ObjectiveTo evaluate the predictive value of diaphragmatic rapid shallow breathing index (D-RSBI) for weaning outcome prediction.MethodsThis was a prospective observation study. Respiratory rate (RR) and tidal volume (Vt) were recorded at the end of spontaneous breathing trial, and both M-Mode and B-Mode ultrasonography were used to assess the right diaphragmatic displacement (DD). In parallel, outcome of the weaning attempt, length of mechanical ventilation, length of stay in intensive care unit (ICU) and mortality of ICU were recorded. According to the weaning outcome, the patients were grouped into the successful group and the failed group. The receiver operator characteristic (ROC) curve was used to assess the value of rapid shallow breathing index (RSBI, RR/Vt) and D-RSBI (RR/DD) in predicting weaning failure for ICU patients with mechanical ventilation.ResultsA total of 110 patients recruited in this study. Of them, 73 (66.4%) patients were successfully liberated from mechanical ventilation, and 37 patients failed (33.6%) weaning procedure. The RSBI and D-RSBI of the patients in the failed group were higher than those in the success weaning group (P<0.01). The area under the ROC curves of RSBI and D-RSBI for predicting weaning failure was 0.78 (95% confidence interval 0.69 - 0.87), 0.91 (95% confidence interval 0.85 - 0.97), respectively, a cutoff of RSBI>69 breaths/(L·min) yielded sensitivity of 55% and specificity of 89%, and a cutoff of D-RSBI>1.5 breaths/(min·mm) yielded sensitivity of 87% and specificity of 80%.ConclusionD-RSBI is more accurate than traditional RSBI in predicting the weaning outcome.
ObjectiveTo investigate the predictive value of diaphragm rapid shallow breathing index (D-RBSI) in weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease (COPD).MethodsSeventy-six patients with COPD who were undergoing mechanical ventilation were enrolled in department of critical care medicine of our hospital from March 2016 to March 2017. The patient underwent spontaneous breathing test (SBT) using CPAP mode after weaning screening. When the SBT had started 10 min or the SBT failed, the patients' respiratory rate (RR) and tidal volume were recorded, and the diaphragmatic displacement (DD) of patients was measured by bedside ultrasound. The ratio of RR to DD (RR/DD) was calculated as D-RBSI, and the predictive value of D-RBSI on weaning results in mechanically ventilated patients with COPD was analyzed by receiver operating characteristic (ROC) curve.ResultsTwenty-eight patients failed weaning procedure. There were no significant differences in age and acute physiology and chronic health evaluation II scores between the successful group and the failed group. The DD of the patients in the successful group was greater than that of the failed group [(22±6) mm vs. (13±5) mm, P<0.001]. RBSI and D-RBSI of the successful group were lower than those of the failure group [RBSI: (40±14) breaths/(min·L)vs. (52±20) breaths/(min·L), P=0.003; D-RBSI: (0.95±0.51) breaths/(min·mm) vs. (1.79±0.83) breaths/(min·mm), P<0.001)]. There was a good correlation between the RBSI and D-RBSI in the two groups (R2=0.778, P<0.001). The area under the ROC curve predicted the weaning result by D-RBSI was higher than RBSI (0.85vs. 0.75, P<0 001="" the="" cutoff="" value="" of="" d-rbsi="">1.13 breaths/(min·mm) to predict weaning failure had a sensitivity of 0.82, and a specificity of 0.81.ConclusionThe rapid shallow breathing index of diaphragm can be effectively used to predict the weaning result of COPD patients during mechanical ventilation.
ObjectiveTo investigate the clinical value of peripheral blood vitamin D level in predicting the outcome of weaning from mechanical ventilation in critically ill patients.MethodsA total of 130 critically ill patients who undergoing mechanical ventilation for more than 48 hours in our hospital were recruited from June 2014 to June 2017. Serum 25(OH)D3 was detected on admission and before spontaneous breathing test (SBT) meanwhile general clinical data and laboratory examination indexes were recorded. The cases were divided into a successful weaning group and a failure weaning group according to the outcome of weaning from mechanical ventilation. Logistic regression equation was used to analyze the relationship between vitamin D level and failure weaning, and a receiver operating characteristic (ROC) curve was used to analyze the predictive value for failure weaning.ResultsThere were 46 patients with failure weaning among 130 patients (35.38%). Compared with the successful weaning group, the failure weaning group had significantly higher Acute Physiology and Chronic Health EvaluationⅡ score, longer duration in intensive care unit, higher respiratory rate, higher rapid shallow breathing index, higher C-reactive protein, higher N-terminal prohormone of brain natriuretic peptide, higher serum creatinine, and significantly lower albumin (all P<0.05). 25(OH)D3 level classifications on admission and before SBT in the failure weaning group were worse than those in the successful weaning group (P<0.05). 25(OH)D3 levels of the failure weaning group were lower than those of the successful weaning group [on admission: (18.16±4.33) ng/ml vs. (21.60±5.25) ng/ml, P<0.05; before SBT: (13.50±3.52) ng/mlvs. (18.61±4.30) ng/ml, P<0.05]. Multivariate logistic regression analysis showed that 25(OH)D3 levels on admission and before SBT were independent risk factors for failure weaning (OR values were 2.257 and 2.613, respectively, both P<0.05). ROC curve analysis showed that areas under ROC curve were 0.772 and 0.836, respectively, with sensitivities of 80.3% and 85.2%, specificities of 69.0% and 71.0%, respectively.Conclusions25(OH)D3 deficiency or insufficiency is common in critically ill patients. The lower the level of vitamin D, the higher the risk of failure weaning. So it may be an independent predictor of failure weaning.
Objective To assess the risk factors associated with extubation failure in patients who had successfully passed a spontaneous breathing trial.Methods Patients receiving invasive mechanical ventilation for over 48 h were enrolled in the study,they were admitted into Emergency ICU of Zhongshan Hospital during May 2006 and Oct.2007.A spontaneous breathing trial was conducted by a pressure support of 7 cm H2O for 30 min.Clinical data were prospectively recorded for the patient receiving full ventilatory support before and after the spontaneous breathing trial.Regarding the extubation outcome,patients were divived into extubation success group and extubation failure group.Results A total of 58 patients with a mean(±SD) age of 69.4±12.7 years passed spontaneous breathing trial and were extubated.Extubation failure occurred in 11 patients(19%).The univariate analysis indicated the following associations with extubation failure:elderly patients(78.1±7.9 years vs 67.4±15.1years,Plt;0.05),higher rapid shallow breathing index(RSBI) value(83±12 breaths·min-1·L-1 vs 68±19 breaths·min-1·L-1,Plt;0.05)and excessive respiratory tract secretions(54.5% vs 21.3%,Plt;0.05).Conclusion Among routinely measured clinical variables,elderly patients,higher RSBI value and amount of respiratory tract secretions were the valuable index for predicting extubation failure despite a successful spontaneous breathing trial.
Weaning difficulty is common in critically ill patients. Prolonged mechanical ventilation and weaning failure adversely affect the clinical outcome. How to better promote and achieve the early extubation is a very important subject. As a multi-dimensional monitoring method of important structure, function and morphology, critical care ultrasound which is helpful to improve our understanding and grasp of the core links in the respiratory circuit can comprehensively evaluate the state and reserve capacity of some important organs, such as the heart, lungs and diaphragm. It has great value in assessment of weaning and guided treatment. This paper will review the application of severe ultrasound in weaning.
Objective To investigate whether the respiratory support weaning based on adaptive support ventilation ( ASV) could reduce the duration of mechanical ventilation in patients after fast-track coronary artery bypass grafting ( CABG) . Methods After CABG during the same fast-track general anesthesia, 46 patients were randomly assigned to an ASV group or a synchronized intermittent mandatory ventilation ( SIMV) group as control. The duration of mechanical ventilation, hemodynamic parameters, and airway pressures were recorded. Meanwhile, the variables and the number of the arterial blood gas were recorded. Results The duration of mechanical ventilation was shorter in the ASV group than that in the control group [ 196( 152-286) ] min vs. 253( 196-498) min, P lt;0. 05] . The duration of ICUstay was shorterin the ASV group than that in the control group [ ( 14. 5 ±0. 7) h vs. ( 16. 8 ±0. 4 ) h, P lt;0. 01] . Fewer arterial blood analyses were performed in the ASV group than those in the control group [ 5 ( 4-7) vs.7( 6-9) , P lt; 0. 05] . Conclusions A ventilation weaning protocol based on ASV is practicable. It may accelerate tracheal extubation, shorten the length of ICU stay, and simplify ventilation management in patients after fast-track CABG.
ObjectiveTo evaluate the predictive value of the diaphragm ultrasound for weaning from mechanical ventilation.MethodsThe patients who received mechanical ventilation in Fujian Provincial Hospital between February 2016 to December 2017 and met the criteria for a T-tube spontaneous breathing trial were included in the study. Then right diaphragmatic displacement (DD) and diaphragmatic thickening fraction (DTF) were evaluated using M-mode ultrasonography as well as the rapid shallow breathing index (RSBI, the ratio of respiratory rate to tidal volume). A new index was named as the diaphragmatic-RSBI (D-RSBI, the ratio of respiratory rate to DD). The patients were classified into a success group or a failure group according to the weaning outcomes. The receiver operating characteristic (ROC) curves were calculated to evaluate the predictive performance of each index.ResultsFifty-nine patients were weaned successfully and failure of weaning was found in 29 patients. There were no statistically significant differences in pre-weaning parameters including age, sex, systolic blood pressure, diastolic blood pressure, blood lipid index (total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, triglyceride), or fast blood glucose between the weaning success group and the weaning failure group (P>0.05), but there were statistically significant differences in body mass index and acute physiology and chronic health condition Ⅱ score between two groups (P<0.05). DD [(13.44±3.23)mm vs. (10.28±2.82)mm, DTF [(32.43±12.35)% vs. (27.64±5.77)%, P<0.05] and D-RSBI [(1.49±0.47) breaths·min–1·mm–1 vs. (2.55±0.87) breaths·min–1·mm–1, P<0.05] differed significantly between the weaning success group and the weaning failure group. A cutoff of DTF≥27.9% yielded a sensitivity of 98.3%, a specificity of 62.1%, and an area under the ROC curve (AUC) of 0.873. A cutoff of D-RSBI≤1.73 breaths·min–1·mm–1 yielded a sensitivity of 76.3%, a specificity of 93.1%, and an AUC of 0.887. By comparison, when RSBI was ≤50.9 breaths·min–1·mm–1, there was a sensitivity of 91.5%, a specificity of 86.2%, and an AUC of 0.927. There was no statistically significant difference in AUC between D-RSBI and RSBI (P>0.05).ConclusionsDiaphragm ultrasound is feasible to predict the outcome of weaning. DTF and D-RSBI are as same accurate as the traditional RSBI in predicting the weaning outcome, but more objective and suitable for clinical application.
Objective To analyze the prognostic factors in the postoperative patients with prolonged mechanical ventilation after extracorporeal circulation.Methods From Oct 2004 to Oct 2007,35 cases of postoperative patients after extracorporeal circulation required mechanical ventilation for ≥24 hours in ICU were enrolled.The patients were divided into death group and survival group.Preoperative variables including blood glucose,serum albumin,creatinine and ejection fraction(EF),intra-operative variables such as cardiopulmonary bypass(CPB) duration,aortic cross clamp(ACC) time,blood transfusion,and postoperative variables such as vital sign arrival at ICU,renal function,drainage in first 24 hours,APACHEⅡ score,ventilation duration were analyzed retrospectively.Results There were significant differences in blood glucose,serum albumin,EF,CPB,ACC,fresh frozen plasma transfusion,APACHEⅡ,creatinine,APTT and oxygenation index between the death group(12 cases,34.29%) and the survival group(23 cases,65.71%).Stepwise logistic regression analysis indicated that EF(OR=0.7973,95%CI 0.6417-0.9906) and APACHEⅡ(OR=1.8588,95%CI 1.1071-3.1210) were predictors of prognosis.Conclusions High mortality is found in postoperative patients after extracorporeal circulation with prolonged mechanical ventilation.The main predictors of prognosis were EF and APACHEⅡ.It’s important to assess preoperative condition for cardiac surgical patients completely and provide more intensive perioperative care.
Objective To examine the adrenal function of critically ill patients received mechanical ventilation, and explore the relationship between the occurrence of relative adrenal insufficiency ( RAI) and weaning outcome.Methods Critically ill patients who were mechanically ventilated over 48 hours were enrolled in this study. Every patient was given one shot of corticotrophin 250 μg intravenously on the first day of admission and the first day of spontaneous-breathing-trial ( SBT) . Plasma contisol level was detected by radio-immunoassay before ( T0 ) and 30 minutes ( T30 ) after the shot. Meanwhile the following parameters were recorded including APACHEⅡ, age, and cause of disease, etc. RAI was defined as the difference between T0 and T30 ≤9 μg/dL. Receiver operating characteristic ( ROC) curve was used to evaluate the accuracy of the indicators towards the weaning outcome. Results A total of 45 patients with mechanical ventilation were recruited. The successful weaning group consisted 29 patients and the failure weaning group consisted 16 patients. The incidence of RAI in the successful weaning group ( 37.9% , 11/ 29) was significantly lower than that in the failure weaning group ( 75.0% , 12 /16) ( P=0. 017) . On the first day of admission, there was no significant difference of Δcortisol between the successful weaning group and the failure weaning group [ ( 10.3 ±5.7) μg/dL vs. ( 7.5 ±4.5) μg/dL, P=0.100) . On the first SBT day, Δcortisol of the successful weaning group was significantly higher than that in the failure weaning group [ ( 10.9 ±5.1) μg/dL vs. ( 4.9 ±2.9) μg/dL, P= 0.043] . Logistic regression analysis showed that Δcortisol was an independent risk factor of weaning. ROC curve analysis showed that on the first SBT day, the area under the curve of Δcortisol was 0.872; The sensitivity and the specificity of accurate judgmentwere 0.813 and 0.828 if Δcortisol ≤6. 95 μg/dL. Conclusions The occurrence of RAI is common in critically ill patients with mechanical ventilation. The adrenal function affects the outcome of weaning, and Δcortisol may be used as an important predictive indicator for weaning outcome.
Objective To analyze the risk factors for duration of mechanical ventilation in critically ill patients. Methods Ninety-six patients who received mechanical ventilation from January 2011 to December 2011 in intensive care unit were recruited in the study. The clinical data were collected retrospectively including the general condition, underlying diseases, vital signs before ventilation, laboratory examination, and APACHEⅡ score of the patients, etc. According to ventilation time, the patients were divided into a long-term group ( n = 41) and a short-term group ( n = 55) . Risk factors were screened by univariate analysis, then analyzed by logistic regression method.Results Univariate analysis revealed that the differences of temperature, respiratory index, PaCO2 , white blood cell count ( WBC) , plasma albumin ( ALB) , blood urea nitrogen ( BUN) , pulmonary artery wedge pressure ( PAWP) , APACHEⅡ, sex, lung infection in X-ray, abdominal distention, and complications between two groups were significant.With logistic multiple regression analysis, the lower level of ALB, higher level of PAWP, lung infection in X-ray, APACHE Ⅱ score, abdominal distention, and complications were independent predictors of long-term mechanical ventilation ( P lt;0. 05) . Conclusion Early improving the nutritional status and cardiac function, control infection effectively, keep stool patency, and avoid complications may shorten the duration of mechanical ventilation in critically ill patients.