Objective To observe the posterior condylar offset (PCO) changes and anteroposterior femorotibial translation, to investigate the influence of them on the maximum knee range of flexion (ROF) in patients with posterior cruciatesacrificingself al ignment bearing total knee arthroplasty (TKA). Methods The cl inical data were analyzed retrospectively from 40 patients (40 knees) undergoing primary unilateral TC-PLUSTM SB posterior cruciate-sacrificing self al ignment andbearing TKA for osteoarthritis between January 2007 and June 2009. There were 18 males and 22 females with an average age of 70.6 years (range, 56-87 years). The disease duration was 5-14 years (mean, 9.1 years). The locations were the left side in 11 cases and the right side in 29 cases. Preoperative knee society score (KSS) and ROF were 48.0 ± 5.5 and (77.9 ± 9.0)°, respectively. The X-ray films were taken to measure PCO and anteroposterior femorotibial translation. Multi ple regression analysis was performed based on both the anteroposterior femorotibial translation and PCO changes as the independent variable, and maximum knee flexion as the dependent variable. Results All incisions healed by first intention. The patients were followed up 12-19 months (mean, 14.7 months). At last follow-up, there were significant differences in the KSS (91.9 ± 3.7, t=— 77.600, P=0.000), the ROF [(102.0 ± 9.3)°, t=— 23.105, P=0.000] when compared with preoperative values. Significant difference was observed in PCO (t=3.565, P=0.001) between before operation [(31.6 ± 5.5) mm] and at last follow-up [(30.6 ± 5.9) mm]. At ast follow-up, the anteroposterior femorotibial translation was (— 1.2 ± 2.1) mm (95%CI: — 1.9 mm to — 0.6 mm); femoral roll forward occurred in 27 cases (67.5%), no roll in 1 case (2.5%), and femoral roll back in 12 cases (30.0%). By multiple regression analysis (Stepwise method), the regression equation was establ ished (R=0.785, R2=0.617, F=61.128, P=0.000). Anteroposterior femorotibial translation could be introducted into the equation (t=7.818, P=0.000), but PCO changes were removed from the equation (t=1.471, P=0.150). Regression equation was y=25.587+2.349x. Conclusion Kinematics after TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA with posterior cruciate l igament-sacrificing show mostly roll forwardof the femur relative to the tibia, which have a negative effect on postoperative range of motion. There is no correlation between PCO changes and postoperative change in ROF in TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA.
Objective
To review the progress of total ankle arthroplasty (TAA) in treatment of end-stage ankle osteoarthritis (AOA).
Methods
The domestic and foreign literatures about TAA in recent years were reviewed. The current status and progress of TAA were summarized from the results of traditional and computer-assisted TAA clinical outcomes.
Results
End-stage AOA often leads to severe pain and dysfunction, and arthrodesis is still the main selective treatment option. In recent years, with the advancement of surgical techniques and prosthesis design, TAA which can remain joint mobility has increased gradually, and the surgical results also have significant progress. Accurate prosthesis implant and mechanical alignment restoration are critical factors for TAA, and surgery-related malalignment is correlative to the prosthesis failure. Computer assisted patient-specific guide can simplify the TAA procedures and obtain the accuracy of tibia and talus osteotomy.
Conclusion
The clinical efficiency of preoperative CT based patient-specific guide technology for TAA needs further clinical follow-up. Meanwhile, it is necessary to further develop intraoperative navigation and robotic surgery system suitable for TAA.
Objective To review the advance in the researchand clinical application of the tibial rotational alignment technique in the total knee arthroplasty in China and abroad. Methods The recent literature concerned with the tibial rotational alignment technique in the totalknee arthroplasty was extensively reviewed and briefly summarized. Results According to the literature reviewed, the traditional tibial rotational references for the total knee arthroplasty were affected by many factors, so that the references were not accurate enough. There have been no unified references.ConclusionChoosing the range from the medial border of the tibial tubercle to the medial 1/3 of the tibial tubercle, decided by the degrees of the varus deformities and the valgus deformities, to determine the rotaional alignment of the tibial component will create an optimal tibiofemoral rotational alignment.
ObjectiveTo observe the character of spino-pelvic sagittal alignment in patients with high-grade L5 isthmic spondylolisthesis, and to analyze the sagittal alignment alteration after operation.
MethodBetween January 2009 and June 2014, 25 patients with high-grade L5 isthmic spondylolisthesis underwent posterior surgery, and the clinical data were retrospectively analyzed as study group. There were 14 males and 11 females with a mean age of 42.5 years (range, 20-65 years). The mean disease duration was 6 months (range, 3-12 months). According to the Meyerding evaluating system, 15 cases were rated as degree III, and 10 cases as degree IV. Eighty healthy adult volunteers were recruited simultaneously as control group. The lumbar sacral angle (LSA), pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), lumbar lordosis (LL), thoracic kyphosis (TK), and sagittal vertical axis (SVA) were measured on preoperative and last follow-up standing full length lateral X-ray films. And these parameters were compared between study group (preoperative parameters) and control group. Then the patients in study group were divided into 2 subgroups according to Hresko's method:the balanced pelvis subgroup (n=14) and unbalanced pelvis subgroup (n=11) . The sagittal parameters were compared between 2 subgroups, and the alteration of sagittal parameters before surgery and at last follow-up was analyzed in each subgroup respectively.
ResultsAll patients in study group were followed up 18 months on average (range, 6-48 months). After surgery, spondylolisthesis was reduced from degree III to degree 0 in 12 cases and to degree I in 3 cases, and from degree IV to degree 0 in 6 cases and to degree I in 4 cases. Bone fusion was obtained in all patients at last follow-up. The preoperative PI, SS, PT, and SVA of study group were significantly greater than those of control group (P<0.05) , while the TK was significantly smaller than that of control group (P<0.05) . In the balanced pelvis subgroup, LSA, LL, and SVA at last follow-up significantly decreased while TK significantly increased when compared with preoperative ones (P<0.05) . In the unbalanced pelvis subgroup, LSA, PT, and SVA at last follow-up significantly decreased while SS, LL, and TK significantly increased when compared with preoperative ones (P<0.05) . The preoperative LSA and PT in the unbalanced pelvis subgroup were significantly greater, while SS, LL, and TK were significantly smaller than those of balanced pelvis subgroup (P<0.05) ; while at last follow-up, significant differentce was found only in LSA between 2 subgroups (P<0.05) .
ConclusionsThe LSA should be paid more attention in surgery to assure recovery of the sagittal balance because patients with high-grade L5 isthmic spondylolisthesis have greater PI, abnormal lumbosacral kyphosis, and sagittal imbalance.
ObjectiveTo summarize the methods of tibial prosthesis rotation alignment in total knee arthroplasty, and provide reference for clinicians to select and further study the methods of tibial prosthesis rotation alignment.MethodsThe advantages and disadvantages of various tibial prosthesis rotation alignment methods were analyzed and summarized by referring to the relevant literature at home and abroad in recent years.ResultsThere are many methods for tibial prosthesis rotation alignment, including reference to relevant anatomical landmarks, range of motion (ROM) technique, computer-assisted navigation, and personalized osteotomy. The inner one-third of the tibial tuberosity is a more accurate reference anatomical landmark, but the obesity, severe knee deformity and dysplasia have impacts on the precise placement of the tibial prosthesis. ROM technique do not need to refer to the anatomical landmark of the tibia, and aren’t affected by landmark variation. It can be used for severe knee valgus deformity and the landmarks that are difficult to identify. However, it may cause internal rotation of tibial prosthesis. Computer- assisted navigation and personalized osteotomy can achieve more accurate alignment in sagittal, coronal, and rotational alignment of femoral prosthesis. However, due to the lack of reliable anatomical landmarkers related to tibia fixation, it is still controversial whether it can help the alignment of tibial prosthesis rotation.ConclusionThe surgeon should master the methods of rotation and alignment of tibial prosthesis, make preoperative plans, select appropriate alignment methods for different patients, and achieve individualization. Meanwhile, several anatomical landmarkers should be referred to properly during the operation, which can be used to detect the correct placement of tibial prosthesis and avoid large rotation error.
ObjectiveTo investigate the improvement of femoral rotation alignment in total knee arthroplasty (TKA) by robotic-arm assisted positioning and osteotomy and its short-term effectiveness.MethodsBetween June 2020 and November 2020, 60 patients (60 knees) with advanced osteoarthritis of the knee, who met the selection criteria, were selected as the study subjects. Patients were randomly divided into two groups according to the random number table method, with 30 patients in each group. Patients were treated with robotic-arm assisted TKA (RATKA) in trial group, and with conventional TKA in control group. There was no significant difference in gender, age, side and course of osteoarthritis, body mass index, and the preoperative hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), posterior condylar angle (PCA), knee society score-knee (KSS-K) and KSS-function (KSS-F) scores between the two groups (P>0.05). The clinical (KSS-K, KSS-F scores) and imaging (HKA, LDFA, MPTA, PCA) evaluation indexes of the knee joints were compared between the two groups at 3 months after operation.ResultsAll patients were successfully operated. The incisions in the two groups healed by first intention, with no complications related to the operation. Patients in the two groups were followed up 3-6 months, with an average of 3.9 months. KSS-K and KSS-F scores of the two groups at 3 months after operation were significantly higher than those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05). X-ray re-examination showed that the prosthesis was in good position, and no prosthesis loosening or sinking occurred. HKA, MPTA, and PCA significantly improved in both groups at 3 months after operation (P<0.05) except LDFA. There was no significant difference in HKA, LDFA, and MPTA between the two groups (P>0.05). PCA in trial group was significantly smaller than that in control group (t=2.635, P=0.010).ConclusionRATKA can not only correct knee deformity, relieve pain, improve the quality of life, but also achieve the goal of restoring accurate femoral rotation alignment. There was no adverse event after short-term follow-up and the effectiveness was satisfactory.
ObjectiveTo explore the characteristics and treatment of intertrochanteric fracture, which the proximal part displaced forwardly and angularly.MethodsBetween March 2015 and March 2016, 40 patients with intertrochanteric fracture with forwardly and angularly displaced proximal part were treated with open reduction and intramedullary nailing fixation. There were 11 males and 29 females with the age of 56-87 years (mean, 75.7 years). The causes of injury included traffic accident in 1 case and fall in 39 cases. The body mass index was 18.9-33.8 kg/m2 (mean, 24.3 kg/m2). The time from injury to admission was 2-360 hours. The type of fracture according to AO-OTA classification was A1.2 type in 7 cases, A1.3 type in 1 case, A2.1 type in 6 cases, A2.2 type in 9 cases, A2.3 type in 12 cases, A3.2 type in 2 cases, and A3.3 type in 3 cases. The haemoglobin (Hb) value at admission and the lowest values before and after operation were recorded; the amount of transfused-blood during hospital stay and visible blood loss around operation were recorded. The short-form 36 health survey scale (SF-36) before injury and at 12 weeks after operation were recorded for evaluating the quality of living; the visual analogue scale (VAS) score at admission and at 2 days after operation were recorded for evaluating the degree of pain, the fracture union was evaluated by X-ray film and clinical examination, and the Harris hip scale were used to evaluate the injuried hip function at 12 weeks.ResultsThe lowest Hb value before operation was (99.10±16.48) g/L, which was significantly lower than that at admission[(114.33±14.93) g/L](t=9.134, P=0.000). Eleven patients were treated with blood transfusion at amount of (520.00±269.98) mL before operation. The amount of transfused-blood during operation was (569.23±207.94) mL, and intraoperative blood loss was (373.08±154.68) mL. The lowest Hb value was (105.41±13.36) g/L after operation, and 8 patients were treated with second blood transfusion at amount of (500.00±185.16) mL. The reduction of fracture was rated as excellent in 16 cases, good in 18 cases, and poor in 6 cases according to the modified Baumgaertner criteria at 3 days after operation. Forty cases were followed up 12-15 weeks (mean, 12.8 weeks). No infection occurred. The VAS score at 2 days after operation was 3.2±0.5, which was significantly improved when compared with the value at admission (8.2±0.5) (t=37.500, P=0.000). At 12 weeks after operation, all the fractures healed; the Harris score was 82.5±6.9; and the SF-36 score was 51.4±11.5, which was significantly decreased when compared with the score before injury (54.9±11.5) (t=18.901, P=0.000). There were delirium in 4 cases, pneumonia in 8 cases, urinary infection in 5 cases, and venous thrombosis in 4 cases after operation. And all patients cured after corresponding treatment.ConclusionIntertrochanteric fracture with forwardly and angularly displaced proximal part is a type of unstable fracture, and it is difficult to reduction. It is necessary to achieve a good fracture reduction by means of auxiliary instrument. The anatomical alignment is the primary condition for the good effectiveness, and the anemia before and after the operation must be corrected.
Objective To explore the coronal alignment of tibial prosthesis after osteotomy using personalized extramedullary positioning technique on tibia side in total knee arthroplasty (TKA). Methods A clinical data of 170 patients (210 knees) who underwent primary TKA between January 2020 and June 2021 and met the selection criteria was retrospectively analyzed. Personalized and traditional extramedullary positioning techniques were used in 93 cases (114 knees, personalized positioning group) and 77 cases (96 knees, traditional positioning group), respectively. The personalized extramedullary positioning was based on the anatomical characteristics of the tibia, a personalized positioning point was selected as the proximal extramedullary positioning point on the articular surface of the tibial plateau. There was no significant difference between the two groups in gender, age, body mass index, surgical side, course of osteoarthritis, and Kellgren-Lawrence classification (P>0.05). The preoperative tibial bowing angle (TBA) formed by the proximal and distal tibial coronal anatomical axes in the personalized positioning group was measured and the tibia axis was classified, and the distribution of personalized positioning point was analyzed. The pre- and post-operative hip-knee-ankle angle (HKA), the lateral distal tibial angle (LDTA), and the postoperative tibia component angle (TCA), the excellent rate of tibial prosthesis alignment in coronal position were compared between the two groups. Results In the personalized positioning group, 58 knees (50.88%) were straight tibia, 35 knees (30.70%) were medial bowing tibia, and 21 knees (18.42%) were lateral bowing tibia. The most positioning points located on the highest point of the lateral intercondylar spine (62.07%) in the straight tibia group, while in the medial bowing tibia and lateral bowing tibia groups, most positioning points located in the area between the medial and lateral intercondylar spines (51.43%) and the lateral slope of the lateral intercondylar spine (57.14%), respectively. The difference in HKA between pre- and post-operation in the two groups was significant (P<0.05); while the difference in LDTA was not significant (P>0.05). There was no significant difference in preoperative LDTA and HKA and the difference between pre- and post-operation between groups (P>0.05). But there was significant difference in postoperative TCA between groups (P<0.05). The postoperative tibial plateau prosthesis in the traditional positioning group was more prone to varus than the personalized positioning group. The excellent rates of tibial prosthesis alignment in coronal position were 96.5% (110/114) and 87.5% (84/96) in personalized positioning group and traditional positioning group, respectively, showing a significant difference between groups (χ2=7.652, P=0.006). Conclusion It is feasible to use personalized extramedullary positioning technique for coronal osteotomy on the tibia side in TKA. Compared with the traditional extramedullary positioning technique, the personalized extramedullary positioning technique has a higher excellent rate of tibial prosthesis alignment in coronal position.
Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.
Objective To explore the mid-term effectiveness of combined knee extensor mechanism realignment with bone anchor for recurrent patella dislocation. Methods Between August 2017 and May 2019, 21 patients with recurrent patella dislocation underwent combined knee extensor mechanism realigament with bone anchor and followed up more than 3 years. There were 8 males and 13 females with an average age of 19.4 years (range, 13-26 years). All 21 patients had a history of recurrent patellar dislocation for 2-5 times (median, 3 times), and the disease duration was 1-16 years (mean, 5 years). The preoperative Lysholm score was 67.5±6.3 and the Kujula score was 64.1±7.0. The defect of meniscus, anterior and posterior cruciate ligaments, and medial and lateral collateral ligaments were excluded by MRI examination; CT examination showed that the tibial tuberosity-trochlear groove distance was 2.05-2.56 cm, with an average of 2.16 cm; X-ray examination showed that lower limb force line was abnormal. The effectiveness were evaluated by Lysholm score and Kujula score before operation and at 3 years after operation, and Insall evaluation standard at 3 years after operation. Results All the incisions healed by first intention, and there was no surgical complication such as lower extremity deep vein thrombosis, incision infection, and nerve injury. All 21 patients were followed up 3.0-3.5 years, with an average of 3.2 years. Anteroposterior and lateral X-ray films of the knee joint at 3 years after operation showed that the position of the patella was normal, and the axial X-ray films of the patella (30°, 60°, 90°) showed that the patellofemoral joint had a good relationship. During the follow-up, there was no anchor drop or fracture, no obvious pseudarthrosis formation, and no epiphyseal injury in the minor patients. The Lysholm score was 91.5±7.1 and the Kujula score was 88.1±7.6 at 3 years after operation, which were significantly improved when compared with those before operation (t=11.57, P=0.00; t=12.78, P=0.00). According to the Insall evaluation criteria, 12 cases were excellent, 4 cases were good, 4 cases were fair, and 1 case was poor, with an excellent and good rate of 76.2%. ConclusionCombined knee extensor mechanism realignment with bone anchor is a simple and reliable way to treat the recurrent patella dislocation, with a satisfactory mid-term effectiveness and less complications; however, its long-term effectiveness needs further follow-up.