ObjectiveTo discuss the operation skill and clinical effects of using domestic balloon-expandable Prizvalve? transcatheter "valve-in-valve" to treat the degenerated bioprosthesis in the tricuspid position.MethodsAll the admitted surgical tricuspid valve bioprosthetic valve replacement patients were evaluated by computerized tomography angiography (CTA), ultrasound, and 3D printing technology, and 2 patients with a degenerated bioprosthesis were selected for tricuspid valve "valve-in-valve" operation. Under general anesthesia, the retro-preset Prizvalve? system was implanted into degenerated tricuspid bioprosthesis via the femoral vein approach under the guidance of transesophageal echocardiographic and fluoroscopic guidance.ResultsTranscatheter tricuspid valve implantation was successfully performed in both high-risk patients, and tricuspid regurgitation disappeared immediately. The operation time was 1.25 h and 2.43 h, respectively. There was no serious complication in both patients, and they were discharged from the hospital 7 days after the operation.ConclusionThe clinical effect of the degenerated tricuspid bioprosthetic valve implantation with domestic balloon-expandable valve via femoral vein approach "valve-in-valve" is good. Multimodality imaging and 3D printing technology can safely and effectively guide the implementation of this innovative technique.
ObjectiveTo evaluate the effectiveness of three-dimensional (3D) printing artificial vertebral body and interbody fusion Cage in anterior cervical disectomy and fusion (ACCF) combined with anterior cervical corpectomy and fusion (ACDF).MethodsThe clinical data of 29 patients with multilevel cervical spondylotic myelopathy who underwent ACCF combined with ACDF between May 2018 and December 2019 were retrospectively analyzed. Among them, 13 patients were treated with 3D printing artificial vertebral body and 3D printing Cage as 3D printing group and 16 patients with ordinary titanium mesh Cage (TMC) and Cage as TMC group. There was no significant difference in gender, age, surgical segment, Nurick grade, disease duration, and preoperative Japanese Orthopaedic Association (JOA) score, visual analogue scale (VAS) score, and Cobb angle of fusion segment between the two groups (P>0.05). The operation time, intraoperative blood loss, hospitalization stay, complications, and implant fusion at last follow-up were recorded and compared between the two groups; JOA score was used to evaluate neurological function before operation, immediately after operation, at 6 months after operation, and at last follow-up; VAS score was used to evaluate upper limb and neck pain. Cobb angle of fusion segment was measured and the difference between the last follow-up and the immediate after operation was calculated. The height of the anterior border (HAB) and the height of the posterior border (HPB) were measured immediately after operation, at 6 months after operation, and at last follow-up, and the subsidence of implant was calculated.ResultsThe operation time of 3D printing group was significantly less than that of TMC group (t=3.336, P=0.002); there was no significant difference in hospitalization stay and intraoperative blood loss between the two groups (P>0.05). All patients were followed up 12-19 months (mean, 16 months). There was no obvious complication in both groups. There were significant differences in JOA score, VAS score, and Cobb angle at each time point between the two groups (P<0.05). There was an interaction between time and group in the JOA score (F=3.705, P=0.025). With time, the increase in JOA score was different between the 3D printing group and the TMC group, and the increase in the 3D printing group was greater. There was no interaction between time and group in the VAS score (F=3.038, P=0.065), and there was no significant difference in the score at each time point between the two groups (F=0.173, P=0.681). The time of the Cobb angle interacted with the group (F=15.581, P=0.000). With time, the Cobb angle of the 3D printing group and the TMC group changed differently. Among them, the 3D printing group increased more and the TMC group decreased more. At last follow-up, there was no significant difference in the improvement rate of JOA score between the two groups (t=0.681, P=0.502), but the Cobb angle difference of the 3D printing group was significantly smaller than that of the TMC group (t=5.754, P=0.000). At last follow-up, the implant fusion rate of the 3D printing group and TMC group were 92.3% (12/13) and 87.5% (14/16), respectively, and the difference was not significant (P=1.000). The incidence of implant settlement in the 3D printing group and TMC group at 6 months after operation was 15.4% (2/13) and 18.8% (3/16), respectively, and at last follow-up were 30.8% (4/13) and 56.3% (9/16), respectively, the differences were not significant (P=1.000; P=0.264). The difference of HAB and the difference of HPB in the 3D printing group at 6 months after operation and last follow-up were significantly lower than those in the TMC group (P<0.05).ConclusionFor patients with multilevel cervical spondylotic myelopathy undergoing ACCF combined with ACDF, compared with TMC and Cage, 3D printing artificial vertebrae body and 3D printing Cage have the advantages of shorter operation time, better reduction of height loss of fusion vertebral body, and maintenance of cervical physiological curvature, the early effectiveness is better.
More and more relevant research results show that anatomical segmentectomy has the same effect as traditional lobectomy in the surgical treatment of early-stage non-small cell lung cancer (diameter<2.0 cm). Segmentectomy is more difficult than lobotomy. Nowadays, with the promotion of personalization medicine and precision medicine, three-dimensional technique has been widely applied in the medical field. It has advantages such as preoperative simulation, intraoperative positioning, intraoperative navigation, clinical teaching and so on. It plays a key role in the discovery of local anatomical variation of pulmonary segment. This paper reviewed the clinical application of three-dimensional technique and briefly described the clinical application value of this technique in segmentectomy.
ObjectiveTo investigate the clinical application of three-dimensional (3D) printing technique combined with a new type of thoracic pedicle screw track detector in thoracic pedicle screw placement.MethodsAccording to the characteristics of thoracic pedicle and common clinical screw placement methods, a new type of thoracic pedicle screw track detector was independently developed and designed. The clinical data of 30 patients with thoracic vertebrae related diseases who underwent posterior thoracic pedicle screw fixation between March 2017 and January 2020 were retrospectively analysed. Among them, there were 18 males and 12 females with an average age of 56.3 years (range, 32-76 years). There was 1 case of thoracic disc herniation, 4 cases of thoracic canal stenosis, 2 cases of ossification of posterior longitudinal ligament of thoracic vertebra, 16 cases of thoracic trauma, 2 cases of thoracic infection, and 5 cases of thoracic canal occupation. Three-dimensional CT of the thoracic vertebra was routinely performed preoperatively, and the model of the patient’s thoracic vertebra was reconstructed and printed out. With the assistance of the model, preoperative simulation was performed with the combination of the new type thoracic pedicle screw track detector, and detected no nails after critical cortical damage. During operation, one side was randomly selected to use traditional hand screws placement (control group), and the other side was selected to use 3D printing technique combined with new type thoracic pedicle screw track detector to assist thoracic pedicle screws placement (observation group). The single screw placement time, adjustment times of single screw, and blood loss during screw placement were compared between the two groups. The accuracy of screw placement in the two groups was evaluated according to postoperative CT imaging data.ResultsThe single screw placement time, adjustment times of single screw, and blood loss during screw placement in the observation group were significantly less than those in the control group (P<0.05). Postoperative CT examination showed that the observation group had 87 screws of grade 1, 3 screws of grade 2, and the acceptable screw placement rate was 100% (90/90); the control group had 76 screws of grade 1, 2 screws of grade 2, 11 screws of grade 3, and 1 screw of grade 4, and the acceptable screw placement rate was 86.7% (78/90); showing significant difference in screw placement between the two groups (χ2=12.875, P=0.001). All patients were followed up 6-18 months, with an average of 11.3 months. There was no complication of vascular, nerve, spinal cord, or visceral injury, and screws or rods broken, and no patient was revised.ConclusionThe 3D printing technique combined with the new type of thoracic pedicle screw track detector assisted thoracic pedicle screw placement is convenient, and significantly improves the accuracy and safety of intraoperative screw placement, and overall success rate of the surgery.
ObjectiveTo summarize the research progress of tissue engineering technology to promote bone tissue revascularization in osteonecrosis of the femoral head (ONFH).MethodsThe relevant domestic and foreign literature in recent years was extensively reviewed. The mechanism of femoral head vascularization and the application progress of tissue engineering technology in the promotion of ONFH bone tissue revascularization were summarized.ResultsRebuilding or improving the blood supply of the femoral head is the key to the treatment of ONFH. Tissue engineering is a hot spot in current research. It mainly focuses on the three elements of seed cells, scaffold materials, and angiogenic growth factors, combined with three-dimensional printing technology and drug delivery systems to promote the revascularization of the femoral bone tissue.ConclusionThe strategy of revascularization of the femoral head can improve the local blood supply and delay or even reverse the progression of ONFH disease.
Objective
To evaluate the effectiveness of total knee arthroplasty (TKA) using three-dimensional (3D) printing technology for knee osteoarthritis (KOA) accompanied with extra-articular deformity.
Methods
Between March 2013 and December 2015, 15 patients (18 knees) with extra-articular deformity and KOA underwent TKA. There were 6 males (6 knees) and 9 females (12 knees), aged 55-70 years (mean, 60.2 years). The mean disease duration was 10.8 years (range, 7-15 years). The unilateral knee was involved in 12 cases and bilateral knees in 3 cases. The clinical score was 57.44±1.06 and the functional score was 60.88±1.26 of Knee Society Score (KSS). The range of motion of the knee joint was (72.22±0.18)°. The deviation of mechanical axis of lower limb was (18.89±0.92)° preoperatively. There were 8 cases (10 knees) with extra-articular femoral deformity, 5 cases (5 knees) with extra-articular tibial deformity, and 2 cases (3 knees) with extra-articular femoral and tibial deformities. Bone models and the navigation templates were printed and the operation plans were designed using 3D printing technology. The right knee joint prostheses were chosen.
Results
The operation time was 65-100 minutes (mean, 75.6 minutes). The bleeding volume was 50-150 mL (mean, 90.2 mL). There was no poor incision healing, infection, or deep venous thrombosis after operation. All patients were followed up 12- 30 months (mean, 22 months). Prostheses were located in the right place, and no sign of loosening or subsidence was observed by X-ray examination. At last follow-up, the deviation of mechanical axis of lower limb was (2.00±0.29)°, showing significant difference when compared with preoperative one (t=13.120, P=0.007). The KSS clinical score was 87.50±0.88 and function score was 81.94±1.41, showing significant differences when compared with preoperative ones (t=27.553, P=0.000; t=35.551, P=0.000). The range of motion of knee was (101.94±1.42)°, showing significant difference when compared with preoperative one (t=31.633, P=0.000).
Conclusion
For KOA accompanied with extra-articular deformity, TKA using 3D printing technology has advantages such as individualized treatment, reducing the difficulty of operation, and achieving the satisfactory function.
Objective To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. Methods The L1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. Results A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared with preoperative ones (t=14.842,P=0.006;t=36.927,P=0.002;t=–36.031,P=0.001). Thirty-one patients were followed up 8-24 months (mean, 18.7 months). All incision healed by first intention, and no complication occurred. During the follow-up, X-ray film and CT showed that pedicle screw was accurately placed without loosening or breakage, and with good fusion of intervertebral bone graft. Conclusion 3D-printing navigational templates in Quadrant minimally invasive system can help lumbar surgery gain minimal invasion, less radiation, and accurate placement.
Objective
To review the application progress of digital technology in auricle reconstruction.
Methods
The recently published literature concerning the application of digital technology in auricle reconstruction was extensively consulted, the main technology and its specific application areas were reviewed.
Results
Application of digital technology represented by three-dimensional (3D) data acquisition, 3D reconstruction, and 3D printing is an important developing trend of auricle reconstruction. It can precisely guide auricle reconstruction through fabricating digital ear model, auricular guide plate, and costal cartilage imaging.
Conclusion
Digital technology can improve effectiveness and decrease surgical trauma in auricle reconstruction. 3D bioprinting of ear cartilage future has bright prospect and needs to be further researched.
ObjectiveTo explore the feasibility of lumbar puncture models based on 3D printing technology for training junior orthopaedic surgeons to find the optimal pedicle screw insertion points.MethodsMimics software was used to design 3D models of lumbar spine with the optimal channels and alternative channels. Then, the printed lumbar spine models, plasticine, and cloth were used to build lumbar puncture models. From January 2018 to June 2019, 43 orthopedic trainees performed simulated operations to search for the insertion points of pedicle screws base on the models. The operations were performed once a day for 10 consecutive days, and the differences in operation scores and operation durations of the trainees among the 10 days were compared.ResultsAll the trainees completed the surgical training operations successfully, and there were significant differences in the operation scores (13.05±2.45, 14.02±3.96, 17.58±3.46, 21.02±2.04, 23.40±4.08, 25.14±3.72, 27.26±6.09, 33.37±4.23, 35.00±4.15, 38.49±1.70; F=340.604, P<0.001) and operation durations [(22.51±4.28), (19.93±4.28), (18.05±2.89), (17.05±1.76), (16.98±1.97), (15.47±1.74), (13.51±1.42), (12.60±2.17), (12.44±1.71), (11.91±1.87) minutes; F=102.359, P<0.001] among the 10 days.ConclusionThe 3D models of lumbar puncture are feasible and repeatable, which can contribute to surgical training.