1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Author
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Author "TAN Tong" 12 results
        • Clinical outcomes of one-stage transcatheter aortic and mitral valve replacement in patients with combined valvular disease

          ObjectiveTo summarize and analyze the clinical outcomes of one-stage transcatheter aortic valve replacement (TAVR) combined with transcatheter mitral valve replacement (TMVR) in patients with concomitant severe aortic and mitral valve disease. Methods We retrospectively collected the clinical data of patients who underwent one-stage TAVR and TMVR at Beijing Anzhen Hospital between January 2019 and May 2025. Baseline characteristics, procedural details, and perioperative echocardiographic results were recorded. Survivors were followed regularly, and the incidence of major adverse cardiovascular and cerebrovascular events was assessed. ResultsA total of 12 high-risk patients with concomitant severe aortic and mitral valve disease were included, comprising 7 males with a mean age of (73.3±5.4) years. Aortic valve pathology included mixed lesions (n=1), aortic regurgitation (n=8), and aortic stenosis (n=3). Among them, 7 patients had previously undergone surgical bioprosthetic aortic valve replacement. Mitral valve pathology consisted of bioprosthetic valve degeneration leading to isolated regurgitation (n=8) or mixed lesions (n=4); 11 patients had a prior surgical bioprosthetic mitral valve replacement. All patients successfully underwent one-stage TAVR combined with TMVR, with 10 procedures performed via the transapical approach, 1 via the transfemoral approach, and 1 via a combined transfemoral-transapical approach. Valve deployment was successful in all cases, with an overall device success rate of 91.7%. The median intensive care unit stay was 1.5 (IQR 1.3, 3.4) d. Early postoperative complications included 2 perioperative deaths and 2 cases of gastrointestinal bleeding, with no other major cardiovascular events observed. During follow-up, there were no deaths, permanent pacemaker implantations, and no occurrences of moderate-to-severe valve stenosis, paravalvular leak, or left ventricular outflow tract obstruction. Conclusion This study demonstrates that one-stage TAVR combined with TMVR is safe and effective in selected high-risk patients with concomitant severe aortic and mitral valve disease, and represents a feasible therapeutic option.

          Release date: Export PDF Favorites Scan
        • Research progress of transcatheter aortic valve replacement in patients with coexisting moderate to severe mitral regurgitation

          After nearly two decades of application and development, the clinical efficacy of transcatheter aortic valve replacement (TAVR) has been continuously improved and demonstrated. Due to the expansion of indications of TAVR, the frequency of encountering patients with mixed valvular diseases increases greatly, particularly the moderate to severe mitral regurgitation combined with aortic stenosis. Multiple registry studies suggest that the incidence of significant mitral regurgitation is approximately 13% to 74% in patients who undergo TAVR. Some studies have reported that moderate to severe MR is associated with higher mortality, while simultaneous aortic and mitral valve surgery is associated with significantly higher surgical risk. Therefore, the optimal treatment strategy for this special patient group remains uncertain. With the further development of transcatheter therapy, staged surgery may be a feasible solution. However, there is currently a lack of evidence-based support such as randomized clinical trials. This review aims to report and evaluate relevant existing research data to help clinicians make optimal treatment decisions for this specific patient populations.

          Release date:2022-08-25 08:52 Export PDF Favorites Scan
        • Totally endoscopic transmitral septal myectomy for the treatment of recurrent left ventricular outflow tract obstruction after alcohol septal ablation

          ObjectiveTo investigate the surgical strategies and clinical efficacy of transmitral septal myectomy in the treatment of recurrent left ventricular outflow tract obstruction (LVOTO) after alcohol septal ablation. MethodsThe clinical data of patients with recurrent LVOTO after alcohol septal ablation from July 2020 to July 2021 in the Department of Cardiac Surgery, Guangdong Provincial People's Hospital were retrospectively analyzed. Patients were preoperatively evaluated by echocardiography, cardiac magnetic resonance imaging, cardiac computed tomography, 3D modeling and printing technology. A personalized surgical strategy was preoperatively developed according to multimodality imaging assessment, while visual exploration was performed on the digital model and simulated surgical resection was performed on the printed model. Results Two female patients were enrolled, aged 62 years and 64 years, respectively. Totally endoscopic transmitral extended myectomy was successfully performed on both patients with aortic cross-clamping time of 96 min and 85 min, respectively. LVOTO was relieved immediately (subaortic peak pressure gradient decreased from 100 mm Hg to 4 mm Hg and from 84 mm Hg to 6 mm Hg, respectively) and the mitral regurgitation significantly improved after the procedure. No patient had complete atrioventricular block or required permanent pacemaker implantation. The patients were discharged uneventfully without postoperative complications. ConclusionPersonalized totally endoscopic transmitral extended myectomy combined with multimodality imaging assessment and 3D modeling and printing has an acceptable clinical effect in patients with recurrent LVOTO after alcohol septal ablation. The procedure can precisely resect the hypertrophic septal myocardium while avoiding serious complications such as septal perforation or complete atrioventricular block.

          Release date:2023-07-25 03:57 Export PDF Favorites Scan
        • Transapical approach under 3D printing guidance for myectomy in apical hypertrophic cardiomyopathy: A case report

          We reported a 26-year-old male who was diagnosed with apical hypertrophic cardiomyopathy with left ventricular aneurysm. The location of the hypertrophic myocardium and the extent of resection were accurately assessed preoperatively using 3D modeling and printing technology. Myectomy was performed via transapical approach, and the intraoperative exploration was consistent with the description of the preoperative 3D modeling. The patient underwent the surgery successfully without any complications during the hospitalization, and the cardiopulmonary bypass time was 117 min, the aortic cross-clamping time was 57 min, and the hospital stay time was 7 d. The postoperative echocardiography demonstrated left ventricular cavity flow patency. This case provides a reference for the management of patients with apical hypertrophic cardiomyopathy.

          Release date:2023-08-31 05:57 Export PDF Favorites Scan
        • Clinical effect of transcatheter aortic valve replacement on severe aortic regurgitation combined with severe mitral regurgitation: A single-center retrospective study

          ObjectiveTo determine the clinical efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic regurgitation (AR) combined with severe mitral regurgitation (MR). MethodsThe clinical data of 13 patients who underwent TAVR due to severe AR combined with severe MR from March 2018 to September 2021 in our hospital were retrospectively analyzed, including 10 males and 3 females with a mean age of 72.54±2.35 years. The echocardiographic findings of all patients were compared preoperatively and postoperatively. ResultsSurgeries were performed successfully in all patients without intraoperative death or conversion to sternotomy. The operation time was 118.15±11.42 min, intraoperative blood loss was 100.00 (75.00, 250.00) mL, and the length of hospital stay after surgery was 9.00 (4.50, 11.00) d. The mean follow-up duration was 10.00 (6.50, 38.50) months, during which there were 2 patients with mild to moderate AR, 6 with mild AR, and 5 with no AR; meanwhile, severe MR decreased significantly (P=0.001) even without active intervention, including 4 mild to moderate MR and 9 mild MR patients. Compared to preoperative indexes, the left atrial diameter [46.00 (41.00, 52.50) mm vs. 35.00 (34.00, 41.00) mm, P<0.001], left ventricular end-systolic diameter [45.00 (36.00, 56.00) mm vs. 35.00 (28.00, 39.00) mm, P=0.002] and left ventricular end-diastolic diameter (62.62±2.40 mm vs. 51.08±2.49 mm, P<0.001) showed a decreasing trend during the follow-up. ConclusionIn selected patients with severe AR combined with severe MR, TAVR alone improves AR and combined MR at the same time.

          Release date:2022-08-25 08:52 Export PDF Favorites Scan
        • Preliminary clinical outcomes of the domestic Renatus? balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

          Objective To evaluate the early clinical outcomes of the Renatus? balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus? balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus? balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

          Release date:2023-03-01 04:15 Export PDF Favorites Scan
        • Transapical transcatheter valve-in-valve implantation treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement

          ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.

          Release date:2021-07-28 10:22 Export PDF Favorites Scan
        • Clinical efficacy and survival analysis of totally thoracoscopic redo mitral valve replacement

          Objective To analyze the clinical efficacy and survival outcome of totally thoracoscopic redo mitral valve replacement and evaluate its efficiency and safety. Methods The clinical data of patients with totally thoracoscopic redo mitral valve replacement in Guangdong Provincial People’s Hospital between 2013 and 2019 were retrospectively analyzed. Survival analysis was performed using the Kaplan-Meier method. Univariate and multivariate Cox regression analyses were used to determine the risk factors for postoperative death. Results There were 48 patients including 29 females and 19 males with a median age of 53 (44, 66) years. All the procedures were performed successfully with no conversion to median sternotomy. A total of 15, 10 and 23 patients received surgeries under non-beating heart, beating heart and ventricular fibrillation, respectively. The in-hospital mortality rate was 6.25% (3/48), and the incidence of early postoperative complications was 18.75% (9/48). Thirty-five (72.92%) patients had their tracheal intubation removed within 24 hours after the operation. The 1- and 6-year survival rates were 89.50% (95%CI 81.30%-98.70%) and 82.90% (95%CI 71.50%-96.20%), respectively. Age>65 years was an independent risk factor for postoperative death (P=0.04). Conclusion Totally thoracoscopic redo mitral valve replacement is safe and reliable, with advantages of rapid recovery, reducing blood transfusion rate, reducing postoperative complications and acceptable long-term survival rate. It is worthy of being widely popularized in the clinic.

          Release date:2023-05-09 03:11 Export PDF Favorites Scan
        • Application of bicuspid pulmonary valve sewn by 0.1 mm expanded polytetrafluoroethylene in right ventricle outflow tract reconstruction

          Objective To introduce a modified technique of right ventricular outflow tract (RVOT) reconstruction using a handmade bicuspid pulmonary valve crafted from expanded polytetrafluoroethylene (ePTFE) and to summarize the early single-center experience. Methods Patients with complex congenital heart diseases (CHD) who underwent RVOT reconstruction with a handmade ePTFE bicuspid pulmonary valve due to pulmonary regurgitation at Guangdong Provincial People’s Hospital from April 2021 to February 2022 were selected. Postoperative artificial valve function and right heart function indicators were evaluated. Results A total of 17 patients were included, comprising 10 males and 7 females, with a mean age of (18.18±12.14) years and a mean body weight of (40.94±19.45) kg. Sixteen patients underwent reconstruction with a handmade valved conduit, with conduit sizes ranging from 18 to 24 mm. No patients required mechanical circulatory support, and no in-hospital deaths occurred. During a mean follow-up period of 12.89 months, only one patient developed valve dysfunction, and no related complications or adverse events were observed. The degree of pulmonary regurgitation was significantly improved post-RVOT reconstruction and during follow-up compared to preoperative levels (P<0.001). Postoperative right atrial diameter, right ventricular diameter, and tricuspid regurgitation area were all significantly reduced compared to preoperative values (P<0.05). Conclusion The use of a 0.1 mm ePTFE handmade bicuspid pulmonary valve for RVOT reconstruction in complex CHD is a feasible, effective, and safe technique.

          Release date:2025-07-23 03:13 Export PDF Favorites Scan
        • Pulsed field surgical ablation treatment for atrial fibrillation: The first case report

          Atrial fibrillation is a common clinical arrhythmia with a high incidence. The main clinical treatment methods for atrial fibrillation at present include radiofrequency catheter ablation and cryoablation. In recent years, pulsed field ablation, a new energy source with tissue specificity, is gradually being used in clinical practice. This article presents the world's first case of atrial fibrillation treated with pulsed field surgical ablation, in which the patient underwent surgical intervention of the valves and coronary arteries at the same time and recovered to sinus rhythm intraoperatively. 24 hour-Holter electrocardiogram after 1 month and 3 months showed no atrial fibrillation. The patient’s symptoms, cardiac function, and quality of life improved significantly.

          Release date:2023-12-10 04:52 Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品