Objective
To summarize the visual outcome of patients with severe ocular trauma treated with vitreous surgery.
Methods
Clinical data of 188(191 eyes) with severe ocular trauma treated with vitreous surgery in a period from November 1996 to April 1998 were analysed retrospectively.
Results
The study included penetrating injury in 56 eyes, foreign bodies in the posterior segment in 70 eyes, blunt injury in 41 eyes , and globe rupture in 24 eyes. Main complications included endophthalmitis in 35 eyes, choroidal bleeding in 20 eyes, retinal detachment in 60 eyes, and vitreous hemorrhage in 97 eyes. Post-opera-tively, out of 188 eyes, except for 3 of patients too young to examine, visual acuity improved in 133(70.7%), including 85(45.2%) with visal acuity 0.02-1.0, 46(24.5%) remained unchanged; and 9(4.8%) had worse vision. Among 34 with no-light-perception, 12 had light-perception or over.
Conclusion
A majority of severe trauma eyes can be salvaged with considerable visual recovery after adequate and timely vitreous surgery.
(Chin J Ocul Fundus Dis,1999,15:4-6)
Objective To summarize the experience of open heart operation on neonates with critical and complex congenital heart diseases and evaluate the methods of perioperative management. Methods From May 2001 to January 2003, 12 patients of neonates with congenital heart diseases underwent emergency operation. Their operating ages ranged from 6 to 30 days, the body weights were 2.8 to 4.5 kg. Their diagnoses included D-transposition of the great arteries in 4 cases, ventricular septal defect with atrial septal defect in 5 cases, complete atrioventricular septal defect, obstructed supracardiac total anomalous pulmonary venous drainage and cardiac rhabdomyomas in 1 case respectively. 12 cases were operated under moderate or deep hypothermic cardiopulmonary bypass. Results All cases were observed in ICU for 2-11 days and discharged 7-19 days after operation. The postoperative complications included low cardiac output, mediastinal infection, respiratory distress syndrome, systemic capillary leak syndrome and acute renal failure. All cases were cured and the follow-up (from 6 months to 2 years) showed satisfactory outcome. Conclusion A particular cardiopulmonary bypass and proper perioperative management is very important to ensure the successful outcome. Peritoneal dialysis is an effective and safe method for treating acute renal failure after cardiac operation in neonates.
Objective To understand the latest research developments of the formation mechanism of psammoma body in human tumors and related issues. Methods Related domestic and foreign literatures were widely referred, analyzed, and reviewed. Results Psammoma body is unique pathological calcification in some tumors, which is arranged in concentric, laminar circles microscopically. Psammoma body is commonly seen in thyroid papillary carcinoma, meningiomas, ovarian serous papillary carcinoma, and so on. Conclusions Although arranged in concentric, laminar circles microscopically in tumor, the formation process of psammoma body is not entirely the same in different tumors. A comprehensive and objective understanding of psammoma body would be useful in cancer diagnosis and treatment.
This study reports the first successful clinical application of a robotic-assisted system in transcatheter balloon-expandable aortic valve implantation using the Edwards SAPIEN 3 valve. Two male patients, aged 60 and 63 years, respectively, presented with severe aortic stenosis confirmed by echocardiography and computed tomography, showing significant valvular calcification and elevated transvalvular pressure gradients, meeting the indications for transcatheter aortic valve implantation (TAVI). Both procedures were performed via the right femoral artery using a robotic-assisted delivery and positioning system developed by Shanghai Surgerii Medical Technology Co., Ltd. The operator controlled the delivery system and valve positioning precisely through the console, while the assistant performed balloon expansion and valve deployment. Both procedures were completed successfully without intraoperative complications. The operative times were 75 minutes and 67 minutes, with fluoroscopy times of 16 minutes and 23 minutes, and radiation doses of 714 mGy and 971 mGy, respectively. Postoperative echocardiography demonstrated well-functioning prosthetic valves, with mean transvalvular pressure gradients of 3.9 mm Hg and 8.0 mm Hg, and none or trivial paravalvular leakage. No coronary obstruction, conduction disturbance, or vascular complications were observed. This report represents the world’s first clinical use of a robotic-assisted system for balloon-expandable TAVI. It confirms the feasibility and safety of robotic assistance in transcatheter valve delivery and positioning, offering a new approach to enhance procedural precision and stability, and providing valuable insights for the future development of intelligent, minimally invasive therapies for structural heart disease.