Computational fluid dynamics was used to investigate the effect of the pathogenesis of membranous obstruction of inferior vena cava of Budd-Chiari syndrome with various angles between right hepatic vein and inferior vena cava. Mimics software was used to reconstruct the models from magnetic resonance imaging (MRI) angiograms of inferior vena cava, right hepatic vein, middle hepatic vein and left hepatic vein, and 3DMAX was used to construct the models of 30°, 60°, 90° and 120° angles between right hepatic vein and inferior vena cava, which was based on the reconstructed models.The model was conducted with clinical parameters in terms of wall shear stress distribution, static pressure distribution and blood velocity. The results demonstrated that the differences between wall shear stress and static pressure had statistical significance with various angles between right hepatic vein and inferior vena cava by SPSS. The pathogenesis of membranous obstruction of inferior vena cava had a correlation with the angles between right hepatic vein and inferior vena cava.
To solve the problem of stent malapposition of intravascular stents, explore the design method of intravascular body-fitted stent structure and to establish an objective apposition evaluation method, the support and apposition performance of body-fitted stent in the stenotic vessels with different degrees of calcified plaque were simulated and analyzed. The traditional tube-mesh-like stent model was constructed by using computational aided design tool SolidWorks, and based on this model, the body-fitted stent model was designed by means of projection algorithm. Abaqus was used to simulate the crimping-expansion-recoil process of the two stents in the stenotic vessel with incompletely calcified plaque and completely calcified plaque respectively. A comprehensive method for apposition evaluation was proposed considering three aspects such as separation distance, fraction of non-contact area and residual volume. Compared with the traditional stent, the separation distances of the body-fitted stent in the incompletely calcified plaque model and the completely calcified plaque model were decreased by 21.5% and 22.0% respectively, the fractions of non-contact areas were decreased by 11.3% and 11.1% respectively, and the residual volumes were decreased by 93.1% and 92.5% respectively. The body-fitted stent improved the apposition performance and was effective in both incompletely and completely calcified plaque models. The established apposition performance evaluation method of stent considered more geometric factors, and the results were more comprehensive and objective.
Objective To investigate the effects of different types of tricuspid regurgitation, implantation positions, and device models on the treatment outcomes of K-Clip for tricuspid regurgitation using numerical simulations. Methods Three-dimensional reconstruction of the heart model was performed based on CT images. Two different regurgitation orifices were obtained by modifying the standard parameterized tricuspid valve leaflets and chordae tendineae. The effects of different K-Clip models at different implantation positions (posterior leaflet midpoint, anterior-posterior commissure, anterior leaflet midpoint, posterior septal commissure) were simulated using commercial explicit dynamics software Ls-Dyna. Conclusion For the two types of regurgitation in this study, clipping at the posterior leaflet midpoint resulted in a better reduction of the regurgitation orifice (up to 75% reduction in area). Higher clamping forces were required for implantation at the anterior leaflet midpoint and posterior septal commissure, which was unfavorable for the smooth closure of the clipping components. There was no statistical difference in the treatment outcomes between the 18T and 16T K-Clip components, and the 16T component required less clamping force. Therefore, the use of the 16T K-Clip component is recommended.
A solid-liquid two-phase finite element model of articular cartilage and a microscopic finite element model of chondrocytes were established using the finite element software COMSOL in this study. The purpose of the study is to investigate the mechanics environment and the liquid flow field of the host cartilage chondrocytes in each layer by multi-scale method, under physiological load, with the different elastic modulus of artificial cartilage to repair cartilage defect. The simulation results showed that the uniform elastic modulus of artificial cartilage had different influences on the microenvironment of different layer chondrocytes. With the increase of the elastic modulus of artificial cartilage, the stress of the shallow surface layer and the intermediate layer chondrocytes increased and the stress of deep layer chondrocytes decreased. The flow field direction of the middle layer and the bottom layer of cartilage can also be changed by artificial cartilage implantation, as well as the ways of nourishment supply of the middle layer and underlying chondrocytes change. A barrier to underlying chondrocytes nutrition supply may be caused by this, thus resulting in the uncertainty of the repair results. With cross-scale finite element model simulation analysis of chondrocytes, we can quantitatively evaluate the mechanical environment of chondrocytes in each layer of the host cartilage. It is helpful to assess the clinical effect of cartilage defect reparation more accurately.
A three-dimensional (3D) model of human anterior chamber is reconstructed to explore the effect of different corneal temperatures on the heat transfer in the chamber. Based on the optical coherence tomography imaging of the volunteers with normal anterior chamber, a 3D anterior chamber model was reconstructed by the method of UG parametric design. Numerical simulation of heat transfer and aqueous humor flow in the whole anterior chamber were analyzed by the finite volume methods at different corneal temperatures. The results showed that different corneal temperatures had obvious influence on the temperature distribution and the aqueous flow in the anterior chamber. The temperature distribution is linear and axial symmetrical around the pupillary axis. As the temperature difference increases, the symmetry becomes poorer. Aqueous floated along the warm side and sank along the cool side which forms a vortexing flow. Its velocity increased with the addition of temperature difference. Heat fluxes of cornea, lens andiris were mainly affected by the aqueous velocity. The higher the velocity, the bigger more absolute value of the above-mentioned heat fluxes became. It is practicable to perform the numerical simulation of anterior chamber by the optical coherence tomography imaging. The results are useful for studying the important effect of corneal temperature on the heat transfer and aqueous humor dynamics in the anterior chamber.
Atherosclerosis is a complex and multi-factorial pathophysiological process. Researches over the past decades have shown that the development of atherosclerotic vulnerable plaque is closely related to its components, morphology, and stress status. Biomechanical models have been developed by combining with medical imaging, biological experiments, and mechanical analysis, to study and analyze the biomechanical factors related to plaque vulnerability. Numerical simulation could quantify the dynamic changes of the microenvironment within the plaque, providing a method to represent the distribution of cellular and acellular components within the plaque microenvironment and to explore the interaction of lipid deposition, inflammation, angiogenesis, and other processes. Studying the pathological mechanism of plaque development would improve our understanding of cardiovascular disease and assist non-invasive inspection and early diagnosis of vulnerable plaques. The biomechanical models and numerical methods may serve as a theoretical support for designing and optimizing treatment strategies for vulnerable atherosclerosis.
Atherosclerotic plaque rupture is the main cause of many cardiovascular diseases, and biomechanical factors play an important role in the process of plaque rupture. In the study of plaque biomechanics, there are relatively few studies based on fatigue fracture failure theory, and most of them mainly focus on the whole fatigue propagation process from crack initiation to plaque rupture, while there are few studies on the influence of crack on plaque rupture at a certain time in the process of fatigue propagation. In this paper, a two-dimensional plaque model with crack was established. Based on the theory of fracture mechanics and combined with the finite element numerical simulation method, the stress intensity factor (SIF) and related influencing factors at the crack tip in the plaque were studied. The SIF was used to measure the influence of crack on plaque rupture. The results show that the existence of crack can lead to local stress concentration, which increases the risk of plaque rupture. The SIF at the crack tip in the plaque was positively correlated with blood pressure, but negatively correlated with fibrous cap thickness and lipid pool stiffness. The effect of the thickness and angle of lipid pool on the SIF at the crack tip in the plaque was less than 4%, which could be ignored. This study provides a theoretical basis for the risk assessment of plaque rupture with cracks.
Due to their diverse types, complex causes, high incidence, and difficult treatment, lung diseases have become major killers threatening human life and health, and some lung diseases have a significant impact on alveolar morphology and histology. Numerical simulation of alveolar mechanical response, alveolar flow field information, multiphase flow, and material transport based on computational fluid dynamics is of great significance for lung disease diagnosis, clinical treatment, and in vitro experiments. Starting from the simplification and pathological differences of geometric and mechanical models, this paper analyzes and summarizes the conditions and application scenarios of the airflow dynamics calculation method in pulmonary alveoli, to provide a reference for further simulation and application of the alveolar region.
Inhalable particles deposition in the human respiratory system is the main cause of many respiratory and cardiovascular diseases. It plays an important role in related disease prevention and treatment through establishing computer or external entity models to study rules of particle deposition. The paper summarized and analyzed the present research results of various inhalable particle deposition models of upper respiratory tract and pulmonary area, and expounded the application in the areas of disease inducement analysis, drug inhale treatment etc. Based on the review, the paper puts forward the problems and application limitations of present research, especially pointing out future emphasis in development directions. It will have a value of reference guidance for further systematic and in-depth study on the inhalable particle deposition simulation, experiment and application.
The current finite element analysis of vascular stent expansion does not take into account the effect of the stent release pose on the expansion results. In this study, stent and vessel model were established by Pro/E. Five kinds of finite element assembly models were constructed by ABAQUS, including 0 degree without eccentricity model, 3 degree without eccentricity model, 5 degree without eccentricity model, 0 degree axial eccentricity model and 0 degree radial eccentricity model. These models were divided into two groups of experiments for numerical simulation with respect to angle and eccentricity. The mechanical parameters such as foreshortening rate, radial recoil rate and dog boning rate were calculated. The influence of angle and eccentricity on the numerical simulation was obtained by comparative analysis. Calculation results showed that the residual stenosis rates were 38.3%, 38.4%, 38.4%, 35.7% and 38.2% respectively for the 5 models. The results indicate that the pose has less effect on the numerical simulation results so that it can be neglected when the accuracy of the result is not highly required, and the basic model as 0 degree without eccentricity model is feasible for numerical simulation.