1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "ventricular assist device" 21 results
        • Predictors of myocardial recovery following left ventricular assist device implantation

          ObjectiveTo investigate the factors influencing myocardial recovery after left ventricular assist device (LVAD) implantation, aiming to identify patient characteristics associated with a higher potential for cardiac recovery and to inform clinical decision-making. MethodsThis retrospective study included consecutive patients with end-stage heart failure who underwent LVAD implantation at our institution between 2021 and June, 2025. Patients were categorized into three groups including a myocardial recovery group, an ongoing LVAD support group, and death group. Based on their postoperative outcomes, demographic, laboratory, and imaging data were compared among the groups. Multivariate logistic regression analysis was performed to identify independent predictors of myocardial recovery. Results A total of 57 patients who received an LVAD were included. Among them, 9 (15.8%) achieved myocardial recovery, 39 (68.4%) remained on LVAD support, and 9 (15.8%) died. Multivariate analysis identified younger age (OR=0.875, P=0.004) and a smaller preoperative left ventricular end-systolic diameter (LVESD) (OR=0.866, P=0.047) as independent predictors of myocardial recovery. Notably, all patients in the recovery group were male and had no prior implantation of an implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator. Furthermore, a higher preoperative prealbumin level was significantly associated with survival (OR=1.018, P=0.024). ConclusionYounger age and a smaller preoperative LVESD are key predictors for myocardial recovery following LVAD implantation. Younger patients with a smaller LVESD exhibit a greater potential for functional recovery. Preoperative nutritional status, as indicated by prealbumin levels, may be a predictor of mortality.

          Release date: Export PDF Favorites Scan
        • Left ventricular assist devices implantation via left antero-lateral thoracotomy: A case report

          A 56-year male patient was implanted with a third generation magnetic levitation HeartCon left ventricular assist device (LVAD) for refractory heart failure through a left antero-lateral thoracotomy. Inflow cannula of the HeartCon blood pump was inserted via the left apex and outflow tract with the artificial blood vessel was sutured to the descending aorta. The operation process was smooth, the LVAD worked stably, and results of left ventricular assist was good. Implantation of HeartCon LVAD through the left antero-lateral thoracotomy is an alternative technique with less surgical complications, less trauma and satisfactory results.

          Release date:2024-11-27 02:45 Export PDF Favorites Scan
        • Research progress on unplanned readmissions in patients with left ventricular assist devices

          The implantation of left ventricular assist device (LVAD) has significantly improved the quality of life for patients with end-stage heart failure. However, it is associated with the risk of complications, with unplanned readmissions gaining increasing attention. This article reviews the influencing factors, prediction methods and models, and intervention measures for unplanned readmissions in LVAD patients, aiming to provide scientific guidance for clinical practice, assist healthcare professionals in accurately assessing patients' conditions, and develop rational care plans.

          Release date:2025-05-30 08:48 Export PDF Favorites Scan
        • Perioperative renal function in patients undergoing heart transplantation versus left ventricular assist device implantation: A retrospective cohort study

          ObjectiveTo compare the perioperative renal function changes in patients undergoing heart transplantation (HT) and left ventricular assist device (LVAD) implantation. MethodsPatients with end-stage heart failure who underwent surgical treatment at Beijing Anzhen Hospital, Capital Medical University from January 2019 to April 2024 were included. According to the surgical method, patients were divided into a HT group and a LVAD group, and the estimated glomerular filtration rate (eGFR) of patients before surgery and postoperative 1, 7, 30, 60 days was compared between the two groups. The patients with preoperative renal dysfunction were subdivided into subgroups for comparison of eGFR changes before surgery and 30 days after surgery between the two groups. ResultsA total of 112 patients were enrolled. There were 78 patients in the HT group, including 61 males and 17 females, aged (44.42±18.51) years. There were 34 patients in the LVAD group, including 30 males and 4 females, aged (54.94±11.37) years. Compared with the HT group, the average age of patients in the LVAD group was greater (P<0.001), body mass index was higher (P=0.008), preoperative eGFR was lower (P=0.009), and the proportions of smokers (P=0.017), alcohol drinkers (P=0.041), and diabetes mellitus (P=0.028) patients were higher. Among patients with preoperative renal dysfunction [eGFR<90 mL/(min·1.73 m2)], compared with the HT group, the postoperative eGFR of the LVAD group was significantly higher than that of the HT group, and it was significantly increased compared with that before surgery; the postoperative eGFR of the HT group was comparable to that before surgery, and more than half of the patients had a lower eGFR than before surgery. Among patients with preoperative renal dysfunction, 11 patients in the HT group received continuous renal replacement therapy, and 8 died early; 2 patients in the LVAD group received continuous renal replacement therapy, and 1 died early. ConclusionFor end-stage heart failure patients with combined renal dysfunction, compared with HT, LVAD implantation enables patients to obtain better renal function benefits.

          Release date:2024-11-27 02:45 Export PDF Favorites Scan
        • Study on regurgitation using the coupling model of left ventricular assist device and cardiovascular system

          Regurgitation is an abnormal condition happens when left ventricular assist devices (LVADs) operated at a low speed, which causes LVAD to fail to assist natural blood-pumping by heart and thus affects patients’ health. According to the degree of regurgitation, three LVAD’s regurgitation states were identified in this paper: no regurgitation, slight regurgitation and severe regurgitation. Regurgitation index (RI), which is presented based on the theory of dynamic closed cavity, is used to grade the regurgitation of LVAD. Numerical results showed that when patients are in exercising, resting and sleeping state, the critical speed between slight regurgitation and no regurgitation are 6 650 r/min, 7 000 r/min and 7 250 r/min, respectively, with corresponding RI of 0.401, 0.300 and 0.238, respectively. And the critical speed between slight regurgitation and severe regurgitation are 5 500 r/min, 6 000 r/min and 6 450 r/min, with corresponding RI of 0.488, 0.359 and 0.284 respectively. In addition, there is a negative relation correction between RI and rotational speed, so that grading the LVAD’s regurgitation can be achieved by determining the corresponding critical speed. Therefore, the detective parameter RI based on the signal of flow is proved to be able to grade LVAD’s regurgitation states effectively and contribute to the detection of LVAD’s regurgitation, which provides theoretical basis and technology support for developing a LVADs controlling system with high reliability.

          Release date:2017-10-23 02:15 Export PDF Favorites Scan
        • Study on sensorless suction detection method based on the intrinsic parameter of rotary left ventricular assist devices

          The rotary left ventricular assist device (LVAD) has been an effective option for end-stage heart failure. However, while clinically using the LVAD, patients are often at significant risk for ventricular collapse, called suction, mainly due to higher LVAD speeds required for adequate cardiac output. Some proposed suction detection algorithms required the external implantation of sensors, which were not reliable in long-term use due to baseline drift and short lifespan. Therefore, this study presents a new suction detection system only using the LVAD intrinsic blood pump parameter (pump speed) without using any external sensor. Three feature indices are derived from the pump speed and considered as the inputs to four different classifiers to classify the pumping states as no suction or suction. The in-silico results using a combined human circulatory system and LVAD model show that the proposed method can detect ventricular suction effectively, demonstrating that it has high classification accuracy, stability, and robustness. The proposed suction detection system could be an important part in the LVAD for detecting and avoiding suction, while at the same time making the LVAD meet the cardiac output demand for the patients. It could also provide theoretical basis and technology support for designing and optimizing the control system of the LVAD.

          Release date:2019-06-17 04:41 Export PDF Favorites Scan
        • Value of transthoracic echocardiography to monitor and evaluate aortic insufficiency after implantation of left ventricular assist device

          ObjectiveTo explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD).MethodsWe retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation.ResultsAll 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05).ConclusionTTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.

          Release date:2021-07-02 05:22 Export PDF Favorites Scan
        • Research on Control of the Cardiovascular System Based on a Left Ventricular Assist Device

          We propose a control model of the cardiovascular system coupled with a rotary blood pump in the present paper. A new mathematical model of the rotary heart pump is presented considering the hydraulic characteristics and the similarity principle of pumps. A seven-order nonlinear spatial state equation adopting lumped parameter is used to describe the combined cardiovascular-pump model. Pump speed is used as the control variable. To achieve sufficient perfusion and to avoid suction, a feedback strategy based on minimum (diastolic) pump flow is used in the control model. The results showed that left ventricular assist device (LVAD) could improve hemodynamics of the cardiovascular system of the patient with heart failure in open loop. When rotation speed was 9,000 r/min, cardiac output reached 82 mL/s while the initial cardiac output was only 34 mL/s without the LVAD support. When the rotation speed was above 12 800 r/min, suction was found because the high rotating speed resulted in insufficient venous return volume. Suction was avoided by adopting the feedback control. The model reveals the interaction of LVAD and the cardiovascular system, which provides theoretical basis for the therapy of heart failure in the left ventricular and for the design of a physiological control strategy.

          Release date:2016-12-19 11:20 Export PDF Favorites Scan
        • Study on the synchronization of biventricular beats with the control mode of left ventricular assist device

          Right ventricular (RV) failure has become a deadly complication of left ventricular assist device (LVAD) implantation, for which desynchrony in bi-ventricular pulse resulting from a LVAD is among the important factor. This paper investigated how different control modes affect the synchronization of pulse between LV (left ventricular) and RV by numerical method. The numerical results showed that the systolic duration between LV and RV did not significantly differ at baseline (LVAD off and cannula clamped) (48.52% vs. 51.77%, respectively). The systolic period was significantly shorter than the RV systolic period in the continuous-flow mode (LV vs. RV: 24.38% vs. 49.16%) and the LV systolic period at baseline. The LV systolic duration was significantly shorter than the RV systolic duration in the pulse mode (LV vs. RV: 28.38% vs. 50.41%), but longer than the LV systolic duration in the continuous-flow mode. There was no significant difference between the LV and RV systolic periods in the counter-pulse mode (LV vs. RV: 43.13% vs. 49.23%). However, the LV systolic periods was shorter than the no-pump mode and much longer than the continuous-flow mode. Compared with continuous-flow and pulse mode, the reduction in rotational speed (RS) brought out by counter-pulse mode significantly corrected the duration of LV systolic phase. The shortened duration of systolic phase in the continuous-flow mode was corrected as re-synchronization in the counter-pulse mode between LV and RV. Hence, we postulated that the beneficial effects on RV function were due to re-synchronizing of RV and LV contraction. In conclusion, decreased RS delivered during the systolic phase using the counter-pulse mode holds promise for the clinical correction of desynchrony in bi-ventricular pulse resulting from a LVAD and confers a benefit on RV function.

          Release date:2021-04-21 04:23 Export PDF Favorites Scan
        • The progress of mechanical circulatory support devices

          As a global disease, heart failure affects at least 26 million people, and its prevalence is still rising. Besides, the mortality rate and readmission rate remain high. Advanced heart failure is the terminal stage of various heart diseases, and often requires some treatments other than drug intervention, such as heart transplantation which is the gold standard for treatment of heart failure. However, limited by the number of donors, the number of heart transplants in the world has reached a bottleneck. There is a huge gap between the number of patients who need heart transplants and patients who get hearts for survival successfully in reality. With the exploration and development of mechanical circulation support devices for more than half a century, they have become a wonderful treatment for patients with advanced heart failure. This article will introduce the latest progress of mechanical circulatory support devices at home and abroad from the aspects of temporary and long-term devices.

          Release date:2023-08-31 05:57 Export PDF Favorites Scan
        3 pages Previous 1 2 3 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品