1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "fracture" 1063 results
        • Characteristics of femoral neck fractures in young and middle-aged adults based on fracture mapping technology

          Objective To analyze the characteristics of femoral neck fractures in young and middle-aged adults by means of medical image analysis and fracture mapping technology to provide reference for fracture treatment. Methods A clinical data of 159 young and middle-aged patients with femoral neck fractures who were admitted between December 2018 and July 2019 was analyzed. Among them, 99 patients were male and 60 were female. The age ranged from 18 to 60 years, with an average age of 47.9 years. There were 77 cases of left femoral neck fractures and 82 cases of right sides. Based on preoperative X-ray film and CT, the fracture morphology was observed and classified according to the Garden classification standard and Pauwels’ angle, respectively. Mimics19.0 software was used to reconstruct the three-dimensional models of femoral neck fracture, measure the angle between the fracture plane and the sagittal plane of the human body, and observe whether there was any defect at the fracture end and its position on the fracture surface. Through reconstruction, virtual reduction, and image overlay, the fracture map was established to observe the fracture line and distribution. Results According to Garden classification standard, there were 6 cases of type Ⅰ, 61 cases of type Ⅱ, 54 cases of type Ⅲ, and 38 cases of type Ⅳ. According to the Pauwels’ angle, there were 12 cases of abduction type, 78 cases of intermediate type, and 69 cases of adduction type. The angle between fracture plane and sagittal plane of the human body ranged from –39° to +30°. Most of them were Garden type Ⅱ, Ⅳ and Pauwels intermediate type. The fracture blocks were mainly in the form of a triangle with a long base and mainly distributed below the femoral head and neck junction area. Twenty-six cases (16.35%) were complicated with bone defects, which were mostly found in Garden type Ⅲ, Ⅳ, and Pauwels intermediate type, located at the back of femoral neck and mostly involved 2-4 quadrants. The fracture map showed that the fracture line of the femoral neck was distributed annularly along the femoral head and neck junction. The fracture line was dense above the femoral neck and scattered below, involving the femoral calcar. Conclusion The proportion of displaced fractures (Garden type Ⅲ, Ⅳ) and unstable fractures (Pauwels intermediate type, adduction type) is high in femoral neck fractures in young and middle-aged adults, and comminuted fractures and bone defects further increase the difficulty of treatment. In clinical practice, it is necessary to choose treatment plan according to fracture characteristics. Anatomic reduction and effective fixation are the primary principles for the treatment of femoral neck fracture in young and middle-aged adults.

          Release date:2022-09-30 09:59 Export PDF Favorites Scan
        • Research progress of augmentation plate for femoral shaft nonunion after intramedullary nail fixation

          ObjectiveTo review the history, current situation, and progress of augmentation plate (AP) for femoral shaft nonunion after intramedullary nail fixation.MethodsThe results of the clinical studies about the AP in treatment of femoral shaft nonunion after intramedullary nail fixation in recent years were widely reviewed and analyzed.ResultsThe AP has been successfully applied to femoral shaft nonunion after intramedullary nail fixation since 1997. According to breakage of the previous nailing, AP is divided into two categories: AP with retaining the previous intramedullary nail and AP with exchanging intramedullary nail. AP is not only suitable for simple nonunion, but also for complex nonunion with severe deformity. Compared with exchanging intramedullary nail, lateral plate, and dual plate, AP has less surgical trauma, shorter healing time, higher healing rate, and faster returning to society. However, there are still some problems with the revision method, including difficulty in bicortical screw fixation, lack of anatomic plate suitable for femoral shaft nonunion, and lack of postoperative function and quality of life assessment.ConclusionCompared with other revision methods, AP could achieve higher fracture healing rate and better clinical prognosis for patients with femoral shaft nonunion. However, whether patients benefit from AP in terms of function and quality of life remain uncertain. Furthermore, high-quality randomized controlled clinical studies are needed to further confirm that AP are superior to the other revision fixations.

          Release date:2019-12-23 09:44 Export PDF Favorites Scan
        • TREATMENT OF INTERTROCHANTERIC FRACTURES WITH DYNAMIC HIP SCREW AND FEMORAL NECK ANTI-ROTATION SCREW

          Objective To investigate the appl ication of anti-rotation screw after dynamic hi p screw (DHS) in treatment of intertrochanteric fracture. Methods Between April 2006 and January 2010, 22 cases of intertrochanteric fractures underwent DHS fixation operation with an anti-rotation screw, including 15 males and 7 females with an average ageof 66.3 years (range, 54-83 years). Fractures were caused by sl ipping in 16 cases, traffic accident in 5 cases, and fall ing from height in 1 case. All cases showed closed fractures, including 13 cases in the left and 9 cases in the right. Eighteen cases were simple intertrochanteric fracture, 4 cases were intertrochanteric fractures compl icated with Colles fractures. According to Evans classification standard, there were 14 cases of type I, 6 cases of type II, 1 case of type III, and 1 case of type IV. The time from wound to operation was 3-7 days (mean, 4.5 days). Results The operation time ranged from 51-95 minutes (mean, 72 minutes). The intraoperative blood loss was 150-350 mL (mean, 270 mL). The hospital ization days were 12-35 days (mean, 16.8 days). Primary heal ing was observed in all cases. All cases were followed up 6-17 months (mean, 14 months). Union of fracture was observed at 12-16 weeks (mean, 13.6 weeks); no fracture or internal fixation loosening occurred. According to HUANG Gongyi’s standard of efficacy assessment, the results were excellent in 19 cases and good in 3 cases. Conclusion Appl ication of an anti-rotation screw can help to improve the strength of the DHS for the internal fixation of intertrochanteric fracture, especially the anti-rotation abil ity, which does not increase the operation time obviously.

          Release date:2016-08-31 05:42 Export PDF Favorites Scan
        • ABSTRACTSOBSERVATION OF THE HEMODYNAMICS OF BLOOD CIRCULATION OF FEMORAL HEADAFTER SUBCAPITAL FRACTURE BY E. C. T.

          fter fracture of femoral neck , the head is often encountered ayascular necrosis. It was not clearwhether the causes of the necrosis was due to injury of the artery or stagnation of venous return orboth. We had observed the hmeodynamics of the blood circulation of both fermoral head of both sides in 27 cases of subcapital fracture by E. C. T. (Emission Computerized Tomography). The resultsshowed that either old, fresh, or heal fractures showed stagnation of venous return. There wasoblite...

          Release date:2016-09-01 11:32 Export PDF Favorites Scan
        • The three-dimensional titanium miniplate rigid fixation in the treatment of fracture of maxilla

          The three-dimensional (3-D) Titanium miniplate system is one of the newest internal rigid fixation for the maxillo-mandibular surgery in recent years. The geometry of the plate assures a good stability in the three-dimensions of the fracture sits. Thirty patients suffering from maxillo-mandibular fractures had been operated on using the 3-D Titanium miniplates since 1991. The group of the patient included 16 cases of mandibular fractures, 8 cases of maxillary fractures and 6 cases of maxillo-mandibular fracture. All of the patient had very good result without any complication. The follow-up was 6 months to 3 years. The 3-D Titanium miniplate as an ideal easy to use, good resistance against torque forces and, compact forms of the miniplate were the some of the advantages. Clinical examples had been provided to illustrate the actual usage of the 3-D miniplate in the field of the surgical treatment for the maxillo-mandibular fracture. It is the author’s opinion that the internal rigid fixation by 3-D Titanium miniplates is a promising method of treating fractures of the maxilla and is to be better tolerated by the patients and surgeons.

          Release date:2016-09-01 11:08 Export PDF Favorites Scan
        • TREATMENTS OF TIBIAL PILON FRACTURES WITH A COMBINATION OF LIMITED INTERNAL FIXATION AND EXTERNAL FIXATION

          Objective To summarize the effect and complication of treatment for Pilon fracture using limited internal fixation combined with external fixation. Methods From April 1996 to June 2003, 20 patients with Pilon fracture were treated with limited internal fixation combined with external fixation as the treatment group and 22 patients with Pilon fracture with other methods as the control group. The X-ray films, clinical effect and complication were analyzed and compared between 2 groups. Results All cases were followed up for 8 to 26 months(15.2 months on average). According to Helfet’s criterion forclinical effect, the excellent and good rates were 75% in the treatment group and 72.7%in the control group, being no significant difference (Pgt;0.05). According to Burwell-charnley criterion for reduction, the X-ray film resultsshowed the excellent and good rates were 90% in the treatment group and 86.4% in the control group, being no significant difference (Pgt;0.05). But there was significant difference in complications between 2 groups (Plt;0.05). Conclusion Limited internal fixation combined with external fixation is better in resuming ankle joint function and remarkably reducing complication, especially in reducing soft tissue complication and collapse of bone joint; it is useful in the treatment of Pilon fracture.

          Release date:2016-09-01 09:30 Export PDF Favorites Scan
        • USE OF INTRAOPERATIVE RED BLOOD CELL SALVAGE IN THE ANTERIOR STABILE OPERATION OF SPINAL FRACTURE

          OBJECTIVE: To observe the clinical results in the anterior stabile operation of spinal fracture using red blood salvage. METHODS: Nineteen cases with spinal fracture were performed the anterior decompress operation. Blood cell salvage were used during operation. Other 20 cases were also reviewed as control group, who were received the same operation without blood cell salvage. RESULTS: In the 19 cases, average volume of autologous transfusion was 536 ml. Only two cases had homologous transfusion requirements. In the control group, all cases needed homologous transfusion (averaged 947 ml). CONCLUSION: In the anterior decompress operation, the intraoperative blood salvage is highly effective in reducing transfusion and also improves the security of operation

          Release date:2016-09-01 10:21 Export PDF Favorites Scan
        • EFFECT OF BONE MARROW MESENCHYMAL STEM CELLS-DERIVED EXTRACELLULAR MATRIX SCAFFOLD ON CHONDROGENIC DIFFERENTIATION OF MARROW CLOT AFTER MICROFRACTURE OF BONE MARROW STIMULATION IN VITRO

          Objective To evaluate the feasibility and validity of chondrogenic differentiation of marrow clot after microfracture of bone marrow stimulation combined with bone marrow mesenchymal stem cells (BMSCs)-derived extracellular matrix (ECM) scaffold in vitro. Methods BMSCs were obtained and isolated from 20 New Zealand white rabbits (5-6 months old). The 3rd passage cells were cultured and induced to osteoblasts, chondrocytes, and adipocytes in vitro, respectively. ECM scaffold was manufactured using the 3rd passage cells via a freeze-dying method. Microstructure was observed by scanning electron microscope (SEM). A full-thickness cartilage defect (6 mm in diameter) was established and 5 microholes (1 mm in diameter and 3 mm in depth) were created with a syringe needle in the trochlear groove of the femur of rabbits to get the marrow clots. Another 20 rabbits which were not punctured were randomly divided into groups A (n=10) and B (n=10): culture of the marrow clot alone (group A) and culture of the marrow clot with transforming growth factor β3 (TGF-β3) (group B). Twenty rabbits which were punctured were randomly divided into groups C (n=10) and D (n=10): culture of the ECM scaffold and marrow clot composite (group C) and culture of the ECM scaffold and marrow clot composite with TGF-β3 (group D). The cultured tissues were observed and evaluated by gross morphology, histology, immunohistochemistry, and biochemical composition at 1, 2, 4, and 8 weeks after culture. Results Cells were successfully induced into osteoblasts, chondrocytes, and adipocytes in vitro. Highly porous microstructure of the ECM scaffold was observed by SEM. The cultured tissue gradually reduced in size with time and disappeared at 8 weeks in group A. Soft and loose structure developed in group C during culturing. Chondroid tissue with smooth surface developed in groups B and D with time. The cultured tissue size of groups C and D were significantly larger than that of group B at 4 and 8 weeks (P lt; 0.05); group D was significantly larger than group C in size (P lt; 0.05). Few cells were seen, and no glycosaminoglycan (GAG) and collagen type II accumulated in groups A and C; many cartilage lacunas containing cells were observed and more GAG and collagen type II were synthesized in groups B and D. The contents of GAG and collagen increased gradually with time in groups B and D, especially in group D, and significant difference was found between groups B and D at 4 and 8 weeks (P lt; 0.05). Conclusion The BMSCs-derived ECM scaffold combined with the marrow clot after microfracture of bone marrow stimulation is effective in TGF-β3-induced chondrogenic differentiation in vitro.

          Release date:2016-08-31 04:07 Export PDF Favorites Scan
        • Comparison of effectiveness between plate and screw internal fixation in treatment of posterior malleolus fractures through posterolateral approach

          ObjectiveTo compare the effectiveness of posterior malleolus fractures treated by plate and screw internal fixation through posterolateral approach.MethodsThe clinical data of 95 patients with posterior malleolus fractures who were admitted between January 2016 and December 2019 and met the selection criteria were retrospectively analysed. They were divided into plate group (44 cases, treated with posterolateral plate internal fixation) and screw group (51 cases, treated with posterolateral screw internal fixation) according to different treatment methods. There was no significant difference in general data between the two groups of patients such as age, gender, cause of injury, side of injury, ankle fracture or injury classification, time from injury to operation, and percentage of posterior ankle fracture area to the distal tibia articular surface (P>0.05). The operation time, hospital stay, fracture healing time, and surgical complications were compared between the two groups. Imaging examinations (X-ray film, CT scan and reconstruction) were used to assess the reduction quality of ankle fracture, articular congruity, and re-displacement in ankle fracture. At last follow-up, the pain visual analogue scale (VAS) score was used to evaluate the patients’ pain, and the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score was used to evaluate ankle joint function.ResultsPatients in both groups were followed up 6-30 months, with an average of 18.2 months. The operation time of the plate group was significantly longer than that of the screw group (U=?2.040, P=0.041); there was no significant difference in hospital stay between the two groups (U=?1.068, P=0.285). Incision swelling occurred in 2 cases in the plate group, sural nerve injury in 3 cases, and traumatic arthritis in 2 cases during follow-up. In the screw group, there were 1, 2, and 2 cases, respectively. The incidence of complications in the two groups (15.9% vs. 9.8%) was not significantly different (P=0.372). All patients who underwent tibiofibular screw fixation underwent the removal of the tibiofibular screw before taking full weight bearing at 12 weeks after operation, and there was no screw fracture and retention. During the follow-up, there was no infection, re-displacement of fracture, delayed bone union or nonunion, and there was no significant difference in fracture healing time between the two groups (t=0.345, P=0.731). There was no significant difference between the two groups of reduction quality of ankle fracture and articular congruity evaluation results (P>0.05). At last follow-up, there was no significant difference in VAS score, AOFAS ankle-hindfoot score and evaluation grade between the two groups (P>0.05).ConclusionBoth the plate and screw internal fixation through posterolateral approach can achieve satisfied effectiveness in the treatment of posterior ankle fractures with maintenance of fracture reduction, and recovery of ankle joint function. The screw internal fixation has the advantages of minimal invasion and shorter operation time.

          Release date:2021-04-27 09:12 Export PDF Favorites Scan
        • EXPERT TIBIAL NAILS IN TREATMENT OF COMPLEX TIBIAL FRACTURES OF TYPE C

          Objective To study the cl inical effect of expert tibial nail (ETN) in the treatment of the complex tibial fractures of type C. Methods From May to October 2008, 10 cases of complex tibial fractures of type C were treated with unreamed ETN and closed reduction. There were 7 males and 3 females aging from 23 to 50 years with an average age of 39 years. Fracture was caused by traffic accident in 6 cases, by crush in 2 cases, and by fall ing from height in 2 cases. According to Association for the Study of Internal Fixation (AO/ASIF) classification, there were 2 cases of 42-C1 fractures, 4 cases of42-C2 fractures, and 4 cases of 42-C3 fractures; including 4 cases of closed fractures and 6 cases of open fractures (2 cases of Gustilo type I and 4 cases of Gustilo type II). Results The mean duration of surgery and blood loss were 75 minutes (range, 60-110 minutes) and 55 mL (range, 20-100 mL), respectively. All the incision healed by first intension without compl ication of infection. All cases were followed up for 12-17 months (average 14 months). X-ray films showed that no breakage of nail, iatrogenic fracture, l imb shortening, and angulation deformity occurred. All fractures healed after 3-8 months (average 4.2 months). At last follow-up according to Johner-Wruhs standard for the functional recovery, the results were excellent in 8 cases and good in 2 cases. Conclusion ETN has an angular stable locking system for intramedullary nails, which can enhance axial and transverse stabil ity for the treatment of complex tibial fractures of type C. It will provide firm fixation and minimal invasion.

          Release date:2016-08-31 05:48 Export PDF Favorites Scan
        107 pages Previous 1 2 3 ... 107 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品