1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "TEE" 5 results
        • Transcatheter edge-to-edge repair: Operating theories, basic principles, and predictors of prognosis

          Mitral regurgitation is one of the most common heart valve diseases. Transcatheter edge-to-edge repair (TEER) is currently the most developed and commonly used interventional technique for mitral regurgitation and is recommended by the latest European and American guidelines for patients who are at high surgical risk. TEER device usually consists of a clamping device and a delivery system. The trajectory of the clamping device is called the trajectory, and the trajectory can be well established with the five dimensions movement of the delivery system: left-right oscillation, anterior-posterior oscillation, overall parallel movement, the clamping device's own clockwise rotation, and vertical up-and-down movement. The delivery system's anteroposterior and lateral oscillations are concentrated on the virtual puncture site. Furthermore, the location of the septal puncture site has a significant impact on the establishemnt of the trajectory. The evulation of three variables and adherence to the "4M principles" are necessary for the successful TEER. The three variables are: the position of the clip in the center of the regurgitation,the arm orientation of the clip perpendicular to the boundary of anterior and posterior leaflets, as well as the appropriate length of clamping. The "4M principles" include favorable valve morphology, residual mitral regurgitation below grade 2+, mean transvalvular pressure≤5 mm Hg, and an appropriate amount of leaflets clamping. Patients' baseline situation, the degree of mitral regurgitation and ventricular remodeling, as well as the valve morphology and the outcome of the procedure, are the factors determining the prognosis of patients after TEER.

          Release date:2022-08-25 08:52 Export PDF Favorites Scan
        • The Application of Transesophageal Echoeardiography for Atrial Septal Defect Blockade Operation

          【摘要】 目的 評價經食管超聲心動圖(TEE) 監測房間隔缺損封堵術的臨床價值。 方法 手術前應用經胸超聲心動圖(TTE)及TEE篩選符合條件的100例單純房間隔缺損(ASD)患者行封堵術;手術中TEE監測整個封堵過程和引導封堵傘的放置;手術后評價封堵效果、殘余分流或并發癥等。 結果 100例患者均應用TTE和TEE確診,導引和監測成功閉合房間隔缺損。技術成功96例,成功率96%;4例失敗,失敗率4%。手術后復查無1例殘余分流,3例胸腔積液。經胸超聲心動圖與TEE診斷結果完全一致率40%,TEE診斷對手術前TTE診斷做出補充或修正診斷的有60例(60%)。結論 TEE對選擇適合行封堵術者、選擇封堵器大小、指導封堵器的釋放、以及療效評價均具有重要的作用。【Abstract】 Objective To evaluation the clinical role of transesophageal echocardiography (TEE) for atrial septal defect (ASD) blockade operation. Method The 100 patients with ASD were selected on transthoracic echocardiography (TTE) and TEE. During operation, TEE was applied to monitor the procedure of occlusion, to guide the occluder cites, to evaluate the effects and to make sure if there were peripheral residual shunts around the occlusion and other complications. Results All of the patients were exactly diagnosed by TTE and TEE,guiding and evaluating the successful closed ASD. The successful rate of occlusion was 96%,the failure rate was 4%. The review after surgery showed that, there were no residual review, pleural effusion in three patients. The concordance rate of TTE and TEE diagnosis result is 40%. TEE diagnosis amend the preoperative TTE diagnosis in 60 patients (60%). Conclusions TEE plays an important role in select inpatients,determining the size of the occluder,correctly before occlusion operation, guiding the placement of the occluder in operation and evaluating the effect after operation.

          Release date:2016-09-08 09:45 Export PDF Favorites Scan
        • 經食道超聲心動圖檢查患者的護理干預

          【摘要】 目的 總結經食道超聲心動圖(TEE)檢查患者的護理干預及方法。 方法 對2004年1月-2009年12月行TEE檢查的1 988例患者進行回顧分析。 結果 術前充分準備,術中配合及良好的術后護理,無醫療事故發生,取得了良好效果。  結論 對行TEE檢查的患者在不同的檢查階段進行不同的護理干預,有助于提高患者對檢查的正確認識及減少并發癥的出現。

          Release date:2016-09-08 09:24 Export PDF Favorites Scan
        • Adductor canal block versus femoral nerve block for total knee arthroplasty: a meta-analysis of randomized controlled trials

          Femoral nerve blocks (FNB) can provide effective pain relief but result in quadriceps weakness with increased risk of falls following total knee arthroplasty (TKA). Adductor canal block (ACB) is a relatively new alternative providing pure sensory blockade with minimal effect on quadriceps strength. The meta-analysis was designed to evaluate whether ACB exhibited better outcomes with respect to quadriceps strength, pain control, ambulation ability, and complications. PubMed, Embase, Web of Science, Wan Fang, China National Knowledge Internet (CNKI) and the Cochrane Database were searched for RCTs comparing ACB with FNB after TKAs. Of 309 citations identified by our search strategy, 12 RCTs met the inclusion criteria. Compared to FNB, quadriceps maximum voluntary isometric contraction (MVIC) was significantly higher for ACB, which was consistent with the results regarding quadriceps strength assessed with manual muscle strength scale. Moreover, ACB had significantly higher risk of falling versus FNB. At any follow-up time, ACB was not inferior to FNB regarding pain control or opioid consumption, and showed better range of motion in comparison with FNB. ACB is superior to the FNB regarding sparing of quadriceps strength and faster knee function recovery. It provides pain relief and opioid consumption comparable to FNB and is associated with decreased risk of falls.

          Release date: Export PDF Favorites Scan
        • Transcatheter edge-to-edge repair (TEER): Past, current and future perspectives

          Transcatheter edge-to-edge repair (TEER) originated from surgical edge-to-edge repair. MitraClip is the first mature TEER device, and the TEER based on MitraClip is far ahead of many transcatheter mitral valve repair (TMVr) technologies in terms of safety, effectiveness and popularity, so it is named separately in the latest guidelines. The TEER has the following advantages: consistent with basic medical principles, few implants, precise target, less invasive and repeatable. However, there are also some shortcomings, such as the relatively complex design of transfemoral device, target single and relatively narrow indications. At present, the main clinical data of TEER are mainly from the clinical practice of MitraClip. Based on the three-year outcomes of COAPT study, both 2020 ACC/AHA guideline and 2020 ACC expert consensus decision pathway on the management of mitral regurgitation recommend in patients with chronic heart failure with left ventricular dysfunction and severe mitral regurgitation in nonresponders to medicine treatment. Edward's PASCAL, another TEER device, has two models. Among the domestic TEER devices, the ValveClamp of Hanyu medical technology has many distinct advantages, such as simple operation, large clamping area, high clamping efficiency and no need of X-ray. DragonFly, another domestic TEER device, has also completed its feasibility study. There are five trends of TEER in the future: further expansion of indications, combination with other interventional techniques, repeatable operations, transcatheter mitral valve replacement after TEER, and continuous improvement and innovation of equipment.

          Release date:2021-12-27 11:31 Export PDF Favorites Scan
        1 pages Previous 1 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品