1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "disinfect" 23 results
        • Research on PDCA Cycle Model in Standardizing the Application of Common Disinfectants

          ObjectiveTo study the effect of PDCA cycle model on the standardization of the application of common disinfectants, in order to promote the management level of hospital disinfection. MethodsBy questionnaire and observation, the study was to learn the knowledge and its application in medical workers on common disinfectants. Based on the results, we tried to regulate effective preventive measures and carry out continuous improvements. ResultAfter the implementation of PDCA cycle model, the awareness rate of the medical staff on disinfection and the application accuracy of disinfectants were significantly increased (P<0.05). ConclusionThe implementation of PDCA cycle model can improve nosocomial infection management level effectively, ensure medical quality management and patients' safety, which is an effective way of management to reduce the rate of nosocomial infection.

          Release date:2016-11-23 05:46 Export PDF Favorites Scan
        • Investigation and Analysis on the Standardization of Surgical Hand-washing and Hand-disinfection

          ObjectiveTo investigate on preoperative hand-washing for analyzing the underlying problems, in purpose of preventing operation-related infection via strengthening the standardization of surgical hand-washing and hand-disinfection. MethodsFrom July to September 2014, surveillance video of pre-operative hand-washing was studied and analyzed. We randomly selected 100 subjects, and assessment was performed based on the self-made surgical hand-washing and hand-disinfection protocol. Grading was done strictly. The passing score was 60 or higher; a score of 70-79 meant good; and a score of 80-100 indicated excellence. ResultsIn the survey, 91 in the 100 subjects were qualified. Among the qualified subjects, there were 53% of excellence and 20% of good. The major problems included erroneous methods, step omissions, time lacking, pollution, wrong flushing method or dry-hand method, and insufficient washing time. ConclusionBased on the survey, the administration department is advised to strengthen the regulatory supervision and education training based on standard surgical hand-washing and hand-disinfection criteria, especially training interns and new staff, in purpose of reducing the incidence of operation-related infection and improving hospitalization management qualities.

          Release date: Export PDF Favorites Scan
        • Safety of hand disinfectants: a systematic review

          ObjectiveTo systematically review the safety of hand disinfectants. MethodsPubMed, EMbase, The Cochrane Library, INAHTA, WanFang Data, CNKI and VIP databases were electronically searched to collect studies on the safety of hand disinfectants from inception to February 1st, 2021. Two reviewers independently screened the literature, extracted data and assessed the risk of bias of the included studies; then, a systematic review was conducted. ResultsA total of 50 studies were included. The reported adverse events were eye and nasal mucosal irritation, hand adverse events with skin itching, rash, erythema, edema and so on. A total of 29 brands such as 3M Avagard and 26 ingredients such as ethanol were reported to be related to the above adverse events. Hand disinfectants containing glycerin, silicone oil, vitamin B, plant extracts and other emollients could reduce the incidence of adverse events. ConclusionCurrent evidence shows that hand disinfectants containing emollients and free from ethanol, chlorhexidine and other ingredients are related to fewer adverse events. Due to the limited quality and quantity of the included studies, more high-quality studies are needed to verify the above conclusion.

          Release date:2022-07-14 01:12 Export PDF Favorites Scan
        • International advances in duodenoscopy reprocessing

          Endoscopic retrograde cholangiopancreatography is one of the main methods for the diagnosis and treatment of biliary tract and pancreatic diseases. Compared with other digestive endoscopes, duodenoscopy has a special structure. Since the outbreaks of nosocomial infections caused by the transmission of multidrug-resistant organism through duodenoscopy in 2010, the reprocessing and design of digestive endoscopes represented by duodenoscopy have faced new challenges. This article reviews the international advances in duodenoscopy reprocessing in the past 10 years including the structural characteristics of duodenoscope, related infection outbreak cases, outbreak control measures, and the use of disposable duodenoscopy, so as to provide guidance and reference for the duodenoscopy reprocessing and related nosocomial infections prevention and control work in China.

          Release date:2024-04-25 02:18 Export PDF Favorites Scan
        • Analysis of high-level disinfection effect of flexible endoscopes in an endoscope center

          ObjectiveTo evaluate the high-level disinfection effect of flexible endoscopes in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu, explore the key links of flexible endoscope cleaning and disinfection, and provide theoretical guarantee and technical support for the next step of the endoscope center work.MethodsWe sampled and monitored the lumens, water and air injection ports and biopsy ports of 19 flexible endoscopes after high-level disinfection in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu. A total of 307 specimens were collected from 108 flexible endoscopes. We compared the disinfection effects of different flexible endoscopes and different sampling sites, and compared the microbial detection status of different flexible endoscopes.ResultsThe qualified rates of disinfection of gastroscopes, colonoscope and duodenoscopy were 79.22%, 86.21% and 100.00%, respectively, and the difference was not statistically significant (P=0.721). The qualified rates of disinfection of the endoscopic lumen, water and air injection port and biopsy port were 87.04%, 93.00% and 94.95%, respectively, and the difference was not statistically significant (χ2=4.585, P=0.101). The qualified rates of the lumen, water and air injection port and biopsy port of gastroscope, colonoscope and duodenoscope were 84.42%, 93.10%, 100.00%, 92.96%, 92.59%, 100.00%, 94.29%, 96.30%, 100.00%, respectively. There was no statistically significant difference in the disinfection effect of various parts of different flexible endoscopes (P>0.05). Bacteriological identification showed that of the 28 specimens with excess bacteriological standards, 16 gram-positive bacteria (57.1%), and 12 gram-negative bacteria (42.9%) were found.ConclusionThe cleaning and disinfection effect of flexible endoscopes has certain defect. Endoscope should be treated in strict accordance with the technical specifications for cleaning and disinfection of the flexible endoscope to further improve the disinfection effect of the flexible endoscope.

          Release date:2021-04-15 05:32 Export PDF Favorites Scan
        • Evaluation of practical experience with medical sewage treatment in medical institutions in China

          ObjectiveTo evaluate the evidence of the experience with medical sewage treatment procedures in medical institutions in China. MethodsDatabases including CNKI, WanFang Data, PubMed, Web of Science, and EBSCO were electronically searched to collect studies on the medical sewage treatment process, flow, and specifications in medical institutions in China. We used the quality evaluation system to classify and grade the experiences based on the principles and methods of evidence-based science and performed a descriptive analysis. ResultsAfter the SARS pandemic in 2003, China systematically established and standardized the technical criteria of medical sewage treatment and discharge. Moreover, a prevention system for the epidemic using medical sewage was constructed, which guaranteed that the quality of medical sewage treatment and discharge would meet the criteria and protect the citizens, and the technical specifications of medical sewage treatment would progress and increase strictly. At present, medical sewage treatment in medical institutions in China was based on mechanical and biological methods, and disinfection was mainly performed using chlorine and its compounds, ozone, and ultraviolet light. ConclusionThe COVID-19 pandemic requires a higher quality of medical sewage treatment and discharge criteria for medical institutions in China. To meet these criteria, all medical institutions in China should check, replace, and update their old facilities; strengthen personnel training and effectively ensure the quality of medical sewage treatment.

          Release date:2022-09-20 10:03 Export PDF Favorites Scan
        • Research on coronavirus disease 2019 field disinfection technology for prevention and control

          The coronavirus disease 2019 (COVID-19) epidemic has had a serious impact in the world. In the absence of vaccines and therapeutic drugs, disinfection has become an important technical means to block the spread of the virus. By analyzing the characteristics of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), we studied a series of disinfection technologies for COVID-19. During the outbreak of COVID-19, Jinan Second Center for Disease Control and Prevention disinfected the houses of the cases to be investigated in a community. The effectiveness of the disinfection technology was verified through the process of disinfection preparation, sampling before disinfection, field disinfection, sampling after disinfection and evaluation of disinfection effect. Compared the data before and after disinfection, the killing rate of the total bacterial colonies in the air and on the surface of the object was more than or equal to 90%, and no SARS-CoV-2 was detected after disinfection. The results show that the disinfection effect of the disinfection technology meets the standard. Finally, through the analysis of the wrong way of disinfection and the harm of over disinfection, the importance of scientific disinfection and precise disinfection are emphasized, and the research has a good guiding value for prevention and control of the epidemic.

          Release date:2020-10-20 05:56 Export PDF Favorites Scan
        • Mechanism of cold atmospheric plasma in treatment of chronic skin ulcer

          Objective To review the mechanism of cold atmospheric plasma (CAP) in the treatment of chronic skin ulcer, providing a new idea for ulcer therapy. Methods The literature about CAP in the treatment of chronic skin ulcers in recent years was extensively screened and reviewed. The treatment principle, active ingredients, and mechanism were summarized. Results CAP is partial ionized gas discharged by plasma generator in high frequency under high voltage. It contains electrons, positive and negative ions, reactive oxygen species, reactive nitrogen species, and ultraviolet rays. In vitro and animal experiments show that the active ingredients contained in CAP can inactive microorganisms, against biofilm, regulate immune-mediated inflammatory, promoting blood flow, stimulate tissue regeneration and epithelial formation in the course of wounds healing. Conclusion CAP play a role in different stages of chronic skin ulcer healing, with good effectiveness and safety, and broad clinical application prospects. But more studies are needed to explore the indications and dosages of CAP therapy.

          Release date:2024-11-13 03:16 Export PDF Favorites Scan
        • Disinfection effect of alcohol-based hand disinfectants for glove surface

          Objective To evaluate the disinfection efficacy of alcohol-based hand disinfectants for medical glove surface in continuous operation, and explore approaches of improving hand hygiene compliance. Methods Between March and July 2015, and between March and July 2016, all the nurses (n=5) in Blood Collection Room of Outpatient Department with many patients and frequent sterile operation needed were included in this study. Nurses wearing gloves for hand hygiene and disinfection between March and July 2016 were regarded as the observation group, and those who used alcohol-based disinfectants for routine hand hygiene without gloves between March and July 2015 were designated into the control group. The hand hygiene compliance was compared between the two groups. From March to July 2016, alcohol-based hand disinfectants were used for disinfection on the glove surface during continuous blood sampling by nurses with gloves on their hands. Fifty samples were collected respectively after the gloves were used for 1, 2, 5, 10, and 15 continuous times for blood sampling. Then, the samples were sent to the bacteriology room for culture. Results All of the 250 samples were qualified, and the bacterial colonies on the surface of gloves were equal to 10 cfu/mL2 or lower. NoStaphylococcus aureus,Escherichiacoli or other pathogens were detected on the glove surface. However, after the gloves were continuously used for 15 times, the gloves of two nurses could not meet the research criteria again because of significant sweating. Conclusions In the process of continuous blood sampling, it is effective to use alcohol-based hand disinfectants to disinfect the surface of medical gloves, which can promote hand hygiene compliance to a certain extent. However, there is a certain limit on the times of usage for medical gloves.

          Release date:2017-03-27 11:42 Export PDF Favorites Scan
        • Comparative study among three methods on surface disinfection in Intensive Care Unit

          Objective To compare germicidal effect of three disinfectants acting on frequently-touched surfaces in Intensive Care Unit (ICU) at different time points after disinfection so as to put forward the reasonable disinfection method and interval before the next disinfection. Methods We wiped the four frequently-touched surfaces in ICU with disinfectant containing acidic electrolyzed oxidizing water (EOW) from the building system of hospital, disinfectant wipes, and 500 mg/L chlorine respectively. The culture samples were collected from the surfaces before wiping, and 10 minutes, 30 minutes, 1 hour, 2 hours and 4 hours after wiping respectively. The bacterial clearance rate and the qualified rate of bacterial colony counts on the surfaces were compared among the three different disinfectants at different time points after disinfection. Results The bacterial killing rate of three methods for disinfection of object surfaces decreased with the passing of time. The bacterial killing rate of EOW from the building system of hospital was lower than that of the other two methods at all five time points after disinfection (P< 0.05). The bacterial killing rate at hour four after disinfection using chlorine-containing disinfectant and disinfectant wipes was higher than 90.0%. The qualified rate of bacterial colony counts on the surfaces at 10 and 30 minutes after disinfection among the three groups was not significantly different (P>0.05). The qualified rate of bacterial colony counts on the surfaces disinfected by EOW from the building system of hospital was lower than that in the other two groups at the other three time points (P<0.05), and it was totally unqualified at hour four after disinfection. Conclusions The germicidal effect of EOW from the building system of hospital is inferior to chlorine disinfectant and disinfectant wipes. Moreover, the surface can be easily recontaminated after disinfection. It is suggested that EOW should be used in ICU every other hour. and the other two disinfection methods should be used every two hours.

          Release date:2017-03-27 11:42 Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品