1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "lumbar spine" 15 results
        • Research on percutaneous puncture of thoracolumbar vertebral pedicle assisted by mixed reality technology based on multi-point registration algorithm

          Objective To evaluate the effectiveness of percutaneous puncture of thoracolumbar vertebral pedicle assisted by mixed reality technology based on multi-point registration algorithm. Methods The operator used two methods, namely MR-assisted puncture (a self-developed MR calibration method based on multi-point registration algorithm combined with MR head mounted equipment) and manual puncture, to perform percutaneous puncture of the thoracolumbar pedicle on the spinal prosthesis model. The distance between the first blind puncture point and the preset nail center point, and single registration and puncture time were compared among different puncture methods. Results Four operators completed a total of 48 MR-assisted punctures and 48 manual punctures. The deviation distance of MR-assisted puncture [(1.69±0.29) vs. (4.99±2.06) mm], registration and puncture time [(131.41±5.35) vs. (475.98±65.26) s] were all better than manual puncture (P<0.05). Conclusion The prosthetic model data shows that MR technology-assisted puncture based on multi-point registration algorithm can improve the accuracy and efficiency of percutaneous puncture of thoracolumbar vertebral pedicle compared to traditional manual puncture.

          Release date:2025-09-26 04:04 Export PDF Favorites Scan
        • EFFECTIVENESS COMPARISON BETWEEN PEDICLE SUBTRACTION OSTEOTOMY AND NON-OSTEOTOMYTECHNIQUES IN TREATMENT OF MEDIUM-TO-SEVERE KYPHOSCOLIOSIS

          Objective To evaluate the effectiveness of pedicle subtraction osteotomy (PSO) and non-osteotomy techniques in treatment of medium-to-severe kyphoscoliosis by retrospective studies. Methods Between January 2005 and January 2009, 99 patients with medium-to-severe kyphoscoliosis were treated by PSO (PSO group, n=46) and non-osteotomytechnique (non-osteotomy group, n=53) separately. There was no significant difference in sex, age, Cobb angle of scol iosis on coronal plane, and Cobb angle of kyphosis on saggital plane between 2 groups (P gt; 0.05). The operation time and blood loss were recorded; the Cobb angle of scol iosis on coronal plane and kyphosis on sagittal plane were measured at pre- and postoperation to caculate the rates of correction on both planes. Results The operation was successfully completed in all the patients. The operation time and blood loss of the patients in PSO group were significantly greater than those of the patients in non-osteotomy group (P lt; 0.05). All patients were followed up 12-56 months (mean, 22.4 months); no spinal cord injury occurred, and bone fusion was achieved at last follow-up. The Cobb angles of scol iosis and kyphosis at 2 weeks and last follow-up were significantly improved when compared with the preoperative angles in the patients of 2 groups (P lt; 0.05). There was no significant difference in Cobb angle of scol iosis and the rate of correction between 2 groups (P gt; 0.05), but the correction loss of PSO group was significantly smaller than that of non-osteotomy group (P lt; 0.05) at last follow-up. At 2 weeks and last follow-up, the Cobb angle of kyphosis, the rate of correction, and correction loss were significantly better in PSO group than in non-osteotomy group (P lt; 0.05). Conclusion There is no signifcant difference in scol iosis correction between PSO and non-osteotomy techniques.PSO can get better corrective effect in kyphosis correction than non-osteotomy technique, but the operation time and blood losswould increase greatly.

          Release date:2016-08-31 04:23 Export PDF Favorites Scan
        • SRS-Schwab grade Ⅳ osteotomy combined with satellite rod for thoracolumbar old osteoporotic fracture with severe kyphosis

          ObjectiveTo evaluate the effectiveness of SRS-Schwab grade Ⅳ osteotomy combined with satellite rod for thoracolumbar old osteoporotic fracture with severe kyphosis.MethodsBetween April 2013 and August 2016, 20 cases of thoracolumbar old osteoporotic fracture with severe kyphosis were treated with SRS-Schwab grade Ⅳ osteotomy combined with satellite rod. All the patients were females, aged 49-71 years (mean, 54.8 years). The disease duration was 6-28 months with an average of 14 months. The T value of bone density was –4.4 to –1.8 (mean, –2.8). The preoperative Cobb angle was (43.0±11.3)°. The vertebral compression fracture segment was T12 in 9 cases, L1 in 8 cases, and L2 in 3 cases. Preoperative spinal cord function was evaluated by Frankel classification; there were 5 cases of grade D and 15 cases of grade E. The operation time, intraoperative blood loss, and perioperative complication were recorded. The Cobb angle for kyphosis and sagittal vertical axis (SVA) were recorded beforeoperation, at 3 months after operation, and at last follow-up. Oswestry disability index (ODI) was used to evaluate the effectiveness before operation and at last follow-up, and the evaluation indicators included pain degree, daily life self-care ability, extracting, walking, sitting, standing, sleeping, social activities, and traveling.ResultsThe operation time was 180-314 minutes (mean, 226 minutes). The intraoperative blood loss was 390-1 800 mL (mean, 750 mL). All the incisions healed by first intension without incision infection. Twenty patients were followed up 24-52 months, with an average of 30.9 months. During the follow-up period, no significant complication such as correction loss, nail breakage, rod breakage, pseudoarthrosis formation, or proximal and distal junctional kyphosis occurred. All patients were able to walk upright after operation, and the pain relieved significantly at 6 months after operation. Bone fusion achieved at 12 months after operation. The Frankel grade of nerve function improved from grade D to grade E at last follow-up in 5 patients with nerve damage before operation. At last follow-up, the indicator scores of ODI significantly improved when compared with preoperative values (P<0.05). Cobb angle significantly improved at 3 months after operation and at last follow-up (P<0.05) when compared with preoperative one, but there was no significant difference in the Cobb angles between 3 months after operation and last follow-up (P>0.05). There was no significant difference in SVA between pre- and post-operation (P>0.05).ConclusionSRS-Schwab grade Ⅳ osteotomy combined with satellite rod for thoracolumbar old osteoporotic fracture with severe kyphosis is effective in achieving satisfactory clinical outcomes, as well as maintaining correction of kyphosis.

          Release date:2019-03-11 10:22 Export PDF Favorites Scan
        • Biomechanical Study of Lumbar Spine Under Different Vibration Conditions

          We observed the effect of vibration parameters on lumbar spine under different vibration conditions using finite element analysis method in our laboratory. In this study, the CT-images of L1-L5 segments were obtained. All images were used to develop 3D geometrical model using the Mimics10.01 (Materialise, Belgium). Then it was modified using Geomagic Studio12.0 (Raindrop Geomagic Inc. USA). Finite element (FE) mesh model was generated by Hypermesh11.0 (Altair Engineering, Inc. USA) and Abaqus. Abaqus was used to calculate the stress distribution of L1-L5 under different vibration conditions. It was found that in a vibration cycle, tensile stress was occurred on lumbar vertebra mainly. Stress distributed evenly and stress concentration occurred on the left rear side of the upper endplate. The stress had no obvious changes under different frequencies, but the stress was higher when amplitude was greater. In conclusion, frequency and amplitude parameters have little effect on the stress distribution in vertebra. The stress magnitude is positively correlated with the amplitude.

          Release date:2021-06-24 10:16 Export PDF Favorites Scan
        • COMBINED POSTERIOR AND ANTERIOR APPROACHES FOR RESECTION OF THORACOLUMBAR SPINAL HUGE DUMBBELL-SHAPED TUMOR

          ObjectiveTo investigate the surgical outcome of combined posterior and anterior approaches for the resection of thoracolumbar spinal canal huge dumbbell-shaped tumor. MethodsBetween January 2009 and March 2015, 12 patients with thoracolumbar spinal canal huge dumbbell-shaped tumor were treated by posterior approach and anterolateral approach through diaphragmatic crura and thoracoabdominal incision for complete resection. There were 9 males and 3 females, with an average age of 45 years (range, 30-65 years). The disease duration was 8-64 weeks (mean, 12.7 weeks). The tumor was located at T12, L1 in 6 cases, at L1, 2 in 5 cases, and at L2, 3 in 1 case. The tumor size ranged from 4.3 cm×4.0 cm×3.5 cm to 7.5 cm×6.3 cm×6.0 cm. According to tumor outside the spinal involvement scope and site and based on the typing of Eden, 5 cases were rated as type b, 2 cases as type d, 4 cases as type e, and 1 case as type f in the transverse direction; two segments were involved in 8 cases, and more than two segments in 4 cases. The degree of tumor excision, tumor recurrence, and the spine stability were observed during follow-up. The verbal rating scale (VRS) was used to evaluate pain improvement. ResultsThe average surgical time was 170 minutes (range, 150- 230 minutes); the average intraoperative blood loss was 350 mL (range, 270-600 mL). All incisions healed by first intention, and no thoracic cavity infection and other operation related complication occurred. Of 12 cases, 10 were histologically confirmed as schwannoma, and 2 as neurofibroma. The patients were followed up 6 months to 6 years (mean, 31 months). Neurological symptoms were significantly improved in all patients, without lower back soreness. The thoracolumbar X-ray film and MRI showed no tumor residue. No tumor recurrence, internal fixator loosening, scoliosis, and other complications were observed during follow-up. VRS at last follow-up was significantly improved to grade 0 (10 cases) or grade I (2 cases ) from preoperative grade I (2 cases), grade II (8 cases), and grade III (2 cases) (Z= —3.217, P=0.001). ConclusionCombined posterior approach and anterolateral approach through diaphragmatic crura and thoracoabdominal incision for complete resection of thoracolumbar spinal canal huge dumbbell-shaped tumor is feasible and safe, and can protect the stability of thoracolumbar spine and paraspinal muscle function. It can obtain satisfactory clinical result to use this method for treating the complex type of thoracolumbar spinal canal dumbbell-shaped tumor.

          Release date: Export PDF Favorites Scan
        • IMPROVEMENT OF TECHNIGUE IN RESTORATION OF STABILITY OF THORACO LUMBAL SPINE

          A new fixator for spine was designed to restore the stability of spine in improving the treatment of thoraco-lumbar dislocation. This instrument was composed of six nails, two longitudinal connecting rods and two transverse connecting rods. On the surface of the nails, there were furrows engraved, instead of screw thread. It fixed the spine through pedicle of vertebra from the posterior approach. The fixed vertebrae were limited between two vertebrae. From 1989 th 1995, twelve patients with fracture-dislocation of thoraco-lumbar spine were reduced with this instrument. After four years follow-up, it showed that the deformity was corrected and the spine firmly fixed. Compared with Dick’s screws, it had the following advantages such as simple manipulation, increased strergth of nails and minimal damage to tissue during operation.

          Release date:2016-09-01 11:08 Export PDF Favorites Scan
        • ANTEROLATERAL APPROACH FOR TREATMENT OF THORACOLUMBAR DISC PROTRUSION

          Objective To evaluate the effect of anterolateral approach in treating thoracolumbar disc protrusion. Methods From May 2004 to May 2008, 11 patients with thoracolumbar disc protrusion (T10-L3) underwent discectomy, autologous il iac bone graft, and internal fixation via anterolateral approach. There were 9 males and 2 females aged 26-57 years old (average 42.8 years old). The course of disease was 1 week-11 years (average 2.7 years). Nine patients showed the lower l imbs weakness, 8 had sensory disturbance, 6 presented with lumbodorsal pain, 5 had the lower l imb pain, 4 presentedwith sphincter muscle disturbance, 3 suffered from foot drop, and 5 had a history of lower back injury. X-ray, CT, and MRI test showed that 9 cases had the single-segmental protrusion, 2 cases had double-segmental protrusion, 2 cases were accompanied with ossification of the thoracic vertebra yellow l igament, 2 cases were combined with ossification of the vertebra posterior longitudinal l igament, and 1 was compl icated with Scheuermann disease. Preoperatively, the intervertebral height was (7.2 ± 1.3) mm and JOA score was 6.4 ± 2.8. Results The time of operation was 2.5-5.5 hours (average 3.5 hours); the blood loss during operation was 500-1 200 mL (average 750 mL). During operation, intraoperative pleural tear occurred in 1 patient, peritoneal tear in 1 patient, and dural laceration in 1 patient. Repairing was performed intraoperative and preventive suction drainage was used for 3-5 days. No postoperative hydropneumothorax and cerebrospinal fluid leakage occurred. All incisions healed by first intention. No postoperative compl ications of nerve system occurred. All the patients were followed up for 1-4 years (average 2.4 years). X-ray films showed that all the patients achieved bony fusion without the occurrence breakage and loosening of titanium plate and screw 6-9 months after operation. Three cases displayed subtle scol iosis (10-15°) without influence on spinal equil ibration. The intervertebral height increased to (12.3 ± 1.5) mm 2 weeks after operation, indicating there was a significant difference compared with preoperative value (P lt; 0.05). The intervertebral height 1 year after operation when the bony fusion was reached decreased to (7.5 ± 1.2) mm, indicating there was no significant difference compared to the preoperative value (P gt; 0.05). The JOA score increased to 7.6 ± 3.2 at 1 year after operation, indicating there was a significant difference compared with preoperative value (P lt; 0.05). The symptoms and signs of all the patients were improved to various degrees after operation. According to improvement rate evaluation system proposed by Hirabayashi t al., 4 cases were graded as excellent, 6 as good, 1 as fair, and the excellent and good rate was 90.9%. Conclusion Treating thoracolumbar disc protrusion via anterolateral approach is safe and effective.

          Release date:2016-09-01 09:08 Export PDF Favorites Scan
        • CLINICAL DIAGNOSIS AND TREATMENT OF MULTIPLE LEVEL THORACOLUMBAR SPINAL FRACTURES

          Objective To investigate the cl inical characteristics and methods of diagnosis and treatment of multiple level thoracolumbar spinal fractures. Methods From March 2002 to March 2006, 17 patients with 35 thoracolumbar spinal fractures were treated, 13 males and 4 females, aged 21-52 years old (36.4 on average), among whom there were 10 cases of traffic accident injury and 7 of high fall ing injury. One fracture was located at T2, 1 at T3, 1 at T10, 4 at T11, 6 at T12, 5 at L1, 3 at L2, 7 at L3, 5 at L4, and 2 at L15, with a total of 35 segments including 26 segments with unstable fractures and 9 segments with stable compression fractures. According to the Frankel grade, there was 1 case of grade A, 1 of grade B, 2 of grade C, 5 of grade D and 8 of grade E. The preoperative height of the anterior border of the vertebral body was (20.8 ± 3.8) mm and the preoperative kyphosis angle was (16.2 ± 3.4)°. All the unstable fractures were performed operation. Sixteen injured vertebras were treated with long-segment pedicle screw internal fixation; 8 were treated with short-segment pedicle screw internal fixation, and 2 were treated with anterior fusion and fixation. Five injured vertebras with stable compression fractures were not treated and 4 were treated with pedicle screw implantation. Results The operation time was 1.8-4.2 hours and the amount of blood loss was 300-900 mL. The incisions obtained heal ing by first intention after the operation. All 17 patients were followed up for 13-41 months (18 months on average), and radiological evaluation showed no failure of the internal fixation. After the operation, the Frankel scale assessment showed that 1 patient of grade A improved to grade B, 1 of grade B improved to grade C, 1 of grade C improved to grade D, 1 of grade C improved to grade E, 5 of grade D improved to grade E, and 8 of grade E had no improvement. At the final postoperative follow-up, the height of the anterior border of the vertebral body was (31.9 ± 3.2) mm and the kyphosis angle was (6.8 ± 3.7)°, which were significantly different from those of preoperation (P lt; 0.01). Conclusion The treatment of multiple level thoracolumbar spinal fractures should be individual ized according to the patients’ actual conditions in order to obtain decompression and stabil ity of spines.

          Release date:2016-09-01 09:19 Export PDF Favorites Scan
        • Effectiveness of robot-guided percutaneous fixation and decompression via small incision for advanced thoracolumbar metastases

          ObjectiveTo evaluate the effectiveness of robot-guided percutaneous fixation and decompression via small incision in treatment of advanced thoracolumbar metastases. Methods A clinical data of 57 patients with advanced thoracolumbar metastases admitted between June 2017 and January 2021 and met the selection criteria was retrospectively analyzed. Among them, 26 cases were treated with robot-guided percutaneous fixation and decompression via small incision (robot-guided group) and 31 cases with traditional open surgery (traditional group). There was no significant difference in gender, age, body mass index, lesion segment, primary tumor site, and preoperative Tokuhashi score, Tomita score, Spinal Instability Neoplastic Score (SINS), visual analogue scale (VAS) score, Oswestry disability index (ODI), Karnofsky score, and Frankel grading between groups (P>0.05). The operation time, hospital stays, hospital expenses, intraoperative blood loss, postoperative drainage volume, duration of intensive care unit (ICU) stay, blood transfusion, complications, and survival time were compared. The pedicle screw placement accuracy was evaluated according to the Gertzbein-Robbins grading by CT within 4 days after operation. The pain, function, and quality of life were evaluated by VAS score, ODI, Karnofsky score, and Frankel grading. Results During operation, 257 and 316 screws were implanted in the robot-guided group and the traditional group, respectively; and there was no significant difference in pedicle screw placement accuracy between groups (P>0.05). Compared with the traditional group, the operation time, hospital stays, duration of ICU stay were significantly shorter, and intraoperative blood loss and postoperative drainage volume were significantly lesser in the robot-guided group (P<0.05). There was no significant difference in hospital expenses, blood transfusion rate, and complications between groups (P>0.05). All patients were followed up 8-32 months (mean, 14 months). There was no significant difference in VAS scores between groups at 7 days after operation (P>0.05), but the robot-guided group was superior to the traditional group at 1 and 3 months after operation (P<0.05). The postoperative ODI change was significantly better in the robot-guided group than in the traditional group (P<0.05), and there was no significant difference in the postoperative Karnofsky score change and Frankel grading change when compared to the traditional group (P>0.05). Median overall survival time was 13 months [95%CI (10.858, 15.142) months] in the robot-guided group and 15 months [95%CI (13.349, 16.651) months] in the traditional group, with no significant difference between groups (χ2=0.561, P=0.454) . Conclusion Compared with traditional open surgery, the robot-guided percutaneous fixation and decompression via small incision can reduce operation time, hospital stays, intraoperative blood loss, blood transfusion, and complications in treatment of advanced thoracolumbar metastases.

          Release date:2023-09-07 04:22 Export PDF Favorites Scan
        • Reasons analysis on unplanned reoperation of degenerative lumbar spine diseases

          ObjectiveTo review the research on the reasons of unplanned reoperation (URP) for degenerative lumbar spine diseases, and to provide new ideas for improving the quality of surgery for degenerative lumbar spine diseases. Methods The literature about the URP of degenerative lumbar spine diseases at home and abroad in recent years was reviewed and analyzed. Results At present, the reasons for URP include surgical site infection (SSI), hematoma formation, cerebrospinal fluid leakage (CSFL), poor results of surgery, and implant complications. SSI and hematoma formation are the most common causes of URP, which happen in a short time after surgery; CSFL also occurs shortly after surgery but is relatively rare. Poor surgical results and implant complications occurred for a long time after surgery. Factors such as primary disease and surgical procedures have an important impact on the incidence of URP. ConclusionThe main reasons for URP are different in various periods after lumbar spine surgery. Interventions should be given to patients with high-risk URP, which thus can reduce the incidence of URP and improve the surgery quality and patients’ satisfaction.

          Release date:2022-01-12 11:00 Export PDF Favorites Scan
        2 pages Previous 1 2 Next