Objective To compare the efficacy and safety of dynamic hip screw (DHS) + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults. Methods PubMed, Web of Science, Cochrane Library, China National Knowledge Infrastructure, SinoMed, Wanfang, and Chongqing VIP database were searched for the literature related to the comparison between DHS + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults from the establishment of databases to 2022. RevMan 5.3 software was used for meta-analysis. Results Finally, 25 clinical studies were included, including 8 randomized controlled trials and 17 observational studies, 5 in English and 20 in Chinese. There were a total of 2099 patients, including 989 in the DHS + anti-rotation screw group and 1110 in the cannulated screw group. The meta-analysis results showed that the incidence of bone nonunion [odds ratio (OR)=0.29, 95% confidence interval (CI) (0.17, 0.48)], incidence of femoral head necrosis [OR=0.48, 95% CI (0.27, 0.88)], failure rate of internal fixation [OR=0.28, 95% CI (0.15, 0.51)] in the DHS + anti-rotation screw group were lower than those in the cannulated screw group (P<0.05). The surgical duration [mean difference (MD)=9.91, 95% CI (6.78, 13.05)], incision length [MD=1.25, 95% CI (0.15, 2.35)], and Harris score [MD=6.77, 95% CI (4.66, 8.88)] in the DHS + anti-rotation screw group were higher than those in the cannulated screw group (P<0.05). There was no statistically significant difference in intraoperative bleeding volume, Visual Analogue Scale score, hospital stay, and fracture healing time between the two groups (P>0.05). The incidence of bone nonunion in the DHS + anti-rotation screw group after Pauwels type Ⅲ fracture [OR=0.16, 95% CI (0.05, 0.50)] was lower than that in the cannulated screw group (P<0.05), and there was no statistically significant difference in the incidence of femoral head necrosis between the two groups (P>0.05). Conclusions For femoral neck fracture in adults, DHS + anti-rotation screw can reduce the incidence of bone nonunion, femoral head necrosis, and internal fixation failure compared with cannulated screw alone, and has a higher Harris score, but the surgical duration and incision are longer. Overall, DHS + anti-rotation screw are better at reducing the incidence of complications than cannulated screws alone.
Objective?To introduce the concept and clinical applications of rotational alignment of the femoral prosthesis in total knee arthroplasty (TKA) so as to avoide the postoperative complications caused by rotational alignment.?Methods?The clinical and experimental research literature about rotational alignment of the femoral prosthesis in TKA was extensively reviewed and analyzed.?Results?Femoral prosthesis malrotation can lead to flexion gap unbalanced and undesirable patellar track. Rotation alignment of the femoral prosthesis is defined with radiological and computer assisted technique at pre- and post-operation, which can make the rotation alignment of the femoral prosthesis and the function of the knee favorable.?Conclusion?In recent years, many surgical skills and new techniques of defining the rotational alignment are developed, and good clinical results are achieved.
Objective To evaluate effectiveness of proximal femur bionic nail (PFBN) in treatment of intertrochanteric fractures in the elderly compared to the proximal femoral nail antirotation (PFNA). Methods A retrospective analysis was made on 48 geriatric patients with intertrochanteric fractures, who met the selection criteria and were admitted between January 2020 and December 2022. Among them, 24 cases were treated with PFBN fixation after fracture reduction (PFBN group), and 24 cases were treated with PFNA fixation (PFNA group). There was no significant difference in baseline data such as age, gender, cause of injury, side and type of fracture, time from injury to operation, and preoperative mobility score, American Society of Anesthesiologists (ASA) score, Alzheimer’s disease degree scoring, self-care ability score, osteoporosis degree (T value), and combined medical diseases between the two groups (P>0.05). The operation time, intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, occurrence of complications, weight-bearing time after operation, and postoperative visual analogue scale (VAS) score, walking ability score, mobility score, self-care ability score were recorded and compared between the two groups. And the radiographic assessment of fracture reduction quality and postoperative stability, and fracture healing time were recorded. ResultsThe operations in both groups were successfully completed. All patients were followed up 6-15 months with an average time of 9.8 months in PFBN group and 9.6 months in PFNA group. The operation time was significantly longer in PFBN group than in PFNA group (P<0.05), but there was no significant difference in intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, change in activity ability score, and change in self-care ability score between the two groups (P>0.05). The weight-bearing time after operation was significantly shorter in PFBN group than in PFNA group (P<0.05), and the postoperative VAS score and walking ability score were significantly better in PFBN group than in PFNA group (P<0.05). Radiographic assessment showed no significant difference in fracture reduction scores and postoperative stability scores between the two groups (P>0.05). All fractures healed and there was no significant difference in fracture healing time between the two groups (P>0.05). The incidence of complications was significantly lower in PFBN group (16.7%, 4/24) than in PFNA group (45.8%, 11/24) (P<0.05). ConclusionCompared with PFNA, PFBN in the treatment of elderly intertrochanteric fractures can effectively relieve postoperative pain, shorten bed time, reduce the risk of complications, and facilitate the recovery of patients’ hip joint function and walking ability.
The present paper is aimed to explore the origins of Proteus mirabilis (PM) whorl swarming growth phenomenon. The whorl swarming growth phenomenon of PM was observed by changed bacterial culture inoculation time, humidity, vaccination practices, cultured flat placement, magnetic field, pH and other factors. Bacterial ring spiral direction of rotation is counterclockwise and the volatile growth process of PM was whorl swarming growth phenomenon. Spiro fluctuation phenomenon was of high frequency in the sealing tanks by cultured anytime inoculation, wherever inoculation technique applied or not, the presence or absence of the magnetic field, and wherever the dish position was. The experimental results showed that the whorl swarming growth phenomenon of PM requires specific pH environment, in which the facts may be relative to its genetic characteristics and the Earth's rotation.
ObjectiveTo investigate the effectiveness of proximal femoral nail anti-rotation (PFNA) and cerclage fixation for complicated femoral subtrochanteric fractures.MethodsA clinical data of 74 patients with complicated femoral subtrochanteric fractures, who were admitted between March 2016 and March 2019 and met the criteria, was retrospectively analyzed. Among them, 39 patients were treated with limited open reduction and PFNA combined with cerclage fixation (observation group) and 35 patients were treated with closed reduction and PFNA fixation (control group). There was no significant difference in gender, age, cause of injury, side and type of fracture, and the time from injury to operation (P>0.05). The ratio of postoperative hemoglobin (1, 3, and 5 days) to the preoperative hemoglobin, the operation time, the first weight-bearing time after operation, and the hospital stay were recorded. X-ray films were taken to observe fracture healing in the two groups and bone resorption around the cerclage in the observation group, and the fracture healing time was recorded. Hip function was evaluated by Harris scoring. ResultsThe operation time of the observation group was significantly longer than that of the control group (P<0.05), but the first weight-bearing time and hospital stay were significantly shorter (P<0.05). All patients were followed up 12 months. There was no significant difference in the ratios of post- to pre-operative hemoglobin (1, 3, and 5 days) between the two groups (P>0.05). X-ray film reexamination showed that the fractures of the two groups healed smoothly, and the fracture healing time of the observation group was significantly shorter than that of the control group (t=?12.989, P=0.000). No bone resorption around the cerclage occurred in the observation group. The Harris scores of the observation group were better than those of the control group at 7 days and 1, 2, and 3 months after operation (P<0.05), and there was no significant difference between the two groups at 6 months after operation (t=1.329, P=0.180).ConclusionCompared with PFNA fixation, PFNA combined with cerclage fixation for the complicated femoral subtrochanteric fractures has a shorter operation time, and can obtain immediate stability after fixation, which can meet the needs of patients for early functional exercise.
ObjectiveTo investigate the short-term effectiveness of derotational distal femoral osteotomy (DDFO) combined with medial patellofemoral ligament (MPFL) reconstruction in treatment of recurrent patellar dislocation with excessive femoral anteversion angle (FAA≥30°). MethodsBetween June 2017 and August 2019, 17 patients with recurrent patellar dislocation with FAA≥30° were treated with DDFO and MPFL reconstruction. There were 5 males and 12 females, aged 14-22 years, with an average of 17.7 years. The patella dislocated for 2 to 8 times (mean, 3.6 times). The disease duration was 2-7 years (mean, 4.6 years). The patellar apprehension tests were positive. Preoperative pain visual analogue scale (VAS) score, Lysholm score, Tegner score, and Kujala score were 4.2±1.1, 47.8±8.1, 3.6±1.1, and 56.8±5.7, respectively. FAA, mechanical lateral distal femoral angle (mLDFA), lateral patella displacement (LPD), tibial tuberosity-trochlear groove distance (TT-TG) were (34.9±3.4)°, (85.8±3.0)°, (13.7±3.8) mm, and (23.1±2.1) mm, respectively. ResultsAll incisions healed by first intention, and there was no complications such as knee stiffness, infection, and re-dislocation of the patella. All patients were followed up 13-25 months, with an average of 17.7 months. The imaging review showed that 1 case of osteotomy did not union, and achieved satisfactory results after the secondary revision and strengthening fixation; the osteotomies of other patients healed completely after 3 to 4 months of operation. The patellar apprehension tests were negative. At last follow-up, the FAA, mLDFA, LPD, and TT-TG were (15.6±2.7)°, (83.0±2.1)°, (5.0±2.6) mm, and (20.5±2.5) mm, respectively; the VAS score, Lysholm score, Tegner score, and Kujala score were 2.4±1.4, 93.4±7.8, 6.8±1.5, and 89.0±8.0, respectively. There were significant differences in the above indicators between pre- and post-operation (P<0.05). ConclusionDDFO combined with MPFL reconstruction for the recurrent patellar dislocation with excessive FAA (≥30°) can achieve good short-term effectiveness, significantly reduce knee pain, and improve function.
ObjectiveTo investigate the lateral wall protection skills for aged femoral intertrochanteric fractures fixed with proximal femoral nail antirotation (PFNA).
MethodsSixty aged patients with femoral intertrochanteric fractures were treated with PFNA between March 210 and January 2011.According to Evans classification,31 were type Ⅰc,18 were Ⅰd,and 11 were type Ⅱ.Several skills were applied to prevent the breaking of the lateral wall.Post-operative complications,bone union and recovery of hip function were recorded.
ResultsThe patients were followed up for 12 to 18 months.All fractures were healed without infection or failure of internal fixation.
ConclusionPFNA is a good choice for the clinical treatment of unstable femoral intertrochanteric fractures in aged patients.To obtain better clinical result,the lateral wall must be considered and well protected.
ObjectiveTo compare the effectiveness of long and short proximal femoral nail anti-rotation (PFNA) in the treatment of type A2.3 intertrochanteric fracture of femur (IFF). Methods The clinical data of 54 patients with type A2.3 IFF admitted between January 2020 and December 2022 were retrospectively analyzed. According to the length of PFNA nail used in the operation, they were divided into long nail group (PFNA nail length>240 mm, 24 cases) and short nail group (PFNA nail length≤240 mm, 30 cases). There was no significant difference in baseline data such as gender, age, fracture side, body mass index, and time from fracture to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, intraoperative reduction quality score, fracture healing, and complications of the two groups were recorded and compared. Harris score was used to evaluate the hip function of patients at 1 year after operation. According to the relationship between the fracture line of type A2.3 IFF and the lesser trochanter, the two groups of patients were divided into type Ⅰ(the fracture line extends to the level of the lesser trochanter), type Ⅱ(the fracture line extends to less than 2 cm below the lesser trochanter), and type Ⅲ (the fracture line extends to more than 2 cm below the lesser trochanter), and the postoperative stability and internal fixator loosening of each subtype were evaluated. Results The operation time, intraoperative blood loss, and intraoperative fluoroscopy frequency in short nail group were significantly less than those in long nail group (P<0.05). There was no significant difference in the intraoperative reduction quality score between the two groups (P>0.05). Patients in both groups were followed up 12-18 months, with an average of 13.5 months. The postoperative stability score of short nail group was significantly lower than that of long nail group (P<0.05). The Harris score in the long nail group was significantly higher than that in the short nail group at 1 year after operation (P<0.05), but there was no significant difference in Harris score grading between the two groups (P>0.05). Complications occurred in 3 cases of the long nail group (including 1 case of coxa varus caused by external nail entry point and 2 cases of loose internal fixator), and 7 cases of the short nail group (including 1 case of coxa varus caused by external nail entry point and 6 cases of loose internal fixator). Neither group had any anterior femoral arch damage, there was no significant difference in the incidence of complications between the two groups (P>0.05). The number of type Ⅲ patients was relatively small and not included in the statistics; there was no significant difference in the postoperative stability score and the incidence of internal fixator loosening between the long and short nail groups in type Ⅰ patients (P>0.05). In type Ⅱ patients, the postoperative stability score and the incidence of internal fixation loosening in the long nail group were significantly better than those in the short nail group (P<0.05).Conclusion Long PFNA fixation for type A2.3 IFF has longer operation time and more intraoperative blood loss, but the overall stability of fracture is better after operation. For type A2.3 IFF with fracture line extending to less than 2 cm below the lesser trochanter, long PFNA is used for fixation, although the surgical trauma is large, but the postoperative stability is better than that of short PFNA; for type A2.3 IFF with fracture line extending to the lesser trochanter, there is no significant difference in postoperative stability between long and short PFNAs.
Objective To investigate the feasibility and effectiveness of precise-guided temporary fixation assistive devices in assisting the main nail guide pin placement and precise temporary fixation in proximal femoral nail antirotation (PFNA) internal fixation of femoral intertrochanteric fractures. Methods A prospective randomized controlled study was conducted to analyze the clinical data of 60 patients with femoral intertrochanteric fractures over 65 years old who met the selection criteria between January 2020 and June 2022 and were treated with PFNA internal fixation. The patients were randomly divided into the trial group (auxiliary device guided main nail guide pin placement and temporary fixation) and the control group (conventional treatment), with 30 cases in each group. There was no significant difference in baseline data such as gender, age, cause of injury, time from injury to operation, fracture side, AO/Orthopaedic Trauma Association (AO/OTA) classification, and combined medical diseases between the two groups (P>0.05). The operation time, times of main nail guide pin placement, intraoperative fluoroscopy frequency, intraoperative blood loss, and perioperative blood transfusion were recorded and compared between the two groups. The quality of fracture reduction was evaluated by CHANG Shimin et al criteria. Harris score was used to evaluate the hip function at 1 year after operation. Results In the trial group, 2 temporary fixation needles were successfully placed 2-5 times, including 2 times in 13 cases (43.3%), 3 times in 8 cases (26.7%), 4 times in 7 cases (23.3%), and 5 times in 2 cases (6.7%). The operation time, times of main nail guide pin placement, intraoperative fluoroscopy frequency, and intraoperative blood loss in the trial group were significantly less than those in the control group, and the reduction quality score was significantly better than that in the control group (P<0.05). There was no significant difference in perioperative blood transfusion between the two groups (P>0.05). All patients were followed up 12-19 months (mean, 15 months). There was no complication such as incision infection, deep vein thrombosis, or internal fixation loosening. At 1 year after operation, the Harris score of the affected hip joint in the trial group was significantly higher than that in the control group (P<0.05). Conclusion The technique of main nail guide pin placement and temporary fixation under the guidance of auxiliary devices in PFNA internal fixation can achieve faster insertion of the main nail guide pin, accurate temporary fixation to maintain reduction, and avoid the subsequent operation space, so as to improve the effectiveness.
ObjectiveTo improve health care quality and safety by monitoring the performance of PhilipsPrecedence Dual-head single photon emission computed tomography (SPECT).
MethodsWith our own homemade point source and the center of rotation model, in accordance with NEMA standards and manufacturers' design conditions, these three indicators including energy peak position of the instrument, intrinsic uniformity and center of rotation were routinely tested between 2008 and 2012 for the Philips-Precedence Dual-head SPECT in our hospital. In addition, the quality control was performed twice a week, and every year the total number of quality control was basically the same. We calculated the results by the weighted average method.
ResultsThe 5-year average energy peaks of detector 1 and 2 were (139.23±0.32) and (138.97±0.45) keV, respectively, and they were both within the range of reference values [(140±3) keV]. In addition, the results of center of rotation were also in the normal range, and kept stable. Based on the analysis of quality-control data, for detector 1, compared with the data of 2008, there was no significant diTherence for central field of vision (CFOV) and useful field of vision (UFOV) in these three years from 2009 to 2011 (P>0.05). The diTherence was only significant between data of 2008 and that of 2012 (P<0.05). For detector 2, compared with the data of 2008, there was no significant diTherence for CFOV and UFOV in 2009 and 2011(P>0.05), while there was significant diTherent in 2010 and 2012 (P<0.05).
ConclusionThe uniformity of SPECT will gradually deteriorate with prolonged use. However, regular quality control and maintaining can keep the function stabilization, and enhance the availability rate.