Objective To study the efficiency of percutaneous acetic acid injection (PAI) or percutaneous ethanol injection (PEI) in the treatment of primary hepatic carcinoma (PHC). Methods Seventeen and 24 patients with PHC were treated, respectively by PAI or by PEI in our hospital. According to hepatic function test, soluble intereukin-2 receptor (sIL-2R), AFP, biopsy and size of tumor, the evaluation was made.Results Effective rate was 88.2% in PAI group and 87.5% in PEI group, respectively. There was no obvious influence to sIL-2R in serum in the two groups (P>0.05). Obvious differences in impairment of hepatic functions between PAI and PEI groups were found (P<0.01), it also showed that smaller amounts of acetic acid and less puncture frequency were required for the treatment than that of ethanol. Conclusion PAI is superior to PEI in the treatment of those patients who are complicated with cirrhosis or other vital disease.
ObjectiveTo explore the significance of ultrasound combined with magnetic resonance imaging (MRI) in the diagnosis of pernicious placenta previa (PPP).MethodsA total of 101 patients with suspected PPP admitted to Chengdu Women’s and Children’s Central Hospital from January 2016 to February 2019 were retrospectively analyzed. The surgical results were used as the gold standard, and the diagnostic value of ultrasound, MRI, ultrasound combined with MRI was compared.ResultsSurgery results showed that among the 101 patients with suspected PPP, 79 patients had positive PPP diagnosis and 22 patients had negative PPP diagnosis. There was no significant difference in the diagnostic sensitivity, negative predictive value, or diagnostic coincidence rate of PPP among ultrasound, MRI, and ultrasound combined with MRI (P>0.05). The diagnostic specificity of the series combination of ultrasound and MRI (86.36%) was higher than that of ultrasound (59.10%), MRI (59.10%), and the parallel combination of ultrasound and MRI (31.32%), and the differences were statistically significant (P<0.05). The diagnostic coincidence rates of abnormal placental attachment of MRI (96.20%) and the parallel combination of ultrasound and MRI (96.20%) were higher than that of ultrasound (87.34%) and the series combination of ultrasound and MRI (87.34%) (P<0.05).ConclusionsUltrasound combined with MRI has a high diagnostic value for PPP. If necessary, ultrasound combined with MRI can be considered to improve the diagnostic efficiency.
Objective To evaluate the therapeutic effects of percutaneous microwave ablation (MWA) for metastatic liver cancer. Methods Ultrasound-guided percutaneous MWA technique was used to treat 27 cases of hepatic metastases with 69 nodules 〔0.9-13.2 (3.0±2.0) cm in diameter〕. Local therapeutic effect, local and distant recurrence rate and survival rate were evaluated respectively. Results The complete ablation (CA) rate which was used to evaluate the local therapeutic effects was 92.8% (64/69), with 100% (34/34), 92.3%(24/26) and 66.7% (6/9) in a diameter of nodules lt;3.0 cm, 3.0-5.0 cm and ≥5.0 cm respectively. The CA rate was lower in the group of a diameter of nodules ≥5.0 cm as compared with other two groups (Plt;0.05). The local recurrence rate was 9.4% (6/64), with 2.9% (1/34), 16.7% (4/24) and 16.7% (1/6) in a diameter of nodules lt;3.0 cm, 3.0-5.0 cm and ≥5.0 cm respectively. The intrahepatic distant recurrence rate was 44.4% (12/27). The follow-up time after MWA was 3-34 (17.0±8.7) months. During the follow-up period, 6 months, 1 and 2-year cumulative survival rate was 88.9%, 63.0% and 34.4% respectively, with a mean survival time of 17.8 months, and with a median survival time of 19.0 months.Conclusion Percutaneous MWA treatment offers satisfactory local tumoricidal efficacy to metastatic liver cancer and the patients with recurrence and new metastases can be therapy repeatedly to improve long-term survival.
Quantitative analysis of ultrasound molecular imaging is of great significance for clinical diagnosis and research. Based on Visual Studio development platform and C# language, this paper designs a set of ultrasound molecular imaging region of interest quantitative analysis software, which can complete the ultrasound image scaling processing, rectangular and arbitrary shape of the region of interest capture, mark saving and loading, gray value quantitative analysis and so on. In this paper, the function of the software is described in detail and the software is tested and verified. It is proved that the software can quantitatively analyze the conventional ultrasound images and ultrasound contrast images, which can provide a basis for the relevant research on the quantitative analysis of the gray value of ultrasound molecular imaging.
Objective To systematically review the clinical value of color Doppler ultrasonic for diagnosing female breast cancer. Methods We electronicaaly searched the databases including The Cochrane Library (Issue 2, 2013), EMbase, PubMed, CNKI, WanFang Data, MedaLink ,VIP and CBM for diagnostic tests on breast cancer diagnosed with color Doppler ultrasonic vs. with pathological biopsy (golden criteria) from 1982 to the March, 2013. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed the methodological quality of the included studies according to QUADAS items. The Meta-DiSc software (version 1.4) was used to conduct pooling on sensitivity, specificity, positive likelihood radio, and negative likelihood radio. Heterogeneity test was performed and the summary receiver operating characteristic curve (SROC) was drawn for area under the curve (AUC). Results A total of 25 studies involving 3 274 patients were included. The results of meta-analysis showed that, SPE, SEN, +LR, ?LR and DOR were (0.76, 95%CI 0.74 to 0.78), (0.80, 95%CI 0.78 to 0.82), (3.58, 95%CI 2.63 to 4.87), (0.28, 95%CI 0.22 to 0.35) and (13.76, 95%CI 8.47 to 22.36), respectively. The AUC of SROC curve was 0.865 7. Conclusion Current evidence shows that color Doppler ultrasonic has high sensitivity (80%) and high specificity (76%) in the diagnosis of high-frequency Ultrasound. The positive rate in the breast cancer group is 13.76 times as high as that in non-breast cancer, which indicates color Doppler ultrasonic has good diagnostic value for breast cancer.
Objective To assessment of the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter[ (237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD (18.5±5.7 min vs. 30.3±4.5 min, P<0.001) and substantially increased the detection rate within the right ventricle (100% vs. 30%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibited superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
An elderly female patient, with systemic multiple organ dysfunction, suffered from severe aortic valve stenosis, was to undergo transcatheter aortic valve replacement (TAVR). She was intolerance of the computed tomography examination before surgery. Bedside echocardiography was employed to evaluate the patient’s aortic valve stenosis, valve anatomy and type, the condition of aortic root, the distance from coronary to aortic root, and lower-extremity vascular access. Finally, the emergent TAVR was successfully performed under general anesthesia, and the aortic valve trans-prosthetic gradient met a remarkable decrease after surgery.
Objective To review the research progress of ultrasound in the diagnosis and treatment of shoulder diseases, in order to provide a theoretical basis for the further development of ultrasound in shoulder surgery. Methods The recent literature on the application of ultrasound in the shoulder joint was extensively reviewed. The application of ultrasound in the diagnosis and treatment of shoulder joint diseases, and the advantages and disadvantages of ultrasound were analysed, and the development trend of ultrasound technology in the shoulder joint area was prospected. Results At present, the diagnosis of shoulder joint diseases mainly relies on MRI, however, with the development of ultrasound technology, ultrasound with the characteristics of convenient, reliable, and real-time dynamic evaluation is more and more recognized in the diagnosis process of shoulder joint diseases, combined with three-dimensional ultrasound, ultrasound intervention, and elastography can improve the accuracy, sensitivity, and specificity of the diagnosis, and is suitable for the diagnosis and treatment of various shoulder joint diseases, which is expected to carry out early prevention of shoulder joint diseases in the future and achieve more refined and minimally invasive treatment. ConclusionUltrasound technology has wide application prospect in shoulder joint diseases, but it is still in the developing stage, and the subjective dependence needs to be solved further.
ObjectiveTo investigate the value of ultrasound knife in modified radical mastectomy for remaining pectoral nerve and intercostobrachial nerve.
MethodsOne hundred and sixty patients with breast cancer were divided into ultrasound knife group and electroscalpe group and then performed modified radical mastectomy with pectoral nerve and intercostobrachial nerve remainning. the pectoralis major thickness and paresthesia of skin of inner upper arm and axillary fossa were detected on the different time after operation.
Results①The age, body mass index, and mean opera-tion time had no significant differences between these two groups (P > 0.05).②On 6 months after operation, the thickness of bilateral pectoralis major was not significantly different in the ultrasound knife group (P > 0.05), which of injuried pectoralis major was significantly thinner than that of uninjuried pectoralis major in the electroscalpe group (P < 0.05).③The rates of paresthesia of skin on postoperative 3 months and 6 months in the ultrasound knife group were signifi-cantly lower than those in the electroscalpe group (P < 0.05).
ConclusionCompared with monopolar electro diathermy, the use of ultrasonic harmonic scalpel in modified radical mastectomy could better protect pectoral nerve and intercosto-brachial nerve, and thus decrease nerve parafunctional rate.
ObjectiveTo evaluate the viability, short-term clinical efficacy, and safety of ultrasound-guided radioactive seed 125I permanent implantation in tissue in patients with advanced colorectal cancer.
MethodsA total of 9 patients were recruited in this study. All of the patients came from China-Japan Union Hospital of Jilin University from October 2012 to October 2014, which had been selected after strict screening. Five cases of male patients, 4 cases of female patients; the age was between 46-78 years old, the median age was 54 years old. There were 5 cases of patients with pain. There were 14 lesions in total, 1 lesion was local tumor recurrence, 2 lesions were pelvic metastasis, 8 lesions were liver metastases, and 3 lesions were abdominal lymph node metastasis. CEA increased in 6 cases before implantation. All patients were confirmed metastasis by CT, MRI examination or pathology. The 125I radioactive seed implantation was guided by real-time ultrasound. CT scanning was taken in two months after treatment. The degree of pain relief, tumor local control, and the occurrence of complications were observed.
ResultsIn 2 months after implantation of 125I radioactive particles, the CT scanning results showed that 2 cases obtained complete response (CR), 5 cases obtained partial response (PR), 1 case got stable disease (SD), and 1 case got progress disease (PD). Total effective was 7/9, and disease control was 8/9. Five cases with pain symptoms were relieved after treatment. One walk metal particle in the abdominal cavity was found by abdominal CT scanning in 1 case. There were no serious complications intraoperative and postoperative.
ConclusionsUltrasound guided radioactive seeds 125I implantation in the treatment of advanced colorectal cancer can significantly relieve the clinical symptoms, improve the quality of life, and can effectively control the metastasis. It is safe and feasible, and the postoperative hospitalization time is short, it has the avantages of safety, effectiveness, and low incidence of complications.