ObjectiveTo investigate the efficacy of vagus nerve stimulation (VNS) in patients with refractory magnetic resonance imaging (MRI)-negative epilepsy and to evaluate potential clinical predictors. MethodsA retrospective collection of efficacy data was conducted on 24 patients with intractable MRI-negative epilepsy treated with VNS, who were followed up for more than six months, at Beijing Tiantan Hospital and Beijing Fengtai Hospital from January 2016 to September 2023. Patients were divided into two subgroups based on their response to VNS: responders (≥50% reduction in seizure frequency) and non-responders (<50% reduction in seizure frequency). The relationship between preoperative clinical data and VNS efficacy was further analyzed to identify potential predictors of VNS efficacy. ResultsA total of 24 patients were included, with an average age of (14.26±8.39) years old. Seizure frequency was reduced by more than 50% in 37.5% of patients, and 8.3% of patients achieved seizure-free after VNS treatment. Preoperative seizure frequency and interictal epileptiform discharge type were significantly associated with VNS efficacy (P<0.05). Multivariate regression analysis showed that a monthly seizure frequency of less than 100 and focal interictal epileptiform discharges were independent predictors of VNS efficacy (P<0.05). ConclusionVNS is an effective treatment for patients with refractory MRI-negative epilepsy. Lower monthly seizure frequency and focal interictal epileptiform discharges are potential predictors of VNS efficacy. These findings provide important references for clinicians in selecting and evaluating patients for VNS treatment.
Objective
To review the research progress of the role of periosteum in distraction osteogenesis.
Methods
The related domestic and foreign literature about the role of periosteum in distraction osteogenesis in recent years was extensively reviewed, summarized, and the mechanism and influencing factors of periosteum during traction and osteogenesis were analyzed.
Results
The periosteum is rich in all kinds of cells (mesenchymal stem cells, osteoblasts, etc.), microvessel and various growth factors, which are necessary for the formation of new bone. It can promote the formation of new bone in the process of traction osteogenesis significantly.
Conclusion
The periosteum plays an important role in the progress of distraction osteogenesis.
Objective To explore the effectiveness of folded transverse superficial epigastric artery perforator flap in repairing the large penetrating defect after buccal carcinoma resection. Methods Between January 2019 and June 2021, 12 patients with buccal squamous cell carcinoma were treated. There were 6 males and 6 females with an average of 66.9 years (range, 53-79 years). The pathological stage was T3a-T4b, and the preoperative mouth opening was (3.08±0.46) cm. The disease duration ranged from 6 to 24 months, with an average of 15 months. After buccal carcinoma radical resection and neck lymph node dissection, the penetrating defects in size of 8 cm×6 cm to 16 cm×8 cm and in depth of 0.5-1.5 cm were remained. The transverse superficial epigastric artery perforator flap in size of 8 cm×6 cm to 14 cm×8 cm were harvested and folded to repair the penetrating defects. The donor site was sutured directly. Results All 12 skin flaps survived after operation, and the wounds healed by first intention. No internal or external fistula complications occurred. All incisions at the recipient site healed by first intention. All patients were followed up 12-18 months (mean, 14 months). There was no obvious abnormality in the color and texture of the flap, the oral and facial appearances were symmetrical, and there was no obvious swelling in the cheek. At last follow-up, the patient’s mouth opening was (2.89±0.33) cm, which was not significantly different from that before operation (t=1.879, P=0.087). The subjective satisfaction scores of 12 patients were 6-8 points, with an average of 7.3 points. Significant scars remained at the donor site but concealed in location. Conclusion The folded transverse superficial epigastric artery perforator flap can be used as a surgical method for repairing large penetrating defects after the buccal carcinoma resection, with a good recovery of facial appearance and oral function.
Objective To provide the anatomical basis for the appl ication of the superficial inferior epigastric artery flap. Methods Ten cadavers which were immersed in formal in less than 6 months and were perfused by red latex were used in this study. There were 8 males and 2 females with an average age of 58 years (range, 35-78 years). The origin, course, branch,distribution, diameter, pedicle length, and neighbour of superficial inferior epigastric artery and vein were observed in the 2 sides of inguinal region. Results In these series of 10 cadaver (20 sides) dissections, the superficial inferior epigastric artery was identified in 18 sides, which average cal iber was 1.48 mm with a mean vascular pedicle length of 4.80 cm. In 11 sides, the superficial inferior epigastric artery arose aspart of a common trunk with one or more other vessels; in other 7, it originated from the femoral. There were 4 branch modes of superficial inperior epigastric artery: single trunks (5 sides), double ramification (3 sides), single lateral ramification (7 sides), and single medial ramification (3 sides). The superficial inferior epigastric vein was observed in 20 sides, which average cal iber was 2.33 mm with a mean sides pedicle length of 5.45 cm. In 8 sides, the venous drainage was as an individual vein; in 12 sides, both patterns were observed (a pair of venae comitantes and an individual vein). Conclusion The inferior epigastric artery flap can be appl ied to microsurgical flap transfer, potentially in breast reconstruction, phalloplasty, reconstruction of head, neck and four l imbs defects.
With high thermal stability, excellent mechanical properties, suitable biocompatibility and radiolucency, polyaryletherketones (PAEKs) have been widely used in biomedical field such as trauma, spinal implants, craniomaxillofacial repair and so on. However, PAEKs are bio-inert in nature and often show weak osteointegration with host bone, limiting their further utilization in biomedical application. Therefore, how to improve the bioactivity and osteointegration of PAEK implants has become the focus in biomedical field. This paper reviews the current research advance and some existed problems in bioactive PAEKs, and outlooks the possible solution.
Objective To evaluate the effectiveness of free medial femoral condyle (MFC) functional chimeric perforator flap (FCPF) transplantation in reconstructing joint function by repairing concomitant osteochondral defects and soft tissue defect in hand and foot joints. Methods A retrospective analysis was performed on 6 patients (5 males, 1 female; mean age of 33.4 years, range 21-56 years) with traumatic osteochondral joint defects and associated tendon, nerve, and soft tissue defects treated between January 2019 and November 2024. Defect locations included metacarpal heads (n=2), metacarpophalangeal joint (n=1), first metatarsal head (n=1), base of first proximal phalanx (n=1), and talar head (n=1), with soft tissue defects in all cases. Osteochondral defect sizes ranged from 1.5 cm×1.2 cm×0.7 cm to 4.0 cm×0.6 cm×0.6 cm, and skin defects ranged from 4 cm×3 cm to 13 cm×4 cm. The stage Ⅰ treatment included debridement, antibiotic-loaded bone cement filling of bone-cartilage defects, fracture internal fixation, and coverage with vacuum sealing drainage. Stage Ⅱ involved harvesting a free MFC- FCPF included an osteochondral flap (range of 1.5 cm×1.2 cm×0.7 cm to 4.0 cm×0.6 cm×0.6 cm), gracilis and/or semitendinosus tendon grafts (length of 4-13 cm), saphenous nerve graft (length of 3.5-4.0 cm), and a perforator skin flap (range of 6 cm×4 cm to 14 cm×6 cm), each with independent vascular supply. The flap was transplanted to reconstruct joint function. Donor sites were closed primarily or with skin grafting. Flap survival was monitored postoperatively. Radiographic assessment was used to evaluate bone/joint healing. At last follow-up, the joint function recovery was assessed. Results All 6 MFC-FCPF survived completely, with primary healing of wounds and donor sites. All patients were followed up 6-44 months (mean, 23.5 months). The flaps at metacarpophalangeal joint in 1 case and at ankle joint in 1 case were treated with degreasing repair because of their bulky appearance, while the other flaps had good appearance and texture. At 3 months after operation, the visual analogue scale (VAS) score for pain during joint movement of recipient site was 0-2, with an average of 0.7; at last follow-up, the VAS score of the donor site was 0-1, with an average of 0.3. According to the Paley fracture healing scoring system, the osteochondral healing of all the 6 patients was excellent. The range of motion of the metacarpophalangeal joint in 3 cases was 75%, 90%, and 100% of contralateral side respectively, the range of motion of the metatarsophalangeal joint in 2 cases was 65% and 95% of contralateral side respectively, and the range of motion of the ankle joint in 1 case was 90% of contralateral side. The hand function was evaluated as excellent in 2 cases and good in 1 case according to the upper limb function evaluation standard of the Chinese Medical Association Hand Surgery Society, and the foot function was evaluated as excellent in 2 cases and fair in 1 case according to the Maryland foot function score of 93, 91, and 69, respectively. The International Knee Documentation Committee (IKDC) score of 6 knees was 91-99, with an average of 95.2. Conclusion The free MFC-FCPF enables precise anatomical joint reconstruction with three-dimensional restoration of tendon, nerve, capsule, and soft tissue defects, effectively restoring joint function and improving quality of life.
ObjectiveTo evaluate the clinical efficacy and safety of magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) for mesial temporal lobe epilepsy (MTLE), and to compare its outcomes with anterior temporal lobectomy (ATL). MethodsA retrospective cohort of 120 MTLE patients treated at Beijing Tiantan Hospital between August 2022 and August 2024 was analyzed, including 31 patients who underwent MRgLITT and 89 patients who underwent ATL. All patients received comprehensive presurgical evaluations, and stereoelectroencephalography (SEEG) was performed in selected cases. Clinical outcomes at 1 year were compared between the two groups, including seizure control (Engel classification, seizure reduction rate), cognitive and memory changes, quality of life, and postoperative complications. ResultsBaseline characteristics were comparable between groups. At 1-year follow-up, Engel class I outcomes were achieved in 71.0% of patients in the MRgLITT group and 67.4% in the ATL group. Seizure reduction rates were (89.6 ± 26.2)% for MRgLITT and (87.0 ± 28.7)% for ATL, with no significant difference (P=0.92). Postoperative changes in memory, cognition, and quality of life were not significantly different between groups (all P>0.05). The incidence of complications was low and similar between MRgLITT and ATL, including hemorrhage (3.2% vs. 2.2%), infection (16.1% vs. 19.1%), and neurological deficits (3.2% vs. 2.2%). ConclusionMRgLITT provides seizure control and safety outcomes comparable to ATL when applied to carefully selected MTLE patients, with the added advantages of minimal invasiveness and faster recovery. For patients with well-localized epileptogenic foci and hippocampal sclerosis, MRgLITT represents an important alternative to open resection.
Pulsed magnetic field gradients generated by gradient coils are widely used in signal location in magnetic resonance imaging (MRI). However, gradient coils can also induce eddy currents in final magnetic field in the nearby conducting structures which lead to distortion and artifact in images, misguiding clinical diagnosis. We tried in our laboratory to measure the magnetic field of gradient-induced eddy current in 1.5 T superconducting magnetic resonance imaging device; and extracted key parameters including amplitude and time constant of exponential terms according to inductance-resistance series mathematical module. These parameters of both self-induced component and crossing component are useful to design digital filters to implement pulse pre-emphasize to reshape the waveform. A measure device that is a basement equipped with phantoms and receiving coils was designed and placed in the isocenter of the magnetic field. By applying testing sequence, contrast experiments were carried out in a superconducting magnet before and after eddy current compensation. Sets of one dimension signal were obtained as raw data to calculate gradient-induced eddy currents. Curve fitting by least squares method was also done to match inductance-resistance series module. The results also illustrated that pulse pre-emphasize measurement with digital filter was correct and effective in reducing eddy current effect. Pre-emphasize waveform was developed based on system function. The usefulness of pre-emphasize measurement in reducing eddy current was confirmed and the improvement was also presented. All these are valuable for reducing artifact in magnetic resonance imaging device.
ObjectiveTo explore the effect of dynamic neuromuscular stabilization technique for chronic non-specific low back pain. MethodsFrom July 2019 to June 2020, 60 patients with chronic non-specific low back pain who underwent rehabilitation at the outpatient clinic of Sir Run Run Shaw Hospital Affiliated to Zhejiang University School of Medicine were prospectively selected. All patients were divided into trial group and control group by random number table method. There were 30 cases in each group. The control group used rehabilitation education and core muscle strength training. The trial group used dynamic neuromuscular stabilization of chest and abdomen combined with breathing control training on the basis of the treatment plan of the control group. The Visual Analogue Scale (VAS) score, Oswestry Dability Index (ODI), abdominal pressure stability, xiphoid level thoracic mobility and axillary level thoracic mobility were compared between the two groups of patients. ResultsAll the 60 patients in this study completed the trial, and there was no recurrent case during treatment, after treatment or during follow-up. There was no statistically significant difference in age, gender, height, weight, body mass index, or course of disease between the two groups (P>0.05). Taking VAS score as the dependent variable, the result of generalized estimating equations showed that the difference in VAS score between the trial group and the control group was statistically significant (χ2=4.132, P=0.042), and the VAS scores at 12 weeks of follow-up and at 8 weeks of treatment differed significantly from that before treatment (χ2=1618.814, P<0.001; χ2=1573.419, P<0.001); the between-group comparisons at different time points showed that the difference in VAS score between the two groups at 12 weeks of follow-up was statistically significant (P<0.001), and the remaining between-group differences were not statistically significant (P>0.05). Taking ODI score as the dependent variable, the result of generalized estimating equations showed that the difference in total ODI score between the two groups was statistically significant (χ2=11.063, P=0.001), and the ODI scores at 12 weeks of follow-up and at 8 weeks of treatment differed significantly from that before treatment (χ2=524.694, P<0.001; χ2=717.236, P<0.001); the between-group comparisons at different time points showed that there were statistically significant differences between the two groups at 8 weeks of treatment and at 12 weeks of follow-up (P<0.001). After treatment, the improvement of stability value of abdominal pressure [(?4.93±8.14) vs. (?1.33±4.78) mm Hg (1 mm Hg=0.133 kPa)], the improvement of xiphoid level thoracic mobility [(1.87±0.62) vs. (1.52±0.70) cm] and the improvement of axillary level thoracic mobility [(1.78±0.62) vs. (0.92±0.45) cm] in the trial group were better than those in the control group (P<0.05).ConclusionThe dynamic neuromuscular stabilization technique can improve the dysfunction and relieve the symptoms of patients with chronic non-specific low back pain, and it is worthy of promotion.
Objective?To investigate the method of combining radial forearm free flap and adjacent tissue flap in reconstruction of palatomaxillary defects and its effectiveness.?Methods?Between March 2005 and May 2010, 17 patients with palatomaxillary defects were treated. There were 11 males and 6 females with an age range of 45-74 years (mean, 62.5 years), including 1 case of benign tumor and 16 cases of malignant tumors (7 cases of squamous cell carcinoma of palate, 1 case of recurring squamous cell carcinoma of palate, 1 case of malignant melanoma of palate, 1 case of adenoid cystic carcinoma of palate, 1 case of malignant melanoma of maxilla, 1 case of ductal carcinoma of maxilla, and 4 cases of squamous cell carcinoma of maxilla). The maxillectomy defect ranged from 7.0 cm × 5.5 cm to 10.0 cm × 7.5 cm. According to Brown’s classification for the maxillectomy defect, there were type II in 15 cases, type III in 2 cases. Palatomaxillary defects were repaired with radial forearm free flap and buccal fat pad in 11 cases, and with radial forearm free flap, buccal fat pad, and mandibular osteomuscular flap pedicled with temporal muscle in 6 cases. The effectiveness was evaluated after operation by observing the vitality of the flap, the functions of speech, swallowing, breath, and the facial appearance.?Results?All cases were followed up 6-12 months without tumor recurrence. All flaps and skin grafts at donor sites survived. The functions of seech, swallowing, and breath were normal without obvious opening limitation. The facial appearance was satisfactory without obvious maxillofacial deformity. No enophthalmos occurred in patients with orbital floor and infraorbital rim defects. The patients had no oronasal fistula with satisfactory oral and nasal functions.?Conclusion?According to the type of palatomaxillary defects, it can have good early effectiveness to select combining radial forearm free flap and buccal fat pad or combining radial forearm free flap, buccal fat pad, and mandibular osteomuscular flap for repairing defects.