Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
Objective To systematically evaluate the difference in leg length discrepancy (LLD) between robot-assisted total hip arthroplasty (THA) and traditional THA. Methods The Cochrane Library, PubMed, Web of Science, EMbase, CNKI, Wanfang, VIP, and CBM databases were searched by computer to collect cohort studies of robot-assisted and traditional THAs from inception to August 11th, 2021. Two researchers independently screened the literature, extracted the data, and evaluated the risk of bias of the included studies. Meta-analysis was performed using RevMan 5.3 software. ResultsA total of 10 high-quality cohort studies were included. The results of Meta-analysis showed that compared with traditional THA, LLD after robot-assisted THA was smaller [MD=?1.64, 95%CI (?2.25, ?1.04), P<0.001], Harris scores at 3 and 12 months after operation were higher [MD=1.50, 95%CI (0.44, 2.57), P=0.006; MD=7.60, 95%CI (2.51, 12.68), P=0.003]. However, the operative time was longer [MD=8.36, 95%CI (4.56, 12.17), P<0.000 1], and the postoperative acetabular anteversion angle was larger [MD=1.91, 95%CI (1.43, 2.40), P<0.001]. There was no significant difference in Harris score at 6 months, amnesia index (Forgotten joint score, FJS), postoperative acetabular abduction angle, and incidence of complication between the two groups (P>0.05). Conclusion Robot-assisted THA is superior to traditional THA in postoperative LLD.
Objective To review research advances of revision surgery after primary total hip arthroplasty (THA) for patients with Crowe type Ⅳ developmental dysplasia of the hip (DDH). Methods The recent literature on revision surgery after primary THA in patients with Crowe type Ⅳ DDH was reviewed. The reasons for revision surgery were analyzed and the difficulties of revision surgery, the management methods, and the related prosthesis choices were summarized. Results Patients with Crowe type Ⅳ DDH have small anteroposterior diameter of the acetabulum, large variation in acetabular and femoral anteversion angles, severe soft tissue contractures, which make both THA and revision surgery more difficult. There are many reasons for patients undergoing revision surgery after primary THA, mainly due to aseptic loosening of the prosthesis. Therefore, it is necessary to restore anatomical structures in primary THA, as much as possible and reduce the generation of wear particles to avoid postoperative loosening of the prosthesis. Due to the anatomical characteristics of Crowe type Ⅳ DDH, the patients have acetabular and femoral bone defects, and the repair and reconstruction of bone defects become the key to revision surgery. The acetabular side is usually reconstructed with the appropriate acetabular cup or combined metal block, Cage, or custom component depending on the extent of the bone defect, while the femoral side is preferred to the S-ROM prosthesis. In addition, the prosthetic interface should be ceramic-ceramic or ceramic-highly cross-linked polyethylene wherever possible. Conclusion The reasons leading to revision surgery after primary THA in patients with Crowe type Ⅳ DDH and the surgical difficulties have been clarified, and a large number of clinical studies have proposed corresponding revision modalities based on which good early- and mid-term outcomes have been obtained, but further follow-up is needed to clarify the long-term outcomes. With technological advances and the development of new materials, personalized prostheses for these patients are expected to become a reality.
Objective To investigate the changes of low back pain (LBP) and spinal sagittal parameters in patients with unilateral Crowe type Ⅳ developmental dysplasia of the hip (DDH) after total hip arthroplasty (THA). Methods The clinical data of 30 patients who met the selection criteria between October 2018 and March 2020 were retrospectively analyzed. Patients were divided into LBP group (16 cases) and control group (14 cases) according to whether there was LBP before operation. There was no significant difference between the two groups of patients in gender, age, body mass index, affected sides, preoperative Harris score (P>0.05). Full-length lateral X-ray films of the spine were taken within 1 week before operation and at 1 year after operation, and the following imaging indicators were measured: sacral slope (SS), lumbar lordosis (LL ), spinal tilt (ST), spine-sacral angle (SSA), sagittal vertebral axis (SVA). The visual analogue scale (VAS) score, lumbar Oswestry disability index (ODI), the Harris score of the hip joint before operation and at 1 year after operation, and the occurrence of postoperative complications were collected and analysed. Results In the LBP group, LBP was relieved to varying degrees at 1 year after operation, of which 13 patients (81.3%) had complete LBP remission; VAS score decreased from 4.9±2.3 preoperatively to 0.3±0.8, ODI decreased from 33.5±22.6 preoperatively to 1.3±2.9, the differences were all significant (t=7.372, P=0.000; t=5.499, P=0.000). There was no new chronic LBP in the control group during follow-up. The Harris scores of the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between the two groups at 1 year after operation (t=0.421, P=0.677). There was no significant difference in imaging indexes between the two groups before operation and the difference between pre- and post-operation (P>0.05). At 1 year after operation, ST and SVA in the LBP group, SSA in the control group, and SS in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the other indexes between the two groups before and after operation (P>0.05). Conclusion Unilateral Crowe type Ⅳ DDH patients with LBP before operation were all relieved of LBP after THA. The relief of LBP may be related to the improvement of spinal balance, but not to lumbar lordosis and its changes.
Objective
To evaluate the safety and efficacy of total hip arthroplasty (THA) in patients with end stage renal disease (ESRD).
Methods
Between December 2009 and May 2016, 30 THAs were performed in 28 patients with dialysis-dependent renal failure (18 patients) or renal transplantation (10 patients). A retrospective case control study was carried out to compare these 28 ESRD patients (ESRD group) with a matched cohort of 28 nonrenal patients (control group). There was no significant difference in gender, age, hip side, American Society of Anesthesiology (ASA) classification, comorbidities, and preoperative Harris score and hemoglobin (Hb) level between 2 groups (P>0.05). The complications during hospitalization, Hb level changes, perioperative transfusion rate, hospital stay, and hospitalization costs in 2 groups were evaluated; and the creatinine changes of dialysis patients in ESRD group were evaluated. During the follow-up period, 90 days readmissions, periprosthetic infection, prosthesis loosening, hip Harris score, and deaths were recorded.
Results
There was no loss of follow-up. The mean postoperative follow-up of ESRD group was 3.4 years (range, 1.0-7.4 years) and control group was 3.5 years (range, 1.0-7.4 years). Differences in hospital stay and the drop of Hb was not significant between 2 groups (P>0.05). The hospitalization costs and perioperative transfusion rate were significantly higher in ESRD group than in control group (P<0.05). There was no significant difference in creatinine value of dialysis patients in ESRD group between pre- and post-operation (t=1.804, P=0.089). At last follow-up, the Harris score was significantly higher than preoperative score in both groups (P<0.05); however, there was no significant difference in Harris score between groups (t=1.278, P=0.207). In ESRD group, 5 patients presented complications, 1 patient was readmitted to hospital, and 2 patients died during the follow-up. In control group, 1 patient presented complications, and there was no 90 days readmission and no death. During the follow-up period, there was no loosening or revision in 2 groups and the prosthesis was in good position.
Conclusion
THA can improve joint function and life quality of ESRD patients, but the risks of operation, perioperative complications, transfusion rate, and cost are high. Correct perioperative evaluation and management can help ESRD patients safely go through the perioperative period.
Objective To investigate the effectiveness of MAKO robotic-arm assisted total hip arthroplasty (THA) via direct anterior approach (DAA) for bony fused hips in ankylosing spondylitis (AS). Methods Between June 2021 and January 2022, MAKO robotic-arm assisted THA via DAA was applied to treat 10 cases (12 hips) of AS with bony fused hips. There were 7 males and 3 females; the age ranged from 30 to 71 years, with an average age of 42.4 years. The duration of AS was 12-35 years, with an average of 21.4 years. The preoperative hip was ankylosed in flexion in 3 cases, with a flexion angle of 20°, 30°, 35°, respectively; 9 cases were ankylosed in extension. The operation time and complications were recorded; the visual analogue scale (VAS) score, Harris score, and Oxford hip scale (OHS) score before and after operation, and postoperative range of motion (flexion, extension, internal rotation, external rotation, adduction, and abduction) were used to evaluate the recovery of joint function; according to the postoperative anteroposterior X-ray film and CT scan of both hip joints, the abduction angle, anteversion angle, the difference between bilateral combined off-set and the lower limb length discrepancy were measured. Results The operation time ranged from 80 to 190 minutes (mean, 134.6 minutes). All 10 patients were followed up 5-11 months (mean, 7.4 months). There was no serious adverse events such as incision infection, deep vein thrombosis of lower extremities, hip redislocation, aseptic loosening of the prosthesis, or death. At 5 months after operation, the acetabular prosthesis angle of abduction was 37°-45° (mean, 40.3°), anteversion angle was 9°-20° (mean, 15.8°). The difference between bilateral combined off-set was 0-10 mm (mean, 4.3 mm); the lower limb length discrepancy was 0-12 mm (mean, 3.5 mm). At last follow-up, the average range of motion of the hip joint was 89.2° in flexion (range, 80°-100°), 1.7° in extension (range, –5°-10°), 7.1° in internal rotation (range, 0°-15°), 20.4° in external rotation (range, 10°-30°), 7.9° in adduction (range, 0°-20°), and 16.5° in abduction (range, 10°-25°). At last follow-up, the VAS score, Harris score, and OHS score significantly improved when compared with those before operation (P<0.05). ConclusionThe MAKO robotic-arm assisted THA via DAA can achieve satisfactory results in the treatment of AS with bony fused hip, which has the advantages of accurate prosthesis installation, soft tissue release, and less trauma during operation.
ObjectiveTo investigate the accuracy of preoperative digital-template planning in total hip arthroplasty (THA) via direct anterior approach (DAA) and its effect on the short-term effectiveness.MethodsThe clinical data of 77 patients (109 hips) with osteonecrosis of femoral head who underwent THA via DAA between January 2016 and May 2018 was retrospectively analyzed. According to the type of template, patients were divided into digital-template group (group A, 40 patients, 56 hips) and conventional-template group (group B, 37 patients, 53 hips). There was no significant difference in age, gender, body mass index, the stages of osteonecrosis of femoral head, and preoperative Harris hip score (HHS) (P>0.05). The operation time, intraoperative blood loss, frequencies of intraoperative fluoroscopy, and complications were recorded. Otherwise, the consistency rate of preoperative planning and practical prosthesis size was analyzed. Position of acetabular prosthesis and femoral prosthesis alignment were measured on anteroposterior X-ray film of the pelvis at 3 months after operation. HHS was used to evaluate clinical function.ResultsThe consistency rate of preoperative planning and practical acetabular prosthesis size was significantly higher in group A (80.4%, 45/56) than that in group B (62.3%, 33/53), showing significant difference (χ2=4.38, P=0.04). But there was no significant difference in the consistency rate of preoperative planning and practical femoral prosthesis size between group A (83.9%, 47/56) and group B (79.2%, 42/53)(χ2=0.40, P=0.53). The prosthesis abductions were (40.7±6.4)° in group A and (38.8±7.3)° in group B; the femoral prosthesis alignment deviations were (0.1±1.8)° in group A and (0.3±1.7)° in group B. There was no significant difference in the prosthesis abduction and femoral prosthesis alignment deviation between 2 groups (P>0.05). No prosthesis sinking or loosening occurred during follow-up. The operation time and frequencies of intraoperative fluoroscopy were less in group A than those in group B (P<0.05). But there was no significant difference in intraoperative blood loss between 2 groups (t=1.92, P=0.06). The complication occurred in 1 hip of group A and 6 hips of group B, with no significant difference (P=0.06). All patients were followed up 6-22 months (mean 13.8 months) in group A and 6-24 months (mean, 14.6 months) in group B. At last follow-up, the HHS scores were 91.8±3.1 in group A and 92.6±4.2 in group B, and the difference was not significant (t=1.14, P=0.26).ConclusionPreoperative digital-template planning in THA via DAA is accurate, which can reduce the operation time and frequencies of intraoperative fluoroscopy without enhancing the risk of complication.
Objective To evaluate the effectiveness of the shared decision-making scheme in postoperative out-of-hospital extended care for patients with total hip/knee arthroplasty (THA/TKA). Methods Patients who underwent THA/TKA in the Department of Orthopedic Surgery at West China Hospital of Sichuan University between October 2023 and April 2024 were included using convenience sampling. Patients were divided into the control group (odd-numbered dates) and the intervention group (even-numbered dates) based on the surgical dates. The intervention group was received care guided by a shared decision-making protocol, whereas the control group was followed the standard post-arthroplasty follow-up procedures. Differences between the two groups were compared in terms of decision-making capacity, decision satisfaction, and hip/knee function at the following time points: on the day of discharge, 3 weeks after discharge, 2 months after discharge, and 3 months after discharge. Results A total of 118 patients were included, with 59 cases in each group. There were no significant differences in demographic and clinical characteristics between the two groups (P>0.05). In terms of decision-making, compared with the control group, the experimental group had stronger decision-making ability, lower decision-making conflict, and more satisfaction with the decision-making process (P<0.05). In terms of joint function, the experimental group showed better joint function than the control group at 3 weeks, 2 months, and 3 months after surgery (P<0.05). There was no significant difference in the pain dimension of the Western Ontario and McMaster Universities Osteoarthritis index between the two groups (P=0.199). Conclusions Compared with the traditional follow-up protocol, the shared decision-making protocol can enhance patient engagement in medical decision-making, reduce decisional conflict, improve satisfaction with the decision-making process, and simultaneously promote joint functional recovery and expedite the rehabilitation process.
Objective By comparing with the traditional X-ray template measurement method, to explore the accuracy of artificial intelligence preoperative planning system (AI-HIP) to predict the type of prosthesis and guide the placement of prosthesis before total hip arthroplasty (THA) in adult patients with developmental dysplasia of the hip (DDH). Methods Patients with DDH scheduled for initial THA between August 2020 and August 2022 were enrolled as study object, of which 28 cases (28 hips) met the selection criteria were enrolled in the study. Among them, there were 10 males and 18 females, aged from 34 to 77 years, with an average of 59.3 years. There were 12 cases of the left DDH and 16 cases of the right DDH. According to DDH classification, there were 10 cases of Crowe type Ⅰ, 8 cases of type Ⅱ, 5 cases of type Ⅲ, and 5 cases of type Ⅳ. According to Association Research Circulation Osseous (ARCO) staging of osteonecrosis of the femoral head, 13 cases were in stage Ⅲ and 15 cases in stage Ⅳ. The disease duration was 2.5-23.0 years (mean, 8.6 years). The limb length discrepancy (LLD) was 11.0 (8.0, 17.5) mm. Before operation, the prosthesis types of all patients were predicted by AI-HIP system and X-ray template measurement method, respectively. And the preoperative results were compared with the actual prosthesis type during operation in order to estimate the accuracy of the AI-HIP system. Then, the differences in the acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, tip-shoulder distance, and LLD were compared between preoperative planned measurements by AI-HIP system and actual measurement results after operation, in order to investigate the ability of AI-HIP system to evaluate the placement position of prosthesis. Results The types of acetabular and femoral prostheses predicted based on AI-HIP system before operation were consistent with the actual prostheses in 23 cases (82.1%) and 24 cases (85.7%), respectively. The types of acetabular and femoral prostheses predicted based on X-ray template measurement before operation were consistent with the actual prostheses in 16 cases (57.1%) and 17 cases (60.7%), respectively. There were significant differences between AI-HIP system and X-ray template measurement (P<0.05). There was no significant difference in acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, and tip-shoulder distance between AI-HIP system and actual measurement after operation (P>0.05). LLD after operation was significantly lower than that before operation (P<0.05). There was no significant difference between the LLD predicted based on AI-HIP system and the actual measurement after operation (P>0.05). Conclusion Compared with the traditional X-ray template measurement method, the preoperative planning of AI-HIP system has better accuracy and repeatability in predicting the prosthesis type. It has a certain reference for the prosthesis placement of adult DDH.
Objective To compare the early effectiveness between by anterior approach via Bikini incision and by OCM approach in the primary total hip arthroplasty (THA). Methods Between June 2015 and March 2016, 60 patients with ischemic necrosis of the femoral head who accorded with the inclusion criteria were chosen in the study, who were divided into 2 groups according to different surgical approaches. THA was performed on 30 patients by anterior approach via Bikini incision (group A), and on 30 patients by OCM approach (group B). There was no significant difference in age, gender, body mass index, side of affected hip, Steinberg stage of ischemic necrosis of femoral head, preoperative hemoglobin, preoperative Harris score, and preoperative visual analogue scale (VAS) between 2 groups (P>0.05). The operation time, length of incision, intraoperative blood loss, transfusion rate, starting time of straight leg raising exercise, starting time of active abduction of hip, hospitalization time, the incidence of limb length discrepancy, postoperative Harris score and VAS score were recorded and compared between 2 groups. Anteroposterior pelvic X-ray films were taken to measure acetabular abduction and acetabular anteversion. Results Primary healing of incision was obtained in all patients of 2 groups, and there was no significant difference in complication between 2 groups (χ2=0.144,P=0.704). All the patients of 2 groups were followed up 3 to 12 months, averaged 6 months. There was no significant difference in operation time, length of incision, intraoperative blood loss, transfusion rate, hospitalization time, and starting time of straight leg raising exercise between 2 groups (P>0.05). Group A was significantly shorter than group B in starting time of active abduction of hip (t=–4.591,P=0.000), and was significantly lower than group B in the incidence of limb length discrepancy (χ2=5.455,P=0.020). After operation, neither Harris score at 2 weeks, 6 weeks, 3 months, and 6 months nor VSA score at 24 hours and 6 weeks showed significant difference between 2 groups (P>0.05). The anteroposterior pelvic X-ray films showed that all the prostheses were in good position, and there was no femoral prosthesis subsidence, acetabular cup displacement or dislocation. No significant difference was found in acetabular abduction and acetabular anteversion at 2 days after operation between 2 groups (t=0.887,P=0.379;t=0.652,P=0.517). Conclusion Both of two approaches in THA can avoid muscle damage and achieve favorable short-term effectiveness. But, anterior approach via Bikini incision is superior to OCM approach in starting time of active abduction of hip and the incidence of limb length discrepancy.