1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "valve disease" 40 results
        • Experimental Research on Sheep Mitral Valves Replacement with Stentedpulmonary Autograft

          Objective To investigate the feasibility and effect of stentedpulmonary autograft replacement and find out the best way to treat mitral valve diseases. Methods From August 2006 to October 2007, 20 male sheep at the age of about 1 year old underwent mitral valves replacement operation in Anzhen Hospital. Weight of these sheep was 50.0±6.0 kg. They were randomly divided into two groups. Ten sheep in the experimental group underwent RossⅡsurgery in which we first sutured pulmonary valve onto a pulmonary valve stent, transferred the valve to the mitral valve annulus and then reestablished the outflow tract of the right ventricle. The other 10 sheep in the control group underwent bioprosthetic valve replacement routinely. Ultrasonic cardiogram (UCG) was employed 6 hour after operation to measure the effective orifice area (EOA) of the mitral valve, mitral peak velocity of early filling, the peak pressure gradient (PPG), the extent of regurgitation, left ventricular enddiastolic dimension (LVEDD) and ejection fraction (EF). Results One sheep in the experimental group died of low cardiac output syndrome; one in the control group died of unmanageable bleeding during operation, and the others all survived. Six hours after operation, UCG of the experimental group showed that the heart valves were well fixed, valve echo was clear, and there was no perivalvular leakage or mitral valve stricture or regurgitation, but moderate pulmonary valve regurgitation occurred in 1 case and mild in 2. There was no significant difference between the two groups in PPG (11.86±1.28 mm Hg vs. 10.98±0.98 mm Hg,t= 1.670,P=0.110) and the mitral peak velocity of early filling (1.72±0.09 m/s vs. 1.65±0.07 m/s, t=1.680,P=0.110). However, EOA of the experimental group was smaller than the control group (2.23±0.09 cm2 vs. 2.39±0.08 cm2, t= 4.240,P= 0.001). Conclusion The experimental result of sheep mitral valves replacement with stentedpulmonary autograft is satisfying. The new mitral valves work well and the surgery method is feasible.

          Release date:2016-08-30 06:02 Export PDF Favorites Scan
        • Short-term clinical efficacy of one-stop TAVR+PCI in the treatment of patients with aortic valve disease and coronary heart disease

          ObjectiveTo analyze the short-term clinical efficacy and prognosis of one-stop transcatheter aortic valve replacement (TAVR)+percutaneous coronary intervention (PCI) in the treatment of aortic valve disease with coronary heart disease. MethodsThe clinical data of patients with aortic valve disease complicated with coronary heart disease who underwent one-stop TAVR+PCI treatment at the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University from January 2018 to June 2023 were retrospective analyzed. The preoperative and postoperative clinical data were compared, and 1-month follow-up results were recorded. ResultsA total of 37 patients were enrolled, including 22 males and 15 females, with an average age of 69.14±6.47 years. Thirty-six patients recovered and were discharged after the surgery, and 1 (2.7%) patient died during the surgery. Self-expanding TAVR valves were implanted through the femoral artery in all patients. One coronary artery was opened by PCI in 35 (94.6%) patients, and two coronary arteries were opened by PCI in 2 (5.4%) patients. All PCI opened arteries had a stenosis>70%. During the postoperative hospitalization, the complications included pulmonary infection in 11 (30.6%) patients, severe pneumonia in 10 (27.8%) patients, liver function injury in 14 (38.9%) patients, renal function injury in 5 (13.9%) patients, cerebral infarction in 1 (2.8%) patient, atrial fibrillation in 1 (2.8%) patient, ventricular premature beats in 2 (5.6%) patients, atrioventricular block in 2 (5.6%) patients, and complete left bundle branch block in 5 (13.9%) patients. The median postoperative ventilation assistance time was 12.0 (0.0, 17.0) h, the ICU monitoring time was 1.0 (0.0, 2.0) d, and the postoperative hospitalization time was 5.0 (4.0, 7.0) d. There was a significant improvement in the New York Heart Association cardiac function grading after surgery (P<0.001). After surgery, there were 21 (58.3%) patients had minor perivalve leakage, 6 (16.7%) patients had minor to moderate perivalve leakage, and no moderate or above degree of perivalve leakage. After one month of postoperative follow-up, 36 patients showed significant improvement in heart function. There were no patients with recurrent acute coronary syndrome, re-PCI, or cardiovascular system disease related re-hospitalization. ConclusionThe one-stop TAVR+PCI treatment for patients with aortic valve disease and coronary heart disease can obtain satisfactory short-term clinical efficacy, which is worth further trying and studying.

          Release date:2024-05-28 03:37 Export PDF Favorites Scan
        • Transcatheter aortic valve replacement for severe aortic stenosis complicated by severe scoliosis: a case report

          Patients with severe aortic stenosis will gradually develop symptoms of heart failure. Aortic valve replacement is an effective treatment at present, while transcatheter aortic valve replacement is suitable for high-risk elderly patients. This article reports a patient with severe aortic valve stenosis and severe scoliosis who underwent transcatheter aortic valve replacement. Detailed preoperative evaluation and avoidance of peripheral vascular injury were the characteristics of this case. The patient was an elderly male with severe scoliosis. After fully evaluating the risks and benefits of surgery, a surgical strategy was formulated. The patient was in the supine position to complete the preoperative CT, and then the long sheath was used to pass through the thoracoabdominal aortic angle during the operation. After angiography-assisted adjustment and determination of the optimal release angle, the valve was accurately released, and the operation went smoothly without serious peripheral vascular damage.

          Release date:2022-05-24 03:47 Export PDF Favorites Scan
        • Preliminary experience of Ozaki procedure for adult aortic valve disease in a single center

          ObjectiveTo explore the short-term efficacy and safety of Ozaki surgery in treating adult patients with aortic valve disease and to summarize clinical experience. MethodsClinical data of adult patients with aortic valve disease who underwent Ozaki surgery in the Department of Cardiovascular Surgery, Beijing Anzhen Hospital of Capital Medical University Nanchong Branch in 2025 were collected, and the effectiveness and safety of Ozaki surgery were analyzed. ResultsA total of 5 patients were included, including 3 males and 2 females, with an average age of (47.80±12.99) years. One patient was aortic stenosis, 2 patients were aortic regurgitation, and 2 patients were aortic stenosis combined with regurgitation. Two patients underwent isolated Ozaki surgery, 1 patient underwent Ozaki+coronary artery bypass surgery, and 2 cases underwent Ozaki+mitral valve plasty+tricuspid valve plasty. The average operation time was (6.70±1.25) hours. The average extracorporeal circulation time was (217.20±59.47) minutes, the average aortic cross-clamping time was (153.60±45.71) minutes, the average postoperative ventilator support time was (25.00±11.79) hours, the average intensive care unit stay was (2.43±1.30) days, and the average postoperative hospital stay was (11.20±1.92) days. The postoperative average aortic valve flow rate was (1.70±0.26) m/s, and the average transvalve pressure gradient was (11.00±1.87) mm Hg. Postoperatively, 3 patients had no aortic regurgitation, and 2 patients had trace regurgitation. Postoperative complications included pulmonary infection in 3 patients, severe pneumonia in 1 patient, liver function damage in 4 patients, and renal function damage in 3 patients. No patients experienced arrhythmias or other complications. All 5 patients recovered and were discharged, and their cardiac function significantly improved postoperatively compared to preoperatively (P<0.001), with both left ventricle (P=0.047) and left atrium (P=0.016) reduced in size. ConclusionThe short-term results of Ozaki surgery for adult patients with aortic valve disease are satisfied, but long-term outcomes still need further exploration.

          Release date: Export PDF Favorites Scan
        • The Partial Application of Complete Flexible Artifical Ring in Mitral Valve Repair

          Objective To summarize the experience and results of mitral annuloplasty with modified partial flexible artificial ring. Methods Two hundred and fifteennine patients were underwent partial flexible ring annuloplasty after mitral valve plasty surgery in our hospital from an. 1998 to Aug.2006. The etiology included rheumatic (16 cases), infective endocarditis of mitral (16 cases), ischemic (13 cases), ongenital (40 cases) and degeneration (174 cases). Echocardiogram test were performed in the perioperative periods to monitor the lefe atrium (LA), left ventricular enddiastolic dimension (LVEDD), left ventricular endsystolic dimension (LVESD), left ventricular ejection fraction(LVEF), left ventricular fractional shortening (LVFS) and mitral regurgitation grades. The perioperative mortality, morbidity, reoperation rate were recorded during the followup. Results Aortic cross clamping time was 74±30 min and cardiopulmonary bypass time was 105±37min. The perioperative survival rate was 96.5% (250/259) and free from complications rate was 93.4% (242/259). No left ventricular out flow tract obstruction and coronary artery stenosis were occurred in this group. The 60 months survival rate was 938% (243/259) and 5 years nonreoperation rate was 96.1%(249/259). The perioperative echocardiogram results showed the LVEDD decreased from 62.60±10.19mm to 52.88±8.67mm and the LVEF increased from 57.91% to 61.00%(Plt;0.05). During the followup the mitral regurgitation grades were improved significantly (Plt;0.05),there were 188 cases of trifle mitral regurgitation (72.6%), 62 cases of mild mitral regurgitation (23.9%), 8 cases of moderate mitral regurgitation(3.1%) and 1 case of serious mitral regurgitation(0.4%). Conclusion This simplified mitral annuloplasty technique is an easy handling and effective treatment for the mitral repair.

          Release date:2016-08-30 06:08 Export PDF Favorites Scan
        • Cryomaze ablation in treatment of elderly patients with mitral valve diseases combined with persistent or long-term persistent atrial fibrillation: A propensity-score matching study

          ObjectiveTo evaluate the safety and efficacy of mitral valve surgery and cryoablation in elderly patients with mitral valve disease and persistent or long-term persistent atrial fibrillation.MethodsFrom May 2014 to July 2018, 144 patients with mitral valve diseases combined with persistent or long-term persistent atrial fibrillation in the Department of Cardiothoracic Surgery, General Hospital of Northern Theater Command were selected. Among them, there were 69 patients in a non-elderly group (<60 years) including 18 males and 51 females aged 52.07±5.56 years, and 75 patients in an elderly group (≥60 years) including 32 males and 43 females aged 65.23±4.29 years. A propensity-score matching (PSM) study was conducted to eliminate confounding factors. Both groups underwent mitral valve surgery and cryoablation at the same time. A 2-year follow-up was conducted after discharge from the hospital, and the perioperative and postoperative efficacy indexes were compared between the two groups.ResultsAfter PSM analysis, there were 56 patients in each group. The sinus rhythm conversion rate of the two groups at each follow-up time point was above 85%, and the cardiac function was graded asⅠorⅡ, which was significantly improved compared with that before the surgery, but there was no statistical difference between the two groups (P>0.05). Among the perioperative indicators of the two groups, the elderly group had more coronary artery bypass graft surgeries and longer postoperative ICU stay time compared with the non-elderly group (P<0.05), and the differences in other indicators were not statistically different (P>0.05).ConclusionThe mitral valve surgery and cryoablation in elderly patients with mitral valve diseases combined with persistent or long-term persistent atrial fibrillation are safe, and the short-term outcome is satisfactory.

          Release date:2022-06-24 01:25 Export PDF Favorites Scan
        • Tricuspid Valve Replacement: Medium-and Long-term Results in 67 Cases

          Objective To analyze the medium-and long-term r esults of tricuspid valve replacement(TVR), to summarize the experience in opera tive therapy for tricuspid valve disease. Methods From January 1998 to May 2006, sixty seven patients had undergone TVR. The etiology was rheumatic disease in 25 cases, congenital disease in 37 cases, degenerative disease in 1 case, infective endocarditis in 3 cases, a nd cardiac tumor in 1 case. All operations were performed under general anesthes i a and by cardiopulmonary bypass. Bioprostheses was replaced in 28 patients, whil e mechanical valve was replaced in 39 patients. Associated procedure included mi tral valve replacement in 13 cases, mitral valve replacement and aortic valve replac ement in 12 cases, repair of ventricular septal defect in 1 case, repair of atri al septal defect in 1 case, and radioablation of atrial fibrillation in 3 case s. Results The operative mortality was 11.94% (8/67),among these patients , 6 cases died of serious heart failure,1 case died of ventricular fibrillation, 1 case died of multi organ failure. During follow-up, 1 patient died of biopro thesis dysfunction 1 year after the operation, 1 patient died of cerebral emboli s m 6 years after the operation. Through statistical analysis, it showed that the mortality of TVR in rheumatic tricuspid valve disease was higher than that in co ngenital tricuspid valve disease [5.56%(2/36)vs. 24.00% (6/25); χ2=4.425 , P=0.036]; the mortality in second time operation was higher than that in first time operation [30.00%(3/10)vs. 8.77% (5/57);χ2=3.646,P=0.033 ]; while there was no significant difference in immediate and long-term result s with different choice of bioprosthetic or mechanical valve in TVR (χ2=0.002 , P=0.961). Conclusion Operative an d follow-up mortality is high in the TVR, valve replac ement is the last selection for the treatment of serious tricuspid disease, appr opriate operative technique and perioperative therapy is the key for success o f the operation.

          Release date:2016-08-30 06:09 Export PDF Favorites Scan
        • Detection method of early heart valve diseases based on heart sound features

          Heart valve disease (HVD) is one of the common cardiovascular diseases. Heart sound is an important physiological signal for diagnosing HVDs. This paper proposed a model based on combination of basic component features and envelope autocorrelation features to detect early HVDs. Initially, heart sound signals lasting 5 minutes were denoised by empirical mode decomposition (EMD) algorithm and segmented. Then the basic component features and envelope autocorrelation features of heart sound segments were extracted to construct heart sound feature set. Then the max-relevance and min-redundancy (MRMR) algorithm was utilized to select the optimal mixed feature subset. Finally, decision tree, support vector machine (SVM) and k-nearest neighbor (KNN) classifiers were trained to detect the early HVDs from the normal heart sounds and obtained the best accuracy of 99.9% in clinical database. Normal valve, abnormal semilunar valve and abnormal atrioventricular valve heart sounds were classified and the best accuracy was 99.8%. Moreover, normal valve, single-valve abnormal and multi-valve abnormal heart sounds were classified and the best accuracy was 98.2%. In public database, this method also obtained the good overall accuracy. The result demonstrated this proposed method had important value for the clinical diagnosis of early HVDs.

          Release date:2023-12-21 03:53 Export PDF Favorites Scan
        • Concomitant Tricuspid Annuloplasty for Patients with Tricuspid Valve Annulus Dilation and Mild Tricuspid Regurgitation Underwent Mitral Valve Replacement: A Randomized Controlled Trial

          ObjectiveTo investigate effect of cardiac function and tricuspid regurgitation (TR) degree of concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR), and provide an objective basis for clinical decision about concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent MVR. MethodsA total of 36 patients who underwent MVR from April to October 2013 in Department of Cardiovascular Surgery, West China Hospital, Sichuan University were enrolled in this study. Preoperative echocardiography showed mild TR and tricuspid valve annular end-diastolic dimension (TVAEDD)/body surface area (BSA)>21 mm/m2. All the 36 patients were randomly divided into a tricuspid annuloplasty group (TAPG group, n=18, including 7 males and 11 females) and a no tricuspid annuloplasty group (NTAPG group, n=18, including 6 males and 12 females). One week and 6 months postoperative echocardiography were recorded. ResultsThere were no statistical differences in age, gender, heart rate, body surface area, preoperative cardiac function (NYHA), left atrium dimension (LAD), left ventricular dimension (LVD), maximal long-axis of RA (RAmla), mid-RA minor distance (RAmmd), right ventricle dimension (RVD2), left ventricular ejection fraction (LVEF), left ventricular fractional shortening (LVFS) between the two groups (P>0.05). Six-months postoperative left atrial-ventricular diameter significantly reduced than that before surgery in the two groups (P<0.05). In the TAPG group, six-months postoperative right ventricle dimension (RVD1), right ventricular wall thickness (RVWT), tricuspid valve annular end-diastolic dimension (TVAEDD), tricuspid valve annular end-systolic dimension (TVAESD) significantly decreased, while percent shorting of tricuspid valve annulus (PSTVA) did not change significantly (P>0.05), TR degree improved significantly (P<0.05), right ventricular fractional area change (RVFAC) and right ventricular ejection fraction (RVEF) significantly increased (P<0.05). In the NTAPG group, compared with preoperative data, six-months postoperative RVD1, RVWT significantly increased, TVAEDD, TVAESD, PSTVA did not change significantly (P>0.05), RVEF reduced significantly (P<0.05), RVFAC increased significantly but less than that in the TAPG group at the same period, constituent ratio of TR changed significantly (P<0.05), but postoperative moderate or more TR were recorded in 6 patients. ConclusionConcomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR) can help to decrease RVD1, RVWT, TVAEDD and TVAESD, improve the constituent ratio of TR, and increase RVFAC and RVEF.

          Release date: Export PDF Favorites Scan
        • Applications of 3D printing technology in the treatment of mitral valve disease

          Mitral valve disease is the most common cardiac valve disease. The main treatment of mitral valve disease is surgery or interventional therapy. However, as the anatomy of mitral valve is complicated, the operation is particularly difficult. As a result, it requires sophisticated experiences for surgeons. Three-dimensional (3D) printing technology can transform two-dimensional medical images into 3D solid models. So it can provide clear spatial anatomical information and offer safe and personalized treatment for the patients by simulating surgery process. This article reviews the applications of 3D printing technology in the treatment of mitral valve disease.

          Release date:2019-04-29 02:51 Export PDF Favorites Scan
        4 pages Previous 1 2 3 4 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品