        find Keyword "blood pump" 14 results
        • Progress of the Third Generation Blood Pumps

          Abstract: The ventricle assist device has emerged as an important therapeutic option in the treatment of both acute and chronic heart failure. The blood pumps which are the major components of ventricle assist devices have also progressed to the third generation. The magnetic and/or liquid levitation technologies have been applied into the third generation blood pumps. The impellers which drive blood are levitated in the blood pumps. The third generation blood pumps are mainly composed of the levitation system and the driving system. The development of the third generation blood pumps has three stages: the stage of foreign motor indirectly driving the impeller with the levitation and driving system separated, the stage of motor directly driving the impeller with the levitation and driving system separated, and the stage of levitation system integrated with the driving system. As the impellers do not contact with other structures, the third generation blood pumps possess the advantages of low thrombosis, less hemolysis and high energy efficiency ratio. Currently most of the third generation blood pumps are in the research stage, but a few number of them are used in clinical trials or applying stage. In this article, the history, classification, mechanism and research situation of the third generation blood pumps are reviewed.

          Release date:2016-08-30 06:02 Export PDF Favorites Scan
        • Research progress and clinical application of ventricular assist blood pump

          Heart failure is a leading cause of death in human populations. Because of the insufficient numbers of donor hearts, ventricular assist as a way for the treatment of heart failure and its clinical use is increasing. Initially ventricular assist devices were approved as a bridge-to-recovery indication, and these systems are now increasingly being used as a bridge-to-transplant (BTT) , destination therapy (DT) or permanent support. According to the different structure and working mechanism, ventricular assist device is generally divided into three generation. This review makes a summary on the type of blood pump and its research progress in clinical application.

          Release date:2017-01-22 10:15 Export PDF Favorites Scan
        • Experimental Study of Hemolysis in Vitro and Animal Testing for Fu Wai Axial Blood Pump

          Objective To provide a ventricular assist device for patients with heart failure, Fu Wai (FW) axial blood pump was developed for partly or totally to assist the left ventricular function. Vitro hemolysis and animals tests were also employed to test the hydromechanics and hemocompatibility of the FW left ventricular assist devices developed in Fu Wai hospital. Methods Using vitro test loop, FW axial blood pump has been used to evaluate the performance of hemolysis, the pump has also been tested for hemolysis characteristic through five sheep experiments. Results At 8 400 r/min, the pump generates 5 L/min flow against 100 mm Hg, the normalized index of hemolysis (NIH) was0.17±0.06 mg/L. The plasma free hemoglobin of in vivo tests was around 30 mg/dl. Conclusion The results obtained in vitro and in vivo testing indicate an acceptable design for the blood pump, further in vivo tests will be performed before clinical use.

          Release date:2016-08-30 06:05 Export PDF Favorites Scan
        • Research on Magnetic Coupling Centrifugal Blood Pump Control Based on a Self-tuning Fuzzy PI Algorithm

          The purpose of this paper is to report the research and design of control system of magnetic coupling centrifugal blood pump in our laboratory, and to briefly describe the structure of the magnetic coupling centrifugal blood pump and principles of the body circulation model. The performance of blood pump is not only related to materials and structure, but also depends on the control algorithm. We studied the algorithm about motor current double-loop control for brushless DC motor. In order to make the algorithm adjust parameter change in different situations, we used the self-tuning fuzzy PI control algorithm and gave the details about how to design fuzzy rules. We mainly used Matlab Simulink to simulate the motor control system to test the performance of algorithm, and briefly introduced how to implement these algorithms in hardware system. Finally, by building the platform and conducting experiments, we proved that self-tuning fuzzy PI control algorithm could greatly improve both dynamic and static performance of blood pump and make the motor speed and the blood pump flow stable and adjustable.

          Release date: Export PDF Favorites Scan
        • Numerical study of the effect of geometrical parameters of straight impellers on the flow and hemolysis performance of centrifugal blood pumps

          Red blood cells are destroyed when the shear stress in the blood pump exceeds a threshold, which in turn triggers hemolysis in the patient. The impeller design of centrifugal blood pumps significantly influences the hydraulic characteristics and hemolytic properties of these devices. Based on this premise, the present study employs a multiphase flow approach to numerically simulate centrifugal blood pumps, investigating the performance of pumps with varying numbers of blades and blade deflection angles. This analysis encompassed the examination of flow field characteristics, hydraulic performance, and hemolytic potential. Numerical results indicated that the concentration of red blood cells and elevated shear stresses primarily occurred at the impeller and volute tongue, which drastically increased the risk of hemolysis in these areas. It was found that increasing the number of blades within a certain range enhanced the hydraulic performance of the pump but also raised the potential for hemolysis. Moreover, augmenting the blade deflection angle could improve the hemolytic performance, particularly in pumps with a higher number of blades. The findings from this study can provide valuable insights for the structural improvement and performance enhancement of centrifugal blood pumps.

          Release date:2024-06-21 05:13 Export PDF Favorites Scan
        • Research progress on hemolysis of rotary blood pump

          Hemolysis is one of the main complications associated with the use of ventricular assist devices. The primary factors influencing hemolysis include the shear stress and exposure time experienced by red blood cells. In addition, factors such as local negative pressure and temperature may also impact hemolysis. The different combinations of hemolysis prediction models and their empirical constants lead to significant variations in prediction results; compared to the power-law model, the OPO model better accounts for the complexity of turbulence. In terms of improving hemolytic performance, research has primarily focused on optimizing blood pump structures, such as adjustments to pump gaps, impellers, and guide vanes. A small number of scholars have studied hemolytic performance through control modes of blood pump speed and the selection of blood-compatible materials. This paper reviews the main factors influencing hemolysis, prediction methods, and improvement strategies for rotary blood pumps, which are currently the most widely used. It also discusses the limitations in current hemolysis research and provides an outlook on future research directions.

          Release date:2025-04-02 10:54 Export PDF Favorites Scan
        • Numerical Analysis of Two-stage Axial Blood Pump Based on Blood Damage

          The implantable miniaturized axial blood pump works at a high rotational speed, which increases the risk of blood damage. In this article, we aimed to reduce the possibility of hemolysis and thrombosis by designing a two-stage axial blood pump. Under the operation conditions of flow rate 5 L/min and outlet pressure of 100 mm Hg, we carried out the numerical simulation on the two-stage and single-stage blood pumps to compare the hemolysis and platelet activation state. The results turned out that the hemolysis index of two-stage axial blood pump was better while the platelet activation state was worse than those of single stage design. On the index of hemolysis level and platelet activation state, the design of the two-stage pump with the low and high-head impeller combination was better than the two-stage pump with the equal heads, or the high and low-head impeller combination. In terms of reducing the risk of blood damage for implantable miniaturized axial blood pump, the research result can provide some theoretical basis and new design ideas.

          Release date:2016-10-02 04:55 Export PDF Favorites Scan
        • Progress in the analysis of hemolysis and coagulation models for interventional micro-axial flow blood pumps

          Interventional micro-axial flow blood pump is widely used as an effective treatment for patients with cardiogenic shock. Hemolysis and coagulation are vital concerns in the clinical application of interventional micro-axial flow pumps. This paper reviewed hemolysis and coagulation models for micro-axial flow blood pumps. Firstly, the structural characteristics of commercial interventional micro-axial flow blood pumps and issues related to clinical applications were introduced. Then the basic mechanisms of hemolysis and coagulation were used to study the factors affecting erythrocyte damage and platelet activation in interventional micro-axial flow blood pumps, focusing on the current models of hemolysis and coagulation on different scales (macroscopic, mesoscopic, and microscopic). Since models at different scales have different perspectives on the study of hemolysis and coagulation, a comprehensive analysis combined with multi-scale models is required to fully consider the influence of complex factors of interventional pumps on hemolysis and coagulation.

          Release date: Export PDF Favorites Scan
        • Study on sensorless suction detection method based on the intrinsic parameter of rotary left ventricular assist devices

          The rotary left ventricular assist device (LVAD) has been an effective option for end-stage heart failure. However, while clinically using the LVAD, patients are often at significant risk for ventricular collapse, called suction, mainly due to higher LVAD speeds required for adequate cardiac output. Some proposed suction detection algorithms required the external implantation of sensors, which were not reliable in long-term use due to baseline drift and short lifespan. Therefore, this study presents a new suction detection system only using the LVAD intrinsic blood pump parameter (pump speed) without using any external sensor. Three feature indices are derived from the pump speed and considered as the inputs to four different classifiers to classify the pumping states as no suction or suction. The in-silico results using a combined human circulatory system and LVAD model show that the proposed method can detect ventricular suction effectively, demonstrating that it has high classification accuracy, stability, and robustness. The proposed suction detection system could be an important part in the LVAD for detecting and avoiding suction, while at the same time making the LVAD meet the cardiac output demand for the patients. It could also provide theoretical basis and technology support for designing and optimizing the control system of the LVAD.

          Release date:2019-06-17 04:41 Export PDF Favorites Scan
        • Design of an axial blood pump of diffuser with splitter blades and cantilevered main blades

          An implantable axial blood pump was designed according to the circulation assist requirement of severe heart failure patients of China. The design point was chosen at 3 L/min flow rate with 100 mm Hg pressure rise when the blood pump can provide flow rates of 2-7 L/min. The blood pump with good hemolytic and anti-thrombogenic property at widely operating range was designed by developing a structure that including the spindly rotor impeller structure and the diffuser with splitter blades and cantilevered main blades. Numerical simulation and particle image velocimetry (PIV) experiment were conducted to analyze the hydraulic, flow fields and hemolytic performance of the blood pump. The results showed that the blood pump could provide flow rates of 2-7 L/min with pressure rise of 60.0-151.3 mm Hg when the blood pump rotating from 7 000 to 11 000 r/min. After adding the splitter blades, the separation flow at the suction surface of the diffuser has been reduced efficiently. The cantilever structure changed the blade gap from shroud to hub that reduced the tangential velocity from 6.2 m/s to 4.3-1.1 m/s in blade gap. Moreover, the maximum scalar shear stress of the blood pump was 897.3 Pa, and the averaged scalar shear stress was 37.7 Pa. The hemolysis index of the blood pump was 0.168% calculated with Heuser’s hemolysis model. The PIV and simulated results showed the overall agreement of flow field distribution in diffuser region. The blood damage caused by higher shear stress would be reduced by adopting the spindle rotor impeller and diffuser with splitter blades and cantilevered main blades. The blood could flow smoothly through the axial blood pump with satisfactory hydraulics performance and without separation flow.

          Release date:2019-06-17 04:41 Export PDF Favorites Scan