        find Author "SONGChengli" 2 results
        • A New Parameter Measurement System for Electrosurgery Output

          Accurate measurements of voltage and current from electrosurgery are the basis of development of electrosurgery with feedback function. We, therefore, developed a parameter measurement system based on PC, with high voltage and current from electrosurgery being sensed with transformers, amplified, filtered, transformed into single-ended signals, and then into RMS signals. The root mean square (RMS) signals were transformed into digital signals through DAQ card and the data was processed in PC with Labview. The process included sampling, displaying and storage. The experiment results indicated that the measurement system could measure the output parameters from electrosurgery steadily and correctly so that the development of the system has been successful. It can be the basis of development of embedded parameters measurement system and can provide accurate feedback information for intellectual electrosurgery.

          Release date: Export PDF Favorites Scan
        • Design and In Vitro Experimental Study of an Endoscopic Multipleclip Applier

          Considering the problems such as reposition limited, easily detached and singly fired of the existing clip products, we developed an endoscopic multiple-clip applier which can apply 4 clips fired successively at a time. The instrument also equipped with an independent grasper which can be used to clamp target tissues. In order to explore its feasibility and effectiveness of endoluminal closure of gastric perforation, 22 pig stomachs were making a 1 cm full-thickness incision from outside and closed by multiple-clip applier (n=12) in vitro. Outcome was measured by bursting pressure and compared with negative control (n=5) and hand suture (n=5). We set a threshold pressure value (10 mm Hg) for a secure closure. Except 2 cases of invalid data, the mean bursting pressures of negative control, multiple-clip applier, hand suture were (1.5±0.3) mm Hg, (46.0±7.1) mm Hg, and (72.5±7.7) mm Hg, respectively. The results showed that bursting pressure of multiple-clip applier was significantly higher than that of negative control (P<0.05) and threshold value. Multiple-clip applier can be served as an effective and safe device to perform the endoluminal closure of gastric perforation.

          Release date: Export PDF Favorites Scan