Objective To review the research progress of exosomes (EXOs) derived from different cells in the treatment of osteoporosis (OP). Methods Recent relevant literature about EXOs for OP therapy was extensively reviewed. And the related mechanism and clinical application prospect of EXOs derived from different cells in OP therapy were summarized and analyzed. Results EXOs derived from various cells, including bone marrow mesenchymal stem cells, osteoblasts, osteoclasts, osteocytes, and endothelial cells, et al, can participate in many links in the process of bone remodeling, and their mechanisms involve the regulation of proliferation and differentiation of bone-related cells, the promotion of vascular regeneration and immune regulation, and the suppression of inflammatory reactions. A variety of bioactive substances contained in EXOs are the basis of regulating the process of bone remodeling, and the combination of genetic engineering technology and EXOs-based drug delivery can further improve the therapeutic effect of OP. Conclusion EXOs derived from different cells have great therapeutic effects on OP, and have the advantages of low immunogenicity, high stability, strong targeting ability, and easy storage. EXOs has broad clinical application prospects and is expected to become a new strategy for OP treatment.
ObjectiveTo explore the nature of micromovement and the biomechanical staging of fracture healing.MethodsThrough literature review and theoretical analysis, the difference in micromovement research was taken as the breakthrough point to try to provide a new understanding of the role of micromovement and the mechanical working mode in the process of fracture healing.ResultsThe process of fracture healing is the process of callus generation and connection. The micromovement is the key to start the growth of callus, and the total amount of callus should be matched with the size of the fracture space. The strain at the fracture end is the key to determine the callus connection. The strain that can be tolerated by different tissues in the fracture healing process will limit the micromovement. According to this, the fracture healing process can be divided into the initiation period, perfusion period, contradiction period, connection period, and physiological period, i.e., the biomechanical staging of fracture healing.ConclusionBiomechanical staging of fracture healing incorporates important mechanical parameters affecting fracture healing and introduces the concepts of time and space, which helps to understand the role of biomechanics, and its significance needs further clinical test and exploration.
Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.
ObjectiveTo understand the location characteristics of the lumbosacral autonomic nerve plexus and the morphological changes so as to provide the anatomic theoretical basis for the protection of autonomic nerve during the lower lumbar anterior approach operation.
MethodsA random anatomic investigation was carried out on 19 formalin-treated adult cadavers (15 males and 4 females; aged 44-78 years, mean 64 years). The anterior median line (connection of suprasternal fossa point and the midpoint of the symphysis pubis) was determined, and the characteristics of abdominal aortic plexus (AAP), inferior mesenteric plexus (IMP), and superior hypogastric plexus (SHP) were observed. The relationship between the autonomic nerve and the anterior median line was measured and recorded.
ResultsAPP and IMP were found to be located chiefly in front of the abdominal aorta in a reticular pattern, and the nerve fibers of the two nerve plexuses were more densely at the left side of abdominal aorta than at the right side. Superior hypogastric plexus showed more distinct main vessel variations, including 4 types. The main vessel length of the SHP was (59.38±12.86) mm, and the width was (11.25±2.92) mm. The main vessels of SHP were mainly located at the left side of the ventral median line (10, 52.6%) and anterior lumbar vertebra (13, 68.4%). The main vessels extended down to form the left and right hypogastric nerves.
ConclusionIt is applicable to expose the nerve from the right side of centrum and move the autonomic nerve and blood vessel as a whole during anterior lower lumbar operation. In this way, the dissection to separate nerve plexus is not needed, thus nerve injury can be avoided to the largest extent.
Objective To investigate the effect of ultrasonic bone curette in anterior cervical spine surgery. MethodsA clinical data of 63 patients with cervical spondylosis who were admitted between September 2019 and June 2021 and met the selection criteria was retrospectively analyzed. Among them, 32 cases were operated with conventional instruments (group A) and 31 cases with ultrasonic bone curette (group B). There was no significant difference between the two groups (P>0.05) in gender, age, surgical procedure, surgical segment and number of occupied cervical space, disease type and duration, comorbidities, and preoperative Japanese Orthopaedic Association (JOA) score, cervical dysfunction index (NDI), and pain visual analogue scale (VAS) score. The operation time, intraoperative bleeding, postoperative drainage, postoperative hospital stay, and the occurrence of postoperative complications were recorded in both groups. Before operation and at 1, 3, and 6 months after operation, the JOA score and NDI were used to evaluate the function and the postoperative JOA improvement rate was calculated, and VAS score was used to evaluate the pain improvement. The anteroposterior and lateral cervical X-ray films were taken at 1, 3, and 6 months after operation to observe whether there was any significant loosening and displacement of internal fixators. ResultsCompared with group A, group B had shorter operation time and postoperative hospital stay, less intraoperative bleeding and postoperative drainage, and the differences were significant (P<0.05). All incisions healed by first intention in the two groups, and postoperative complications occurred in 5 cases (15.6%) in group A and 2 cases (6.5%) in group B, showing no significant difference (P>0.05). All patients were followed up 6-12 months (mean, 7.9 months). The JOA score and improvement rate gradually increased in groups A and B after operation, while the VAS score and NDI gradually decreased. There was no significant difference in VAS score between 3 months and 1 month in group B (P>0.05), and there were significant differences between the other time points of each indicator in the two groups (P<0.05). At 1, 3, and 6 months after operation, the JOA score and improvement rate in group B were better than those in group A (P<0.05). X-ray films examination showed that there was no screw loosening or titanium plate displacement in the two groups after operation, and the intervertebral cage or titanium mesh significantly sank. ConclusionCompared with traditional instruments, the use of ultrasonic bone curette assisted osteotomy in anterior cervical spine surgery has the advantages of shorter operation time, less intraoperative bleeding, less postoperative drainage, and shorter hospital stay.
ObjectiveTo explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures. Methods A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome. Results The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation (P<0.05). And there was no significant difference between immediately after operation and last follow-up (P>0.05). Conclusion The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
ObjectiveTo assess the long-term effectiveness of the transplantation of iliac bone flap pedicled with deep iliac circumflex vessels for treating avascular necrosis of femoral head (ANFH) at Ficat stage Ⅱ and Ⅲ.
MethodsThirty-two cases (43 hips) of ANFH underwent iliac bone flap transplantation pedicled with deep iliac circumflex vessels between October 2000 and February 2006, and the clinical data were retrospectively reviewed. Of 32 cases, 27 were male (38 hips), and 5 were female (5 hips), aged 21-52 years (mean, 36.6 years); there were 8 cases (11 hips) of hormone ANFH, 18 cases (23 hips) of alcoholic ANFH, and 6 cases (9 hips) of idiopathic ANFH. The disease duration ranged from 2-52 months (mean, 8.2 months). According to Ficat staging criteria, 26 hips were classified as stage Ⅱ and 17 hips as stage Ⅲ. The preoperative Harris hip score (HSS) was 68.2±8.4. The HHS scores and X-ray photograph were compared between at pre-and post-operation to assess the outcomes clinically and radiologically.
ResultsAll incisions healed by first intention. Two cases had numbness of the lateral femoral skin. Four patients (6 hips) failed to be followed up, and the other 28 cases were followed up 98-187 months (mean, 129.3 months). Five patients (6 hips) showed aggravation or no relief with progression to stage Ⅳ at 8-69 months, who received total hip arthroplasty. The 10-year survival rate was 83.78% (31/37). The HHS score was significantly increased to 86.7±9.0 at last follow-up (t=-48.313, P=0.000). The hip function was excellent in 9 hips, good in 13 hips, and fair in 9 hips, and the success rate was 75.68%. Radiographic examination showed signs of bone remodeling at 6-8 weeks. After bone healing, the femoral head density gradually became uniform. Until last follow-up, ANFH progressed from Ficat stage Ⅱ to Ⅲ in 5 hips, from Ficat stage Ⅱ to Ⅳ in 3 hips, and from Ficat stage Ⅲ to Ⅳ in 3 hips; complete hip shape, continuous Shenton line, and normal joint space were observed in the other 26 hips, and the radiographic success rate was 70.27% (26/37).
ConclusionThe pedicled iliac bone flap transplantation for ANFH at Ficat stage Ⅱ and Ⅲ can provide good osteogenesis and vascular reconstruction of the femoral head. The long-term follow-up effectiveness is satisfactory.
Objective To investigate short-term effectiveness of robot-guided femoral neck system (FNS) combined with cannulated compression screw (CCS) fixation in treatment of femoral neck fracture in young and middle-aged patients. Methods A clinical data of 49 young and middle-aged patients with femoral neck fractures, who met the selection criteria and admitted between January 2021 and June 2023, was retrospectively analyzed. After reduction of femoral neck fractures, 27 cases were treated with robot-guided FNS fixation (FNS group) and 22 cases with robot-guided FNS and CCS fixation (FNS+CCS group). There was no significant difference in baseline data such as gender, age, cause of fracture, time from fracture to operation, fracture side, and classification (Garden classification and Pauwels classification) between the two groups (P>0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, the time when the patient began bearing weight, and hip joint pain and functional scores (VAS score and Harris score) at last follow-up for two groups were recorded. Imaging re-examination was taken to evaluate the quality of fracture reduction, fracture healing, as well as the occurrence of fracture non-union, osteonecrosis of the femoral head, and femoral neck shortening. Results All operations were successfully completed and the incisions healed by first intention. There was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05), and the intraoperative fluoroscopy frequency in FNS+CCS group significantly increased compared to FNS group (P<0.05). All patients were followed up 12-18 months (mean, 14.1 months). Imaging re-examination showed that there was no significant difference in fracture reduction quality between the two groups (P>0.05), but the fracture healing time was significantly shorter in FNS+CCS group than in FNS group, and weight-bearing began earlier (P<0.05). The incidences of femoral neck shortening, fracture non-union, and osteonecrosis of the femoral head were lower in FNS+CCS group than in FNS group, and there was significant difference in the incidence of femoral neck shortening between groups (P<0.05). At last follow-up, there was no significant difference in VAS scores between the two groups (P>0.05). However, the Harris score was significantly higher in FNS+CCS group than in FNS group (P<0.05). ConclusionCompared with FNS fixation alone, robot-guided FNS combined with CCS fixation in the treatment of femoral neck fractures in young and middle-aged patients has obvious advantages in terms of early weight bearing and fracture healing, improves fracture healing rate, effectively prevents postoperative complications, and can obtain good short-term effectiveness.
ObjectiveTo compare the clinical and radiologic effectiveness in patients with versus without lateral hinge fracture during medial opening-wedge high tibial osteotomy (MOWHTO) to evaluate the effect of lateral hinge fracture on short-term effectiveness.MethodsThe clinical data of 84 patients (97 knees) with medial compartment osteoarthritis who treated with MOWHTO between September 2015 and July 2018 was retrospectively analyzed. There were 10 males (10 knees) and 74 females (87 knees). The age ranged from 45 to 65 years with an average of 57.7 years. Lateral hinge fracture was recognized by the intraoperative fluoroscopy or immediate postoperative X-ray film. Fractures were classified into types Ⅰ, Ⅱ, and Ⅲ according to the Takeuchi classification. The healing of osteotomy was observed by radiographs during follow-up; the femur tibia angle (FTA), medialproximal tibial angle (MPTA), and hip-knee-ankle angle (HKA) were also calculated. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score and knee society score (KSS).ResultsThe incision healed by first intention. All patients were followed up 15-48 months with an average of 24.8 months. No hinge fracture occurred in 78 knees (80.41%, group A), and lateral hinge fractures were observed in 19 knees (19.59%, group B) and were divided into the type Ⅰ (13 knees, 13.40%) and type Ⅲ (6 knees, 6.19%) groups. Type Ⅰ fractures were not additionally treated, type Ⅲ fractures were anatomic reduced fixed with additional lag screws. X-ray film and CT examination showed that all patients had bone healing at 3 months after operation without delayed healing or nonunion. During follow-up, there was no loosening or fracture of internal fixation plates and screws. HKA, FTA, and MPTA of patients in group A and group B (type Ⅰ and Ⅲ) were significantly improved at each time point after operation compared with preoperative values (P<0.05); there was no significant difference between groups at each time point before and after operation (P>0.05). After operation, the pain of knee joint was alleviated and the function of joint was improved. At last follow-up, KSS score and HSS score of groups A and B were significantly improved compared with those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05).ConclusionThe lateral hinge fracture may occur during MOWHTO. As long as the treatment and rehabilitation were guided according to the fracture classification of the hinge, the effectiveness can be similar to those without the hinge fracture.