ObjectiveTo study the biomechanical stability of neckwear-knot-loop-ligature fixation for tibial eminence avulsion fractures by comparing with cannulated screw fixation and suture anchor fixation.
MethodsTwenty-four fresh porcine knee joints were selected. After the model of tibial eminence avulsion fracture (type Ⅲ) was made, 24 samples were randomly divided into 3 groups: neckwear-knot-loop-ligature group (group A), cannulated screw group (group B), and suture anchor group (group C), 8 samples in each group. The Universal electromagnetic and mechanical testing machines were used for the biomechanical tests. After 200 cyclic tests, pull-out test was done until fixation failure. The maximum failure load, yield load, stiffness, and displacement were measured.
ResultsFailure mode: the displacement was beyond limit in 8 samples of group A; screws extraction (5 samples) and bone fragment re-fracture (3 samples) were observed in group B; and suture anchor extraction (4 samples), suture rupture (3 samples), and suture thread cutting (1 sample) were found in group C. Biomechanical test: From groups A to C, the maximum failure load and yield load showed significant decreasing tendency (P<0.05), but the displacements showed significant increasing tendency (P<0.05). The stiffness also gradually decreased, but differences was not significant (P>0.05).
ConclusionCompared with cannulated screw and suture anchor, neckwear-knot-loop-ligature fixation for tibial eminence avulsion fracture has good biomechanical performance and the advantages of firm fixation and simple operation.
ObjectiveTo compare the early effectiveness of minimally invasive open reduction and internal fixation via posterior median approach versus arthroscopic double-tunnel suture fixation in treatment of tibial avulsion fracture of the posterior cruciate ligament (PCL).MethodsA clinical data of 31 patients with the tibial avulsion fracture of the PCL and met the criteria between January 2015 and January 2019 was retrospectively analyzed. Nineteen patients (group A) were treated with open reduction and internal fixation with cannulated screw via posterior median approach. The other 12 patients (group B) were treated with arthroscopic double-tunnel suture fixation technique. There was no significant difference between the two groups (P>0.05) in the gender, age, side of effected limb, the injury cause, the time from injury to operation, the combined meniscus injury, Meyers & McKeever classification and preoperative Lysholm score, Tegner score, International Knee Documentation Committee (IKDC) score, and the difference of tibial posterior displacement between bilateral knees. The operation time, postoperative complications, fracture healing, and the difference of tibial posterior displacement between bilateral knees, Lysholm score, Tegner score, and IKDC score were recorded.ResultsGroup B spent significantly longer operation time than group A (t=7.347, P=0.000). No postoperative complication occurred in group B, and 1 patient in group A had a screw breakage. All patients were followed up 6-36 months (mean, 22 months). X-ray films showed that all fractures healed at 3 months after operation. At last follow-up, there was no significant difference in the patients with normal knee range of motion between the two groups (P=0.510). At last follow-up, the difference of tibial posterior displacement between bilateral knees, Lysholm score, Tegner score, and IKDC score in the two groups were superior to those before operation (P<0.05); while there was no significant difference between the two groups (P>0.05).ConclusionFor the tibial avulsion fracture of PCL, the minimally invasive open reduction and internal fixation and arthroscopic double-tunnel suture fixation can obtain similar early effectiveness. However, arthroscopic surgery has the advantages of being able to simultaneously deal with intra-articular combined injuries, avoiding internal fixator complications, and eliminating the need for secondary operation.
ObjectiveTo compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation. Methods The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups (P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function. ResultsThere was no significant difference in operation time between the two groups (P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference (t=?0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values (P<0.05). However, there was no significant difference in the improvement value between the two groups (P>0.05). ConclusionFor PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.
Objective
To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate.
Methods
Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate.
Results
Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000).
Conclusion
The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.
Objective To investigate the early effectiveness of three-point suture technique in treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture by arthroscopy. Methods Between January 2016 and December 2017, 12 patients with ACL tibial eminence avulsion fractures underwent arthroscopic fixation of avulsion fractures with Ethibon suture using three-point suture technique. There were 9 males and 3 females, with an average of 36.4 years (range, 18-50 years). The fracture caused by traffic accident in 10 cases and sports in 2 cases. Among them, 1 patient was old fracture and 11 was fresh fracture. According to the modified Meyers-McKeever classification criteria, the fractures were rated as type Ⅲ in 7 cases and type Ⅳ in 5 cases. There were 2 cases of medial collateral ligament injury and medial meniscus injury. The preoperative International Knee Documentation Committee (IKDC) score was 37.9±4.7 and Lysholm score was 46.0±3.7. Results All operations completed smoothly. The operation time was 45-70 minutes (mean, 61.3 minutes). The incisions healed by first intention in all patients. The hospitalization stays ranged from 4 to 9 days (mean, 5 days). All patients were followed up 3-20 months (mean, 9.3 months). The anterior drawer test, Lachman test, and axis shift test in all patients were negative after operation. At last follow-up, the IKDC score was 89.7±2.5 and Lysholm score was 90.2±1.9, which were significantly higher than those before operation (t=–30.94, P=0.00; t=–33.03, P=0.00). At last follow-up, the X-ray films showed 9 cases of fracture anatomical reduction and 3 cases of almost anatomical reduction, and 12 cases of fracture healing. Conclusion For ACL tibial eminence avulsion fracture, arthroscopic three-point suture technique can effectively restore the stability of knee joint and obtain satisfactory early effectiveness.
ObjectiveTo investigate the effectiveness of arthroscopic multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of anterior cruciate ligament (ACL) involving the anterior root of lateral meniscus (LM). Methods A retrospective analysis was conducted on the clinical data of 28 patients with tibial insertion avulsion fracture of ACL involving the anterior root of LM who were treated with arthroscopic multi-point fixation with anchor and suture between October 2017 and January 2023. There were 12 males and 16 females with the mean age of 26 years (range, 13-57 years). There were 20 cases of sports injury and 8 cases of traffic accident injury. In 2 cases of old fracture, the time from injury to operation was 45 days and 90 days, respectively; in 26 cases of fresh fracture, the time from injury to operation was 3-20 days (mean, 6.7 days). According to the Meyers-McKeever classification, there were 4 cases of type Ⅱ, 11 cases of type Ⅲ, and 13 cases of type Ⅳ. The preoperative Lysholm knee function score was 42.1±9.0, the International Knee Documentation Committee (IKDC) score was 40.0±7.3, and the Tegner score was 0.7±0.7. ResultsAll operations were successfully completed, and the incisions healed by first intention. All the 28 patients were followed up 5-60 months (mean, 20.4 months). During the follow-up, there was nocomplication such as infection, vascular or nerve injury, loosening or breakage of internal fixator, or stiffness of knee joint. Postoperative X-ray films showed satisfactory fracture reduction and firm fixation. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 10.3 weeks). At last follow-up, Lachman test and anterior drawer test were negative. At last follow-up, Lysholm knee function score was 92.4±5.5, IKDC score was 91.6±4.4, and Tegner score was 5.2±1.1, which significantly improved when compared with preoperative scores (t=?22.899, P<0.001; t=?29.870, P<0.001; t=?19.979, P<0.001). ConclusionMulti-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of ACL involving the anterior root of LM can not only fix the LM, but also effectively reduce and fix the avulsion fracture, which can obtain good effectiveness.
ObjectiveTo analyze the possible injury mechanisms in patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint, and to discuss their treatment and prognosis. Methods Retrospective analysis was made on the clinical data of 4 patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint admitted between September 2014 and September 2020, including 3 males and 1 female with an average age of 20.7 years (range, 13-32 years). There were 2 cases of dorsal avulsion fracture of the capitellum combined with medial dislocation of the elbow joint and 2 cases of dorsal avulsion fracture of the capitellum and anterior medial fracture of the coronoid process combined with posterior medial subluxation of the elbow joint. Closed reduction was performed in 3 patients with fresh fracture combined with dislocation, then 2 cases were fixed with tension band and 1 case was fixed with tension band combined with Acumed coronoid anatomic plate. And in patient with old fracture nonunion, the coronoid process was fixed with 1 screw, then the humeral sclerotic bone mass was removed, and finally the lateral collateral ligament was repaired and a hinged external fixator was added. Results All the incisions healed by first intention without early complications such as infection or peripheral nerve injury. The 4 patients were followed up 13-30 months (mean, 20.8 months). The fractures all healed with a healing time of 70-90 days (mean, 79.5 days). At 6 months after operation, heterotopic ossification was seen in the posterior aspect of the right elbow joint in 1 case, and the alkaline phosphatase level was normal (67 U/L); the tension band was removed to clear the heterotopic ossification and the elbow joint was released. The rest of the patients had no heterotopic ossification. At last follow-up, all patients had good functional recovery of the elbow joint, with a Mayo score of 85-100 (mean, 92.5), and the excellent and good rate was 100%. The elbow flexion range of motion was 120°-135°, the extension range of motion was 10°-20°, and the pronation and supination range of motion were all 75°-85°. Conclusion Dorsal avulsion fractures of the capitellum combined with medial or posterior medial dislocation of the elbow may be due to simple varus stress. If an anteromedial coronoid facet fracture also occurs, it may be for the varus posteromedial rotatory instability, which is the opposite mechanism to that of an Osborne-Cotterill lesion. For fresh dorsal avulsion fractures of the capitellum, tension band fixation can be used with good results.
Objective To investigate the effectiveness of knee arthroscopy with wire anchor nailing composite double pulley technique in the treatment of anterior cruciate ligament (ACL) tibial avulsion fracture involving the anterior root of the lateral meniscus (LM). Methods Clinical data of 35 patients with ACL tibial avulsion fracture involving the anterior root of the LM admitted between January 2019 and September 2023 and met the selection criteria were retrospectively analysed. There were 20 males and 15 females; ages ranged from 10 to 57 years, with a mean of 29 years. The time from injury to surgery ranged from 3 to 20 days, with a mean of 9.6 days. Meyers-McKeever classification included 5 cases of type Ⅱ, 12 cases of type Ⅲ, and 18 cases of type Ⅳ. Preoperative anterior knee instability Lachman test and anterior drawer test were positive. The anterior root of the LM as well as the avulsion fracture block were fixed using suture anchor nails compounded with double pulley technique under arthroscopy. Postoperative X-ray films were performed to assess fracture healing; knee stability was assessed using the anterior drawer test and Lachman test, anterior laxity of the knee was measured by KT-2000, and knee function was assessed using the Lysholm score and the International Knee Documentation Committee (IKDC) score; at last follow-up, the recovery of the meniscus was assessed using the McMurry test and knee hyperextension test. Results All the patients were successfully operated, the operation time ranged from 56 to 78 minutes,with an average of 67.6 minutes, and there was no nerve or blood vessel injury during operation. Thirty-five cases were followed up 12-18 months with an average of 15.1 months. During the follow-up, there was no infection, knee stiffness, loosening of internal fixation, fracture displacement, or re-fracture. The fractures all healed, with a clinical healing time of 8-15 weeks, averaging 10.9 weeks. At last follow-up, 4 patients had weakly positive anterior drawer test and Lachman test, and the rest were negative; McMurry test and knee hyperextension test were negative; no patient complained of knee extension pain or straightening obstacles, and all the patients resumed their normal life or sports and labour; 16 patients with unclosed epiphyses did not have any epiphyseal injuries or growth disorders. Lysholm score, IKDC score, and KT-2000 anterior knee laxity at last follow-up significantly improved when compared with preoperative ones (P<0.05). Conclusion The treatment of ACL tibial avulsion fracture involving the anterior root of the LM with suture anchor composite double pulley technique can effectively fix the anterior root of the LM while fixing the avulsion fracture block, and better restore the function and stability of the knee joint.
Objective
To explore effectiveness of suture-bridge fixation under arthroscopy in treatment of tibial eminence avulsion fracture of anterior cruciate ligament in adolescents.
Methods
Between June 2013 and October 2016, 18 adolescent patients suffered from tibial eminence avulsion fracture of anterior cruciate ligament were treated by suture-bridge fixation under arthroscopy. There were 11 males and 7 females with an average age of 12.5 years (range, 5-17 years). The injury caused by bruise in 6 cases, by sprain in 4 cases, and by sport injury in 8 cases. The interval between injury and admission ranged from 2 hours to 10 months (median, 2 months). The results of preoperative Lachman and anterior drawer tests were positive. There were 10 cases of knee pain, 4 cases of knee extension limitation, and 4 cases of knee extension without strength. According to the Meyer-McKeever classification criteria, 12 cases were type Ⅱ and 6 cases were type Ⅲ.
Results
All incisions healed by first intention. All 18 patients were followed up 10-18 months after operation, with an average of 12 months. Postoperative X-ray films showed that all fractures healed after 6-12 weeks (mean, 8 weeks). The results of postoperative Lachman and anterior drawer tests were negative. At last follow-up, the Lysholm knee score was 90.1±5.0 and 93.1±6.2 for affected and unaffected sides, respectively, showing no signifi cant difference (t=0.669, P=0.184). There was no premature closure of skeleton or leg length discrepancy deformity.
Conclusion
For tibial eminence avulsion fracture of anterior cruciate ligament in adolescents, the suture-bridge fixation under arthroscopy is an effective method with many advantages, such as minimal invasion, reliable fixation, good fracture healing, and no need for second operation to remove implants.
Objective To investigate the effectiveness of three-needle and two-cable structure in the treatment of inferior patellar pole avulsion fractures. Methods A clinical data of 62 patients with inferior patellar pole avulsion fractures who were admitted between January 2023 and December 2023 and met the selection criteria was retrospectively analyzed. Among them, the fractures were fixed with three-needle and two-cable structure in 32 patients (observation group) and traditional steel wire tension band in 30 cases (control group). There was no significant difference in the baseline data of age, gender, side of the affected limb, cause of injury, and disease duration between the two groups (P>0.05). The operation time, fracture healing and healing time, patellar height (Insall-Salvati index), occurrence of complications, knee range of motion, and B?stman score at last follow-up were compared between the two groups. Results The operation time of the observation group was significantly shorter than that of the control group (P<0.05). Patients in both groups were followed up 6-12 months (mean, 10.4 months). X-ray films re-examination showed that all fractures healed, and the fracture healing time was significantly shorter in observation group than in control group (P<0.05); no significant difference was found in Insall-Salvati index between the two groups (P>0.05). During follow-up, the complications occurred in 2 cases (6.25%) of observation group and in 9 cases (30.00%) of control group, and the difference in the incidences between the two groups was significant (P<0.05). At last follow-up, the range of motion and B?stman score of the knee joint in observation group were significantly superior to control group (P<0.05). Conclusion Compared with the traditional steel wire tension band fixation, the three-needle and two-cable structure fixation of the inferior patellar pole avulsion fractures is firm, which allows the knee joint to move early after operation and is conducive to the recovery of knee joint function.