In order to investigate the histological and stereological change of the rapidly expanded skin tube, 15 Japanese Long Ear Rabbits were divided into 3 groups: (1) Rapid expansion group, injecting once a day for 7 days; (2) Routine expansion group, injecting every 3 days for 21 days and (3) Control group, no expander implanted. The results showed that: in the rapid expansion group, the thickness of the epidermis and dermis were both increased, fibroblast proliferation was active, a large amount of new capillaries was observed, the collagen fiber was in loose type, and the mitochondria and rough endoplasmic net of epithelial cell were increased. In the routine expansion group, similar changes were observed. The vascular density and volume fraction were significantly higher in rapid expansion group than those in the control group (P lt; 0.05). It was concluded that the rapid expansion of skin tube was feasible.
【Abstract】 Objective To explore the methods and appl ication value of surface shaded display (SSD) and multiplanarreconstruction (MPR) in the evaluation of acetabular morphology in patients with developmental dysplasia of the hip (DDH) before total hip arthroplasty (THA). Methods From October 2003 to November 2006, 17 patients (3 males and 14 females, aging from 35 years to 61 years) with osteoarthritis secondary to DDH were scanned with spiral CT preoperatively. According to the Crowe standard, 19 dysplasia hips were classified as type I in 4 hips, type II in 9 hips, type III in 6 hips. The obtained hip CT data were developed with SSD and MPR to observe spational position and bone stock of the acetabula. Results The dislocated extent was 25%-89% in these dysplasia hips according to the Crowe method and their sharp angles all exceeded 45°. Bone defect occurred to each of the acetabula, among which it was located in anterosuperior acetabulum in 5 hips, in superolateral acetabulum in 11 hips and in posterosuperior acetabulum in 3 hips. The hip images made with MPR showed that the minimum thickness of the medial wall of acetabula ranged from 2.0 mm to 10.9 mm. Among 15 unilateral dysplasia patients, the opening difference anddepth difference between the dysplasia acetabulum and the contralateral one ranged from 2.7 mm to 19.1 mm and from 2.3 mm to 13.1 mm, respectively. Conclusion SSD and MPR of spiral CT are effective methods in evaluating acetabular morphology preoperation and contribute to intraoperative acetabular reconstruction in patients with DDH performed THA.
ObjectiveTo study the effect of titanium particles on the proliferation, differentiation, and cytomorphology of osteoblasts, and to explore the possible internal relations and mechanism.
MethodsCalvarial osteoblasts were separated from 10 newborn Sprague Dawley rats by repeated enzyme digestion, and were cultured in vitro. The cells were identified by alkaline phosphatase (ALP) staining and alizarin red staining. The cells at passage 3 were cultured with titanium particles culture medium at concentrations of 0.01, 0.05, 0.1, 0.5, and 1 mg/mL (0.01, 0.05, 0.1, 0.5, and 1 mg/mL groups). The absorbance (A) values were detected by cell counting kit 8 at 7 days after cultured to compare the effect of titanium particles at different concentrations on proliferation, and median lethal concentration was screened out. The expression of collagen type I was detected by ELISA to observe the effect of titanium particles on differentiation. The osteoblasts co-cultured with titanium particles of median lethal concentration (experimental group) for 7 days, and double fluorescence staining with FITC-phalloidine and propidium iodide was performed. The cytomorphology variation of osteoblasts after swallowing titanium particles was observed under laser scanning confocal microscope. The osteoblasts at passage 3 cultured with culture medium without titanium particles served as control group.
ResultsThe cultured cells were identified as osteoblasts by ALP staining and alizarin red staining. Different concentrations of titanium particles could inhibit osteoblasts proliferation and differentiation in varying degrees, showing significant difference when compared with the control group at 7 days after culture (P<0.05). The cell proliferation and differentiation were decreased with increased titanium particles concentration; significant differences were found between the other groups (P<0.05) except 0.01 and 0.05 mg/mL groups (P>0.05). The median lethal concentration of titanium particles was 0.5 mg/mL. Laser scanning confocal microscope showed cellular shrinking, microfilaments distortion, pseudopodia contraction of osteoblasts that swallowed titanium particles in the experimental group.
ConclusionTitanium particles can inhibit proliferation and differentiation of osteoblasts. The effect may be related to variation of cytomorphology after swallowing titanium particles.
Objective To explore the related factors of femoral stem anteversion (FSA) after total hip arthroplasty (THA), so as to provide reference for clinical design of FSA before operation and reduce the risk of hip dislocation after arthroplasty. Methods Ninty-three patients (103 hips) who underwent THA between October 2021 and September 2022 and met the selection criteria were selected as the study subjects. Among them, there were 48 males and 45 females with an average age of 58.5 years (range, 25-88 years). Body mass index was 18.00-37.84 kg/m2, with an average of 24.92 kg/m2. There were 51 cases (57 hips) of osteonecrosis of femoral head, 35 cases (39 hips) of hip osteoarthritis, and 7 cases (7 hips) of congenital hip dysplasia. Based on CT images, the following indicators were measured: preoperative femoral neck anteversion (FNA), preoperative femoral rotation angle (FRA), preoperative acetabular anteversion (AA), and preoperative combined anteversion (CA; the sum of preoperative FNA and AA); postoperative FSA and the change in femoral anteversion angle (the difference between postoperative FSA and preoperative FNA). Based on preoperative X-ray films, the following indicators were measured: femoral cortical thickness index (CTI) and canal flare index (CFI), the proximal femoral medullary cavity was classified according to Noble classification (champagne cup type, normal type, chimney type), neck-shaft angle (NSA), and femoral offset (FO). Pearson correlation analysis, one-way ANOVA, and Point-biserial correlation analysis were used to investigate the correlation between postoperative FSA, postoperative change in femoral anteversion angle, and patient diagnosis, proximal femoral medullary cavity anatomy type, gender, age, as well as preoperative FNA, FRA, AA, CA, NSA, FO, CTI, and CFI. FSA was used as the dependent variable and the independent variables that may be related to it were included for multiple linear regression analysis. Results Based on CT image measurement, preoperative FNA was (15.96±10.01)°, FRA (3.36±10.87)°, AA (12.94±8.83)°, CA (28.9±12.6)°, postoperative FSA (16.18±11.01)°, and postoperative change in femoral anteversion angle was (0.22±9.98)°. Based on preoperative X-ray films measurements, the CTI was 0.586±0.081; the CFI was 4.135±1.125, with 23 hips classified as champagne cup type, 68 hips as normal type, and 12 hips as chimney type in the proximal femoral medullary cavity anatomy; NSA was (132.87±7.83)°; FO was (40.53±10.11) mm. There was no significant difference between preoperative FNA and postoperative FSA (t=?0.227, P=0.821). Pearson correlation analysis showed that postoperative FSA was positively correlated with preoperative FNA, preoperative CA, postoperative change in femoral anteversion angle, and age (P<0.05), while negatively correlated with preoperative FRA (P<0.05). The postoperative change in femoral anteversion angle were positively correlated with preoperative FRA and postoperative FSA (P<0.05), and negatively correlated with preoperative CA and FNA (P<0.05). One-way ANOVA analysis showed that the above two indicators were not correlated with diagnosis and the proximal femoral medullary cavity anatomy type (P>0.05). Multiple linear regression analysis showed a linear correlation between FSA and FNA, CA, age, and FRA (F=10.998, P<0.001), and the best fit model was FSA=0.48×FNA–2.551. Conclusion The factors related to FSA after THA include patient’s age, preoperative FNA, CA, FRA and postoperative femoral anteversion, of which preoperative FNA is the most closely related. When designing a surgical plan before surgery, attention should be paid to the patient’s preoperative FNA, and if necessary, CT around the hip joint should be scanned to gain a detailed understanding of the proximal femoral anatomical structure.
Objective To explore the morphological characteristics of the postero-superior protuberance of the calcaneus and to explore its relationship with Haglund malformation. MethodsAnkle lateral X-ray films of 391 hospitalized patients between May 2021 and June 2024 were retrospectively collected. The morphological parameters of the postero-superior protuberance of the calcaneus were measured, including the length of the base, the height of the base, and the tip angle of the postero-superior protuberance of the calcaneus, and the morphological types were classified according to the above parameters, including the peak type, the hill type, and the flat type. The related parameters of Haglund malformation were measured, including Fowler-Philipp angle (FPA), calcaneal pitch angle (CPA), parallel pitch line (PPL), Chauveaux-Liet angle (CLA), and X/Y ratio (total calcaneal length/length of greater tuberosity of calcaneus). The differences of the morphological parameters of the postero-superior protuberance of the calcaneus and the related indicators of Haglund deformity among the three types and between the males and the females were compared and analyzed, and the differences of the positive numbers of the related indicators of Haglund deformity among the three types were compared. ResultsAccording to the morphological parameters of the postero-superior protuberance of the calcaneus, there were 64 cases of peak type, 245 cases of hill type, and 82 cases of flat type. There was no significant difference in the length of the base of the postero-superior protuberance of the calcaneus, CPA, CLA, and X/Y ratio among the three types (P>0.05). Among the three types, the peak type had the largest FPA and the flat type had the smallest (P<0.05); the peak type had the smallest tip angle of the postero-superior protuberance of the calcaneus and the flat type had the largest (P<0.05); the positive rate of PPL in the hill type was significantly higher than that in the peak type and flat type (P<0.05); the height of the base of the postero-superior protuberance of the calcaneus in the flat type was the smallest (P<0.05). FPA, CPA, CLA, PPL, and X/Y ratio were positive in 2, 42, 172, 142, and 77 patients, respectively. There was no significant difference in the number of positive Haglund deformity indicators among the three types (P>0.05). There was no significant difference between male and female patients in the tip angle of the postero-superior protuberance of the calcaneus, FPA, the positive rate of PPL, and X/Y ratio (P>0.05). The length and the height of the base of the postero-superior protuberance of the calcaneus, CPA, and CLA in male patients were significantly higher than those in female patients (P<0.05). ConclusionThe postero-superior protuberance of the calcaneus can be divided into three types: the peak type, the hill type, and the flat type. The peak type is more likely to suffer from Haglund deformity, and the males are more likely to suffer from Haglund deformity than the females.
In this work, a new method of heart sound signal preprocessing is presented. First, the heart sound signals are decomposed by using multilayer wavelet transform. And then double parameters as thresholds are used in processing each layer after decomposition for denoising. Next, reconstruction of heart sound signals could be done after processing last layer. Four methods, i.e. wavelet transform, Hilbert-Huang transform (HHT), mathematical morphology, and normalized average Shannon energy, were used to extract the envelop of the heart sound signals respectively after reconstruction of heart sounds. All methods were improved in this study. We finally in our study chose 30 cases of raw heart sound signals, which were selected randomly from a database comed from The Clinical Medicine Institute of Montreal, and processed them by using the improved methods. The results were satisfactory. It showed that the extracted envelope with the original signal has a high degree of matching, whether it is a low frequency portion or high frequency portion. Most of all information of heart sound has been maintained in the envelope.
ObjectiveTo investigate the morphology of coronal femoral intertrochanteric fracture and its effect on reduction and internal fixation.MethodsThe clinical and imaging data of 46 patients with femoral intertrochanteric fracture who met the selection criteria between August 2017 and October 2018 were reviewed. There were 15 males and 31 females; the age ranged from 62 to 91 years, with an average of 72.8 years. The causes of injury included walking falls in 35 cases, falling out of bed in 4 cases, and traffic accidents in 7 cases. The AO/Orthopaedic Trauma Association classification was type 31-A1 in 11 cases and type 31-A2 in 35 cases. All patients underwent closed reduction and internal fixation with intramedullary nails. During the operation, fracture reduction and fixation were performed according to the preoperative evaluation results. According to the patients’ preoperative X-ray film and CT three-dimensional reconstruction images, the direction of the coronal fracture line of the femoral intertrochanter and the morphological characteristics of the fracture block were observed; and the coronal fracture discrimination analysis was carried out for the fractures of different AO/OTA types. The percentages of coronal femoral intertrochanteric fractures diagnosed by preoperative X-ray film and CT three-dimensional reconstruction were calculated and statistically analyzed. The fracture reduction, the position of internal fixation [measurement of tip-apex distance (TAD)]. and the reliability of internal fixation were observed after operation.ResultsX-ray film was not easy to identify coronary fracture, and the coronal fracture line and the shape of the fracture piece weree clearly visible in CT three-dimensional reconstruction images. The morphological characteristics of the coronary fracture block: in AO/OTA 31-A1 type, the fracture line extended obliquely backward from the anterior tip of the large rotor, above the small rotor with or without small rotor fracture; in AO/OTA 31-A2 type, fracture line extended obliquely backward from the anterior tip of the large rotor to below the small rotor. Thirteen cases (28.3%) of coronal fractures were found on preoperative X-ray films, and 35 cases (76.1%) were found by CT three-dimensional reconstruction, showing significant difference (χ2=21.083, P=0.000). In AO/OTA 31-A1 type patients, the proportion of coronal fractures found by X-ray film and CT three-dimensional reconstruction was 18.2% (2/11) and 54.5% (6/11), respectively, and that in AO/OTA 31-A2 type patients was 31.4% (11/35) and 82.9% (29/35), respectively, showing significant differences (χ2=3.143, P=0.000; χ2=20.902, P=0.000). Among the 35 patients with coronal fractures, 6 cases (17.1%) of AO/OTA 31-A1 type, 29 cases (82.9%) of AO/OTA 31-A2 type. The operation time of the patient was 80-112 minutes, with an average of 95 minutes; the intraoperative blood loss was 180-450 mL, with an average of 360 mL. There was no complication such as infection, falling pneumonia, and deep vein thrombosis of the lower extremities. At 3 days after operation, the internal fixators were all in the proper position. The TAD was 0.9-1.8 cm, with an average of 1.4 cm. All patients were followed up 14-18 months, with an average of 16 months. All the fractures healed osseously, and there was no complication such as nonunion and loosening of internal fixation.ConclusionCT three-dimensional reconstruction can better identify coronal femoral intertrochanteric fractures than X-ray films, and accurately recognize and analyze the incidence and morphological characteristics of coronal fractures, which can help formulate more effective surgical strategies to promote patient recovery.
ObjectiveTo study a deep learning-based dual-modality fundus camera which was used to study retinal blood oxygen saturation and vascular morphology changes in eyes with branch retinal vein occlusion (BRVO). MethodsA prospective study. From May to October 2020, 31 patients (31 eyes) of BRVO (BRVO group) and 20 healthy volunteers (20 eyes) with matched gender and age (control group) were included in the study. Among 31 patients (31 eyes) in BRVO group, 20 patients (20 eyes) received one intravitreal injection of anti-vascular endothelial growth factor drugs before, and 11 patients (11 eyes) did not receive any treatment. They were divided into treatment group and untreated group accordingly. Retinal images were collected with a dual-modality fundus camera; arterial and vein segments were segmented in the macular region of interest (MROI) using deep learning; the optical density ratio was used to calculate retinal blood oxygen saturation (SO2) on the affected and non-involved sides of the eyes in the control group and patients in the BRVO group, and calculated the diameter, curvature, fractal dimension and density of arteriovenous in MROI. Quantitative data were compared between groups using one-way analysis of variance. ResultsThere was a statistically significant difference in arterial SO2 (SO2-A) in the MROI between the affected eyes, the fellow eyes in the BRVO group and the control group (F=4.925, P<0.001), but there was no difference in the venous SO2 (SO2-V) (F=0.607, P=0.178). Compared with the control group, the SO2-A in the MROI of the affected side and the non-involved side of the untreated group was increased, and the difference was statistically significant (F=4.925, P=0.012); there was no significant difference in SO2-V (F=0.607, P=0.550). There was no significant difference in SO2-A and SO2-V in the MROI between the affected side, the non-involved side in the treatment group and the control group (F=0.159, 1.701; P=0.854, 0.197). There was no significant difference in SO2-A and SO2-V in MROI between the affected side of the treatment group, the untreated group and the control group (F=2.553, 0.265; P=0.088, 0.546). The ophthalmic artery diameter, arterial curvature, arterial fractal dimension, vein fractal dimension, arterial density, and vein density were compared in the untreated group, the treatment group, and the control group, and the differences were statistically significant (F=3.527, 3.322, 7.251, 26.128, 4.782, 5.612; P=0.047, 0.044, 0.002, <0.001, 0.013, 0.006); there was no significant difference in vein diameter and vein curvature (F=2.132, 1.199; P=0.143, 0.321). ConclusionArterial SO2 in BRVO patients is higher than that in healthy eyes, it decreases after anti-anti-vascular endothelial growth factor drugs treatment, SO2-V is unchanged.
ObjectiveTo explore the effect of false acetabulum on the development and anatomical morphology of proximal femur in Crowe type Ⅳ developmental dysplasia of the hip (DDH), providing a theoretical basis for the development of femoral reconstruction strategy and prosthesis selection for total hip arthroplasty. Methods The medical records of 47 patients (54 hips) with Crowe type Ⅳ DDH between February 2008 and March 2020 were retrospectively analyzed, of which 21 patients (26 hips) were Crowe type Ⅳa (type Ⅳa group) and 26 patients (28 hips) were Crowe type Ⅳb (type Ⅳb group). There was no significant difference in general data such as gender, age, height, weight, body mass index, and side between the two groups (P>0.05), which were comparable. The height of femoral head dislocation, the height of pelvis, and the proportion of dislocation were measured based on preoperative anteroposterior pelvic X-ray film. Based on the preoperative femoral CT scan data, the anatomical parameters of the femur and femoral medullary cavity were measured after three-dimensional reconstruction using Mimics19.0 software to calculate the canal fare index; and the femoral medullary cavity parameters were matched with the modular S-ROM prosthesis parameters. ResultsThe results of X-ray film measurement showed that the height of femoral head dislocation and the proportion of dislocation in type Ⅳa group were significantly higher than those in type Ⅳb group (P<0.05). There was no significant difference in the height of pelvis between the two groups (P>0.05). The results of CT three-dimensional reconstruction measurements showed that compared with the type Ⅳb group, the type Ⅳa group had less isthmus height, smaller femoral head, shorter femoral neck, narrower neck-shaft angle, increased anteversion angle, and higher greater trochanter, and the differences were significant (P<0.05). There was no significant difference in the height of femoral head, femoral offset, and height difference between greater trochanter and femoral head between the two groups (P>0.05). There was no significant difference in the mediolateral width (ML), anteroposterior width (AP), and diameter of the isthmus (Ci level) and the AP of the medullary cavity in the plane 40 mm distal to the most prominent point on the medial side of the lesser trochanter (C–40 level) (P>0.05), and the size of medullary cavity was significantly smaller in type Ⅳa group than in type Ⅳb group at the other levels (P<0.05). Compared with the type Ⅳb group, the difference between the outer diameter of the prosthetic sleeve and the diameter of the medullary cavity fitting circle in the plane where the center of femoral head rotation was located from the medial most prominent point of the lesser trochanter (C0 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). The difference between the longest diameter of the prosthetic sleeve triangle and the ML of the medullary cavity in the plane 10 mm proximal to the most prominent point on the medial side of the lesser trochanter (C+10 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). ConclusionFalse acetabulum has a significant impact on the morphology of the proximal femur and medullary cavity in patients with Crowe type Ⅳ DDH, and the application of three-dimensional reconstruction technique can accurately evaluate the femoral morphology and guide the selection of femoral prosthesis.
ObjectiveTo compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS). Methods A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the “gold standard”. The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed. Results The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the “gold standard”, the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939). Conclusion Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.