Objective To compare heterotopic ossification between femoral head reconstruction and total hip arthroplasty(THA) in patients with ischemic necrosis of femoral head(INFH). Methods Between June 1994 and December 2004, the femoral heads were repaired in 1 005 patients with INFH,the total hip was replaced in 485 patients with INFH. The rate of heterotopic ossification was observed in 74 (Ficat Ⅲ to Ⅳ stages) of 1 005 patients and 80 of 485 patients given THA to compared the results of the two methods. Results These patients were followed up 2 to 10 years(6.5 years on average). The rates of heterotopic ossification were 5.4%(4/74) and 22.5%(18/80), respectively. There was statistically significant difference between two operative methods (Plt;0.01). Conclusion The rate of heterotopic ossification of femoral head reconstruction is lower than that of THA, so femoral head reconstruction is a better operative method for young patients and THA is suitable for old patients.
ObjectiveTo develop an artificial intelligence based three-dimensional (3D) preoperative planning system (AIHIP) for total hip arthroplasty (THA) and verify its accuracy by preliminary clinical application.MethodsThe CT image database consisting of manually segmented CT image series was built up to train the independently developed deep learning neural network. The deep learning neural network and preoperative planning module were assembled within a visual interactive interface—AIHIP. After that, 60 patients (60 hips) with unilateral primary THA between March 2017 and May 2020 were enrolled and divided into two groups. The AIHIP system was applied in the trial group (n=30) and the traditional acetate templating was applied in the control group (n=30). There was no significant difference in age, gender, operative side, and Association Research Circulation Osseous (ARCO) grading between the two groups (P>0.05). The coincidence rate, preoperative and postoperative leg length discrepancy, the difference of bilateral femoral offsets, the difference of bilateral combined offsets of two groups were compared to evaluate the accuracy and efficiency of the AIHIP system.ResultsThe preoperative plan by the AIHIP system was completely realized in 27 patients (90.0%) of the trial group and the acetate templating was completely realized in 17 patients (56.7%) of the control group for the cup, showing significant difference (P<0.05). The preoperative plan by the AIHIP system was completely realized in 25 patients (83.3%) of the trial group and the acetate templating was completely realized in 16 patients (53.3%) of the control group for the stem, showing significant difference (P<0.05). There was no significant difference in the difference of bilateral femoral offsets, the difference of bilateral combined offsets, and the leg length discrepancy between the two groups before operation (P>0.05). The difference of bilateral combined offsets at immediate after operation was significantly less in the trial group than in the control group (t=?2.070, P=0.044); but there was no significant difference in the difference of bilateral femoral offsets and the leg length discrepancy between the two groups (P>0.05).ConclusionCompared with the traditional 2D preoperative plan, the 3D preoperative plan by the AIHIP system is more accurate and detailed, especially in demonstrating the actual anatomical structures. In this study, the working flow of this artificial intelligent preoperative system was illustrated for the first time and preliminarily applied in THA. However, its potential clinical value needs to be discovered by advanced research.
【Abstract】 Objective To evaluate the flexibil ity of the treatment of osteoarthritis secondary to acetabular dysplasiaby total hip arthroplasty (THA) , in which the acetabular component is placed in the true acetabulum and femoral osteotomy is not performed. Methods From January 1999 to December 2005, 35 THA procedures were performed in 32 patients with 35 hips, including 6 males with 7 hips and 26 females with 28 hips, with the average age of 53 years (ranging from 28 years to 72 years). On the basis of Crowe classification, type I included 10 patients with 11 hips, type II included 14 patients with 15 hips, type III included 5 patients with 6 hips, and type IV included 3 patients with 3 hips. All patients experienced severe pain and dysfunction. In 19 cases, the leg length discrepancy was from 3 cm to 6 cm. The Harris score was 41.49 ± 10.13 before the operation. In all procedures, the soft tissue was released entirely and the acetabular component was placed in the true acetabulum, but femoral osteotomy was not performed. Results The average operation time of unilateral THA was 50 minutes. All patients were given transfusion from 2 U to 4 U. All incisions healed at the first stage. After the operation, the leg was lengthened 2-6 cm, and the two legs were equally long. The follow-up lasted for 12 to 60 months. The Harris score was 84.71 ± 9.34 after the operation, showing statistically significant differece (P lt; 0.05). According to cl inical outcomes and X-ray films, no dislocation, femoral fracture, femoral or sciatic nerve palsy was detected. Conclusion It is effective to use THA procedures for osteoarthritis secondary to acetabular dysplasia. If the soft tissue is released entirely, the leg will be lengthened 4-6 cm without nerve palsy.
Objective To investigate the relationship between the initial stabil ity and infected loosening of the total hip arthroplasty (THA) prosthesis. Methods From January 2000 to December 2008, 110 cases (110 hips) were treated with THA revision. Among them, 15 cases (15 hips) were confirmed infected loosening. There were 8 males and 7 females with anaverage age of 62 years (range 42-75 years). The infected signs were found from 6 months to 2 years after initial THA. All of them had Tsukayama type IV and late infection, including 6 cases of acetabular infected loosening (5 cases of one-stage and 1 case of two-stage acetabular revision), 7 cases of simple infected loosening of femoral prosthesis (4 cases of one-stage and 3 cases of twostage femoral prosthesis revision), and 2 cases of joint capsule infection and sinus without prosthesis loosening (debridement and continuous irrigation). Results All incisions healed by first intention. Fifteen patients were followed up for 12 to 36 months (average 24 months). In 13 cases of revision, postoperative X-ray films showed that femoral acetabular prostheses were in good position, and had no cl inical and imaging infective signs of loosening. In 2 cases of joint capsule infection, sinus recurred 6 months postoperation without hip joint pain, the function of weight-bearing and walking of hip joint was normal. Harris score increased from preoperative average of 42 to postoperative average of 85; the results were excellent in 4 cases, good in 7 cases, and fair in 4 cases. Conclusion The infection of THA may occur in the whole joint, half-joint or just in joint capsule. The initial stabil ity of the prosthesis would affect the long-term survival of the prothesis. If the prosthesis initial stabil ity is obtained, even if there are infective factors, infections would also be l imited.
ObjectiveTo investigate the efficacy of total hip arthroplasty (THA) assisted by the MAKO robotic arm via posterolateral approach.MethodsThe clinical data of 70 patients treated with THA via posterolateral approach between March 2017 and March 2019 who met the selection criteria were retrospectively analyzed. According to different treatment methods, the patients were divided into two groups, 35 were treated with MAKO robotic arm assisted THA (MAKO group) and 35 with traditional THA (THA group). There was no significant difference in gender, age, body mass index, disease duration, etiology, perioperative time, preoperative activity of daily living (ADL) scale index, American Society of Anesthesiologists (ASA) classification, walking ability, comorbidities, hemoglobin, and other general data between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, postoperative acetabular abduction and anteversion angles, postoperative length difference of bilateral lower limbs, and proportions of intraoperative blood transfusion, immediate postoperative loading, wound drainage time more than 2 days, and complications were recorded and compared between the two groups. According to the X-ray films at 6 months after operation, the reduction quality was judged. The forgotten joint score, Harris score, and proportions of independent walking and ADL index increased were used to evaluate the function recovery of patients.ResultsPatients in both groups were followed up 6-18 months, with an average of 8 months. There was no significant difference (P>0.05) between the two groups in operation time, intraoperative blood loss, hospital stay, acetabular abduction and anteversion angles, and length difference of both lower limbs at 6 months after operation. There was no significant difference in the proportions of intraoperative blood transfusion, immediate postoperative loading, and wound drainage time more than 2 days between the two group (P>0.05). X-ray reexamination at 6 months after operation showed that there was no significant difference in the reduction quality between the two groups (Z=4.191, P=0.123). Postoperative complications occurred in 7 patients (20.0%) in the MAKO group and 10 patients (28.6%) in the THA group, showing no significant difference in the incidence of complications between the two groups (χ2=2.121, P=0.224). Two patients (5.7%) in the MAKO group and 4 patients (11.4%) in the THA group underwent revision within 6 months, showing no significant difference in the revision rate between the two groups (χ2=0.729, P=0.673). At 3 and 6 months after operation, the proportions of independent walking and ADL index increased showed no significant difference between the two groups (P>0.05). Harris scores in both groups improved significantly when compared with preoperative scores (P<0.05); there was no significant difference in the forgotten joint scores and Harris scores between the two groups (P>0.05).ConclusionCompared with traditional THA, MAKO robotic arm assisted THA has longer operation time and more intraoperative blood loss, but it has the advantages of accurate positioning and simple operation, and there is no significant difference in short-term postoperative function recovery.
Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
ObjectiveTo evaluate the efficacy and safety of a loading high-dose tranexamic acid (TXA) followed by postoperative 5 doses in total hip arthroplasty (THA) by a randomized controlled trial.MethodsSeventy-two patients who underwent primary unilateral THA between December 2017 and March 2018 were randomly divided into two groups (36 patients in each group). A single dose of 20 mg/kg TXA was administered intravenously before 5-10 minutes of operation in group A; and a single dose of 40 mg/kg TXA was administered intravenously in group B at the same time point. All patients received 5 doses of 1 g TXA at 3, 6, 12, 18, and 24 hours after the first dose. There was no significant difference in gender, age, weight, height, body mass index, disease type, and combined medical diseases between the two groups (P>0.05). Total blood loss (TBL), lowest postoperative hemoglobin (Hb) level, fibrinolysis parameters [fibrin (ogen) degradation products (FDP), D-dimer], inflammatory factors [C-reaction protein (CRP), interleukin-6 (IL-6)], adverse events (thrombosis, pulmonary embolism) were recorded and compared between groups.ResultsThe TBL was significantly lower in group B than in group A (P<0.05). Furthermore, the lowest postoperative Hb level was significantly higher in group B than in group A (P<0.05). There was no significant difference in FDP and D-dimer before operation between the two groups (P>0.05). The levels of FDP and D-dimer were significantly lower in group B than in group A at 12 and 36 hours postoperatively (P<0.05). There was no significant difference in CRP and IL-6 before operation between the two groups (P>0.05). The levels of CRP and IL-6 were significant lower in group B than in group A at 12, 24, and 36 hours postoperatively (P<0.05). There was no significant difference at 14 days (P>0.05). There were 2 patients with intramuscular venous thrombosis in group A and 1 in group B after operation, and there was no significant difference in the incidence of embolic events (P>0.05). No deep venous thrombosis or pulmonary embolism occurred in all groups.ConclusionA loading high-dose TXA followed by postoperative 5 doses can further reduce the blood loss, provide additional fibrinolysis and inflammation control in THA, without increasing the risk of embolic events.
Objective To review the research on different surgical approaches and MRI evaluation of total hip arthroplasty (THA), to clarify the possible muscle damage caused by different approaches, and to help clinicians avoid intraoperative muscle damage and identify the causes of certain muscle-related complications after operation. MethodsThe research literature on different surgical approaches and MRI evaluation of THA at home and abroad was extensively reviewed to summarize the MRI performance of the posterior approach, modified direct lateral approach, direct anterior approach, and minimally invasive anterolateral approach (also called Orthopadische Chirurgie Munchen approach). Results The traditional posterior approach mainly damages the short external rotator muscle group and increases the incidence of postoperative dislocation; the piriformis-keeping posterior approach significantly improves the quality of the pyriformis tendon in the postoperative period, but it may lead to damage to the intrapelvic portion of the piriformis muscle. The modified direct lateral approach mainly damages the gluteus medius muscle, which increases the risk of postoperative claudication. The direct anterior approach mainly damages the vastus tensoris muscle and may result in damage to the short external rotator muscle group and the muscles around the incision. The minimally invasive anterolateral approach primarily damages the superior gluteal nerve, which subsequently leads to denervation of the broad fascial tensor fasciae latae, and this approach may also result in injury to the gluteus medius and gluteus minimus muscles. The muscle damage status significantly affects prognosis, and the minimally invasive approach is more suitable for elderly patients. ConclusionMRI can clarify the different types of muscle damage caused by different surgical approaches. Minimally invasive approaches can reduce muscle damage and improve postoperative function compared with traditional approaches, and can benefit elderly patients more, but due to the small field, forcing to expand the surgical field will lead to unintended muscle damage and reduce postoperative function.
Objective To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films. Methods The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods. Results The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods (t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 (P<0.001), 0.96 (P<0.001), and 0.96 (P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 (P<0.001), 0.93 (P<0.001), and 0.94 (P<0.001), respectively. Conclusion The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Objective To report a new offset parameter for total hip arthroplasty (THA)—greater trochanter offset (GTO), and analyze the effectiveness and feasibility of this parameter based on clinical data. Methods The 47 patients who met the selection criteria and admitted between January 2016 and May 2020 were selected as the research object. The global offset (GO) was used as the offset parameter in preoperative design. Firstly, the test-retest reliability and inter-rater reliability of GTO were analyzed based on pelvic X-ray films. The GTO reconstruction was defined as the difference between the operative side and the healthy side within ±5 mm, and 47 patients were divided into the reconstruction group and the non-reconstruction group. General data (age, gender, type and side of fracture, the interval between injury and operation), visual analogue scale (VAS) score, Harris score, gait score, and leg length discrepancy (LLD) were recorded and compared between two groups. Then, the GTO was used as the offset parameter in preoperative design of 21 patients (GTO group) admitted between June 2020 and December 2020. The pre- and post-operative clinical data were compared between GTO group and GO group to explore the feasibility of GTO for THA.Results Statistical analysis showed that GTO had good test-retest reliability (P<0.001) and inter-rater reliability (P<0.001). There was no significant difference in gender, age, type and side of fracture, the interval between injury and operation, preoperative VAS score, and LLD at 1 year after operation between the GTO reconstruction group and the non-reconstruction group, as well as between the GO and GTO groups (P>0.05). The Harris score and gait score at 1 year after operation, and difference of VAS score between pre- and post- operation in the reconstruction group and GTO group were significantly better than those in the non-reconstruction group and GO group, respectively (P<0.05). There were 23 cases (48.9%) in the GO group and 19 cases (90.5%) in the GTO group with GTO reconstruction, and the difference was significant (χ2=10.606, P=0.001). There were 25 cases (53.2%) in the GO group and 13 cases (61.9%) in the GTO group with GO reconstruction, and the difference was not significant (χ2=0.447, P=0.504). There were 34 cases (72.3%) in the GO group and 19 cases (90.5%) in the GTO group with LLD reconstruction, and the difference was not significant (χ2=2.777, P=0.096). Conclusion GTO has reliable test-retest reliability and inter-rater reliability. GTO as a parameter of preoperative offset reconstruction plan of THA can obtain good reconstruction of offset and limb length, and obtain a good effectiveness.