measured in the simulated physiological solution in which the capsule soaked. RESULTS: Rifampin could be released in a constant rate from the porous glass ceramic carrier in a long time. The release rate was dependent on the size of crystal fiber and the wall thickness of the capsule. CONCLUSION: This kind of calcium phosphate glass ceramics can be a candidate of the carrier materials used as long term drug therapy after osteotomy surgery.

          Release date:2016-09-01 10:14 Export PDF Favorites Scan
        • Clinical Analysis of Local Arterial Infusion for the Treatment of Severe Acute Pancreatitis (Report of 30 Cases)

          Objective To investigate a new way for the treatment of severe acute pancreatitis (SAP). Methods The clinical data of 59 cases of SAP were analyzed, and they were divided into two groups: LAI group and control group. In LAI group, 30 cases were treated mainly by local arterial infusion (LAI). In control group, 29 cases were treated by intravenous infusion. Results Compared with control group, the results of LAI group were much better in abdominal pain relief, recovery of intestinal function, reducing the complications, shorter antibiotictime, decreasing the incidence of secondary systemic infection. The mortality of SAP class Ⅱ in LAI group and control group were 35.71% and 66.67% respectively. Conclusion LAI is a new way for the treatment of SAP.

          Release date:2016-08-28 04:47 Export PDF Favorites Scan
        • Effects of 50 Hz electromagnetic field on rat working memory and investigation of neural mechanisms

          With the widespread use of electrical equipment, cognitive functions such as working memory (WM) could be severely affected when people are exposed to 50 Hz electromagnetic fields (EMF) for long term. However, the effects of EMF exposure on WM and its neural mechanism remain unclear. In the present paper, 15 rats were randomly assigned to three groups, and exposed to an EMF environment at 50 Hz and 2 mT for a different duration: 0 days (control group), 24 days (experimental group I), and 48 days (experimental group II). Then, their WM function was assessed by the T-maze task. Besides, their local field potential (LFP) in the media prefrontal cortex (mPFC) was recorded by the in vivo multichannel electrophysiological recording system to study the power spectral density (PSD) of θ and γ oscillations and the phase-amplitude coupling (PAC) intensity of θ-γ oscillations during the T-maze task. The results showed that the PSD of θ and γ oscillations decreased in experimental groups I and II, and the PAC intensity between θ and high-frequency γ (hγ) decreased significantly compared to the control group. The number of days needed to meet the task criterion was more in experimental groups I and II than that of control group. The results indicate that long-term exposure to EMF could impair WM function. The possible reason may be the impaired communication between different rhythmic oscillations caused by a decrease in θ-hγ PAC intensity. This paper demonstrates the negative effects of EMF on WM and reveals the potential neural mechanisms from the changes of PAC intensity, which provides important support for further investigation of the biological effects of EMF and its mechanisms.

          Release date:2023-12-21 03:53 Export PDF Favorites Scan
        7 pages Previous 1 2 3 ... 7 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品