1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "microwave ablation" 14 results
        • Short-term efficacy of CT-guided microwave ablation for solitary pulmonary nodules

          ObjectiveTo evaluate the clinical feasibility and safety of CT-guided percutaneous microwave ablation for peripheral solitary pulmonary nodules.MethodsThe imaging and clinical data of 33 patients with pulmonary nodule less than 3 cm in diameter treated by CT-guided microwave ablation treatment (PMAT) in our hospital from July 2018 to December 2019 were retrospectively analyzed. There were 21 males and 12 females aged 38-90 (67.6±13.4) years. Among them, 26 patients were confirmed with lung cancer by biopsy and 7 patients were clinically considered as partial malignant lesions. The average diameter of 33 nodules was 0.6-3.0 (1.8±0.6) cm. The 3- and 6-month follow-up CT was performed to evaluate the therapy method by comparing the diameter and enhancement degree of lesions with 1-month CT manifestation. Short-term treatment analysis including complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD) was calculated according to the WHO modified response evaluation criteria in solid tumor (mRECIST) for short-term efficacy evaluation. Eventually the result of response rate (RR) was calculated. Progression-free survival was obtained by Kaplan–Meier analysis.ResultsCT-guided percutaneous microwave ablation was successfully conducted in all patients. Three patients suffered slight pneumothorax. There were 18 (54.5%) patients who achieved CR, 9 (27.3%) patients PR, 4 (12.1%) patients SD and 2 (6.1%) patients PD. The short-term follow-up effective rate was 81.8%. Logistic analysis demonstrated that primary and metastatic pulmonary nodules had no difference in progression-free time (log-rank P=0.624).ConclusionPMAT is of high success rate for the treatment of solitary pulmonary nodules without severe complications, which can be used as an effective alternative treatment for nonsurgical candidates.

          Release date:2021-07-28 10:22 Export PDF Favorites Scan
        • Application of DynaCT combined with 3D iGuide puncture technique to microwave ablation of lung cancer

          ObjectiveTo investigate the feasibility and safety of DynaCT microwave ablation (MWA) guided by 3D iGuide puncture technology for lung cancer.MethodsThe clinical data of 19 patients with primary or metastatic lung cancer who underwent DynaCT MWA from June 2019 to December 2020 in our hospital were retrospectively analyzed, including 15 males and 4 females with an average age of 64.9±11.7 years. The technical success rates, adverse reactions and complications, postoperative hospital stay, and local therapeutic efficacy were recorded.ResultsTechnical success rate was 100.0%. The mean time required to target and place the needle was 15.7±3.7 min and the mean ablation time was 5.7±1.6 min. Thirteen patients underwent biopsy synchronously before the ablation, and 10 (76.9%) patients had positive pathological results. The main adverse reactions were pain (7/19, 36.8%), post-ablation syndrome (4/19, 21.1%) and cough (2/19, 10.5%). The minor complications were pneumothorax (6/19, 31.6%), hemorrhage (5/19, 26.3%), pleural effusion (2/19, 10.5%) and cavity (1/19, 5.3%). Three patients had moderate pneumothorax and received closed thoracic drainage. The median hospitalization time after ablation was 2.0 (2.0, 3.0) d, and no patient died during the perioperative period. The initial complete ablation rate was 89.5% (17 patients) and the incomplete ablation rate was 10.5% (2 patients) at 1-month follow-up, and no local progression was observed.ConclusionDynaCT MWA of lung cancer under the guidance of 3D iGuide system is safe and feasible with a high short-term local control rate, but the long-term efficacy remains to be further observed.

          Release date:2023-03-01 04:15 Export PDF Favorites Scan
        • Hemostatic efficacy of ultrasound-guided microwave ablation puncture technology for traumatic liver hemorrhage and its potential battlefield applicability

          Objective To examine the hemostatic efficacy of ultrasound-guided microwave ablation puncture technology for traumatic liver hemorrhage and assess its potential applicability within battlefield settings. Methods A randomized controlled animal trial was conducted utilizing 24 miniature pigs (weight 30-50 kg) meeting laboratory animal standards. A model of multiple liver injuries was created. Animals were randomly allocated into two groups: a microbubble contrast group (n=12, injected with SonoVue 0.1 mL/kg) and a normal saline control group (n=12). Under simulated battalion-level field rescue conditions, ultrasound-guided microwave ablation hemostasis for liver lacerations was performed using a KY2000 microwave therapy system (power 60 W). The ultrasound localization duration, puncture duration, hemostasis duration, and hemodynamic parameter alterations were recorded. Postoperative anatomical observation and pathological examination of the liver were conducted. Results There was no statistically significant difference in the ultrasound exploration time, hemostasis duration of para-diaphragmatic and para-gallbladder between the two groups (P>0.05). The hemostasis duration of para-hepatic artery in the microbubble contrast group was shorter than that in the control group (5.50±0.50 vs. 9.67±0.85; P<0.001). After hemostasis, the hemoglobin [(98.19±17.32) vs. (60.67±15.61) g/L; P<0.001], and packed cell volume [(0.34±0.03)% vs. (0.28±0.09)%; P<0.001] were higher than the control group; lymphocyte percentage [(61.09±5.16)% vs. (67.12±6.78)%; P<0.001] was lower than the control group. The pathological examination results showed that, a characteristic spindle-shaped zone of coagulative necrosis within the ablation area. Electron microscopy demonstrated ultrastructural alterations in hepatocytes, including mitochondrial cristae disruption. Conclusions Ultrasound-guided microwave ablation puncture technology enables rapid and effective control of liver hemorrhage, thereby demonstrating potential for battlefield utilization. Future efforts should prioritize the integrated development of ultrasound and microwave apparatuses, alongside stringent definition of battlefield indications.

          Release date:2025-11-26 05:22 Export PDF Favorites Scan
        • Research progress of microwave ablation combined with endoscopic technique for liver cancer

          Objective To summarize recent progress of microwave ablation combined with endoscopic technique for liver cancer. Method The literatures relevant to treatment of microwave ablation combined with endoscopic technique for liver cancer in recent years were identified by searching PubMed and CNKI, then summarized and reviewed. Results The treatment of endoscopic microwave ablation or it combined with hepatectomy, interventional embolization, neoadjuvant chemotherapy, and two-step hepatectomy could expand the treatment indications for liver cancer, increase the cure rate, and reduce the intraoperative bleeding, postoperative complications and recurrence. Conclusions Microwave ablation combined with endoscopic technique has less invasion and fast recovery for patient with liver cancer. Multi-disciplinary team collaboration and rational use of varied therapeutic methods in treatment of liver cancer could help to improve treatment effect and prolong survival time of patient.

          Release date:2017-05-04 02:26 Export PDF Favorites Scan
        • Clinical utility of electromagnetic navigation bronchoscopy-guided microwave ablation in patients with inoperable high-risk pulmonary nodules

          ObjectiveTo explore the clinical utility and safety of electromagnetic navigation bronchoscopy (ENB)-guided microwave ablation (MWA) in the patients with inoperable high-risk pulmonary nodules.MethodsClinical data of patients who were diagnosed with inoperable pulmonary nodules highly suspected as malignant tumors and treated with ENB-guided MWA in Zhongshan Hospital, Fudan University from December 2019 to September 2020 were retrospectively collected and analyzed to evaluate the efficacy and safety of the procedure. There were 6 males and 3 females aged 72.0 (59.5-77.0) years.ResultsTotally ENB-guided MWA was performed in 9 patients with 12 lesions. All patients suffered from at least one chronic comorbidity. The inoperable reasons included poor pulmonary function (55.6%), comorbidities of other organs which made the surgery intolerable (33.3%), multiple lesions in different lobes or segments (22.2%), personal wills (22.2%) and advanced in age (11.1%). The median diameter of nodules was 13.5 (9.5-22.0) mm and the median distance from the edge of nodules to pleura was 5.3 (1.8-16.3) mm. Bronchoscope maneuver to the targeted lesions was manipulated according to navigation pathway under visual and X-ray guidance and confirmed with radial ultrasound probe. Rapid on-site evaluation also helped with primary pathological confirmation of biopsy specimen. Among all the lesions, 4 adenocarcinoma, 1 non-small cell lung cancer-not otherwise specified and 2 inflammatory lesions were reported in postoperative pathological diagnosis, while no malignant cells were found in 5 specimens. The ablation success rate was 83.3% (10/12). For the two off-targeted lesions, percutaneous ablations were performed as salvage treatment subsequently. The median hospitalization time was 3.0 (2.0-3.0) days and no short-term complications were reported in these patients.ConclusionENB-guided MWA is a safe and effective procedure for patients with high-risk pulmonary nodules when thoracic surgery cannot be tolerated.

          Release date:2021-11-25 03:54 Export PDF Favorites Scan
        • Efficacy of ultrasound-guided percutaneous microwave ablation versus traditional open surgery for benign thyroid nodules: a systematic review

          ObjectivesTo systematically review the efficacy and safety of ultrasound-guided percutaneous microwave ablation versus traditional open surgical operation in the treatment of benign thyroid nodules.MethodsPubMed, The Cochrane Library, EMbase, CBM, CNKI and VIP databases were electronically searched to collect randomized controlled trials (RCTs) on ultrasound-guided percutaneous microwave ablation versus traditional open surgery for benign thyroid nodules from inception to June 30th, 2018. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Then, meta-analysis was then performed by RevMan 5.3 software.ResultsA total of 38 RCTs involving 4 078 patients were included. The results of meta-analysis showed that: ultrasound-guided percutaneous microwave ablation might be more effective than traditional open surgery for the treatment of benign thyroid nodules (RR=1.09, 95% CI 1.00 to 1.19, P=0.04), and compared with traditional open surgery, ultrasound-guided percutaneous microwave ablation reduced the rate of postoperative complication (RR=0.26, 95%CI 0.21 to 0.31, P<0.000 01), shortened postoperative hospital stay (MD=–3.60, 95%CI –4.04 to –3.15, P<0.000 01) and the time consumed in operation (MD=–48.79, 95%CI –54.16 to –43.41, P<0.000 01), and reduced operative blood loss (MD=–22.02, 95%CI–23.87 to –20.17, P<0.000 01). Meanwhile, microwave ablation reduced the elevated levels of serum IL-6 content (MD=–10.34, 95%CI –10.70 to –9.97, P<0.000 01), serum CRP content (MD=–9.70, 95%CI –10.95 to –8.44, P<0.000 01) and serum TNF-α content (MD=–7.94, 95%CI –9.00 to –6.88, P<0.000 01).ConclusionsCurrent evidence shows that ultrasound-guided percutaneous microwave ablation may improve clinical efficacy and can reduce postoperative complications, bleeding volume, operation time, hospitalization days and postoperative inflammatory reaction. Due to limited quality and quantity of the included studies, more high quality studies are required to verify above conclusions.

          Release date:2019-03-21 10:45 Export PDF Favorites Scan
        • An in vivo study of ultrasonic monitoring imaging of microwave ablation based on Nakagami statistic parameter

          This paper explored the feasibility of using ultrasonic Nakagami statistic parameter imaging to evaluate the thermal lesion induced by microwave ablation (MWA) in porcine models. In this paper, thermal lesions were induced in livers and kidneys in 5 swines using a clinical MWA system. During this treatment progress, ultrasonic radiofrequency (RF) data were collected. The dynamic changes of Nakagami parameter in the thermal lesion were calculated, and the ultrasonic B-mode images and Nakagami images were reconstructed simultaneously. The contrast-to-noise ratio (CNR) between the thermal lesion and the surrounding normal tissue was calculated over the MWA procedure. After MWA, a bright hyperechoic region appeared in the ultrasonic Nakagami image as an indicator of the thermal lesion and this bright spot enlarged with lesion development during MWA exposure. The mean value of Nakagami parameter in the liver and kidney increased from 0.78 and 0.79 before treatment to 0.91 and 0.92 after treatment, respectively. During MWA exposure, the mean values of CNR calculated from the Nakagami parameter increased from 0.49 to 1.13 in the porcine liver and increased from 0.51 to 0.85 in the kidney, which were both higher than those calculated from the B-mode images. This in vivo study on porcine models suggested that the ultrasonic Nakagami imaging may provide an alternative modality for monitoring MWA treatment.

          Release date:2019-06-17 04:41 Export PDF Favorites Scan
        • Monitoring microwave ablation using ultrasound backscatter homodyned K imaging: Comparison of estimators

          The feasibility of ultrasound backscatter homodyned K model parametric imaging (termed homodyned K imaging) to monitor coagulation zone during microwave ablation was investigated. Two recent estimators for the homodyned K model parameter, RSK (the estimation method based on the signal-to-noise ratio, the skewness, and the kurtosis of the amplitude envelope of ultrasound) and XU (the estimation method based on the first moment of the intensity of ultrasound, X statistics and U statistics), were compared. Firstly, the ultrasound backscattered signals during the microwave ablation of porcine liver ex vivo were processed by the noise-assisted correlation algorithm, envelope detection, sliding window method, digital scan conversion and color mapping to obtain homodyned K imaging. Then 20 porcine livers’ microwave ablation experiments ex vivo were used to evaluate the effect of homodyned K imaging in monitoring the coagulation zone. The results showed that the area under the receiver operating characteristic curve of the RSK method was 0.77 ± 0.06 (mean ± standard deviation), and that of the XU method was 0.83 ± 0.08 (mean ± standard deviation). The accuracy to monitor the coagulation zone was (86 ± 10)% (mean ± standard deviation) by the RSK method and (90 ± 8)% (mean ± standard deviation) by the XU method. Compared with the RSK method, the Bland-Altman consistency for the coagulation zone estimated by the XU method and that of actual porcine liver tissue was higher. The time for parameter estimation and imaging by the XU method was less than that by the RSK method. We conclude that ultrasound backscatter homodyned K imaging can be used to monitor coagulation zones during microwave ablation, and the XU method is better than the RSK method.

          Release date:2021-08-16 04:59 Export PDF Favorites Scan
        • Progress in ablation therapy of pulmonary nodules

          In recent years, with the improvement of people's awareness of physical examination and the more accurate detection equipment, the detection rate of pulmonary nodules is getting higher and higher. Surgical resection is the first choice for the treatment of malignant pulmonary nodules, but multiple pulmonary nodules, nodules in complex areas and those with surgical contraindications are not suitable for surgery. As an effective, less invasive and low-cost treatment, ablation has developed rapidly in the treatment of multiple pulmonary nodules. This article introduces the progress of several common ablation techniques (radiofrequency ablation, microwave ablation, cryoablation) in the treatment of multiple pulmonary nodules, the indications and contraindications of ablation techniques, the efficacy evaluation and complications after ablation therapy, and the prospects of ablation techniques in the treatment of multiple pulmonary nodules.

          Release date:2025-02-28 06:45 Export PDF Favorites Scan
        • Research advances in thermal ablation for lung cancer

          Although surgical resection remains to be the best treatment strategy for stageⅠnon-small cell lung cancer (NSCLC), percutaneous thermal ablation offers an important option for patients who are unable to undergo surgical resection. Currently, there are three main thermal ablation methods used in the treatment of lung cancer, including radiofrequency ablation (RFA), microwave ablation (MWA) and argon-helium cryoablation (AHC). With the improvement of technique and the accumulation of experience in the treatment of lung cancer, some limitations are disclosed in the initial application of RFA, such as heat sink effect, skin burns and rapid carbonization. These shortcomings have been overcome in the development of MWA and AHC. The feasibility and safety of thermal ablation for the treatment of lung cancer has been demonstrated and its efficacy has been significantly improved (especially for the tumour diameter≤3 cm). This article will focus on the application and recent research developments of these ablation techniques in the treatment of lung cancer.

          Release date: Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品