1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "three-dimensional reconstruction" 38 results
        • ANATOMIC STUDY ON HOOK OF HAMATE BONE

          Objective To study the hook of hamate bone by anatomy and iconography methods in order to provide information for the cl inical treatment of injuries to the hook of hamate bone and the deep branch of ulnar nerve. Methods Fifty-two upper l imb specimens of adult corpses contributed voluntarily were collected, including 40 antisepticized old specimens and 12 fresh ones. The hook of hamate bone and its adjacent structure were observed. Twentyfour upper l imbs selected randomly from specimens of corpses and 24 upper l imbs from 12 healthy adults were investigated by computed tomography (CT) three-dimensional reconstruction, and then related data were measured. The measurement results of24 specimens were analyzed statistically. Results The hook of hamate bone is an important component of ulnar carpal canal and carpal canal, and the deep branch of ulnar nerve is located closely in the inner front of the hook of hamate bone. The flexor tendons of the forth and the l ittle fingers are in the innermost side, closely l ie next to the outside of the hook of hamate bone. The hamate bone located between the capitate bone and the three-cornered bone with wedge-shaped. The medial-, lateral-, and front-sides are all facies articularis. The hook of hamate bone has an approximate shape of a flat plate. The position migrated from the body of the hamate bone, the middle of the hook and the enlargement of the top of the hook were given the names of “the basis of the hook”, “the waist of the hook”, and “the coronal of the hook”, respectively. The short path of the basement are all longer than the short path of the waist. The long path of the top of the hook is the maximum length diameter of the hook of hamate bone, and is longer than the long path of the basement and the long path of the waist. The iconography shape and trait of the hook of hamate bone is similar to the anatomy result. There were no statistically significant differences (P gt; 0.05) between two methods in the seven parameters as follows: the long path of the basement of the hook, the short path of the basement of the hook, the long path of the waist of thehook, the short path of the waist of the hook, the long path of the top of the hook, the height of the hook, of hamate bone, and the distance between the top and the waist of the hook. Conclusion The hook of hamate bone can be divided into three parts: the coronal part, the waist part, and the basal part; fracture of the hamate bone can be divided into fracture of the body, fracture of the hook, and fracture of the body and the hook. Facture of the hook of hamate bone or fracture unnion can easily result in injure of the deep branch of ulnar nerve and the flexor tendons of the forth and the l ittle fingers. The measurement results of CT threedimensional reconstruction can be used as reference value directly in cl inical treatments.

          Release date:2016-08-31 05:47 Export PDF Favorites Scan
        • APPLICATION OF THREE-DIMENSIONAL CEPHALOMETRIC ANALYSIS IN ORTHOGNATHIC SURGERY

          ObjectiveTo establish a model of three-dimensional (3-D) cephalometric analysis to study dentomaxillofacial deformities. MethodsBetween January 2012 and October 2013,15 patients with dentomaxillofacial deformities were treated using 3-D cephalometric analysis in orthognathic surgery plan.There were 7 males and 8 females with an average age of 23.6 years (range,17-37 years),including 4 cases of mandibular protrusion with maxillary deficiency,4 cases of maxillary protrusion with mandibular deficiency,2 cases of long face syndrome,and 5 cases of facial asymmetry.CT images were reconstructed by Mimics software.The anatomical landmarks were located,the reference planes and analysis planes were defined and the 3-D coordinate was established.The distance and degree between landmarks and analysis planes which defined in the measure project were measured. ResultsBased on the 3-D CT quantitative analysis methods,cephalometric analysis project was defined in the 3-D coordinate.3-D cephalometric analysis provided a convenient and precise method for the clinical measurement of dentomaxillofacial morphology,and reduce the time in preoperation analysis. ConclusionThe model of 3-D CT cephalometric analysis can provide precise information in the diagnosis and treatment planning of orthognathic surgery.

          Release date: Export PDF Favorites Scan
        • Application of three-dimentional visualized reconstruction technology in resection of treating hepatic alveolar echinococcosis

          Objective To evaluate effects of three-dimensional (3D) visualized reconstruction technology on short-term benefits of different extent of resection in treating hepatic alveolar echinococcosis (HAE) as well as some disadvantages. Methods One hundred and fifty-two patients with HAE from January 2014 to December 2016 in the Department Liver Surgery, West China Hospital of Sichuan University were collected, there were 80 patients with ≥4 segments and 72 patients with ≤3 segments of liver resection among these patients, which were designed to 3D reconstruction group and non-3D reconstruction group according to the preference of patients. The imaging data, intraoperative and postoperative indicators were recorded and compared. Results The 3D visualized reconstructions were performed in the 79 patients with HAE, the average time of 3D visualized reconstruction was 19 min, of which 13 cases took more than 30 min and the longest reached 150 min. The preoperative predicted liver resection volume of the 79 patients underwent the 3D visualized reconstruction was (583.6±374.7) mL, the volume of intraoperative actual liver resection was (573.8±406.3) mL, the comparison of preoperative and intraoperative data indicated that both agreed reasonably well (P=0.640). Forty-one cases and 38 cases in the 80 patients with ≥4 segments and 72 patients with ≤3 segments of liverresection respectively were selected for the 3D visualized reconstruction. For the patients with ≥4 segments of liver resection, the operative time was shorter (P=0.021) and the blood loss was less (P=0.047) in the 3D reconstruction group as compared with the non-3D reconstruction group, the status of intraoperative blood transfusion had no significant difference between the 3D reconstruction group and the non-3D reconstruction group (P=0.766). For the patients with ≤3 segments of liver resection, the operative time, the blood loss, and the status of intraoperative blood transfusion had no significant differences between the 3D reconstruction group and the non-3D reconstruction group (P>0.05). For the patients with ≥4 segments or ≤3 segments of liver resection, the laboratory examination results within postoperative 3 d, complications within postoperative 90 d, and the postoperative hospitalization time had no significant differences between the 3D reconstruction group and the non-3D reconstruction group (P>0.05). Conclusion 3D visualized reconstruction technology contributes to patients with HAE ≥4 segments of liver resection, it could reduce intraoperative blood loss and shorten operation time, but it displays no remarkable benefits for ≤3 segments of liver resection.

          Release date:2018-05-14 04:18 Export PDF Favorites Scan
        • Numerical Simulation of Heat Transfer in the Human Anterior Chamber at Different Corneal Temperatures

          A three-dimensional (3D) model of human anterior chamber is reconstructed to explore the effect of different corneal temperatures on the heat transfer in the chamber. Based on the optical coherence tomography imaging of the volunteers with normal anterior chamber, a 3D anterior chamber model was reconstructed by the method of UG parametric design. Numerical simulation of heat transfer and aqueous humor flow in the whole anterior chamber were analyzed by the finite volume methods at different corneal temperatures. The results showed that different corneal temperatures had obvious influence on the temperature distribution and the aqueous flow in the anterior chamber. The temperature distribution is linear and axial symmetrical around the pupillary axis. As the temperature difference increases, the symmetry becomes poorer. Aqueous floated along the warm side and sank along the cool side which forms a vortexing flow. Its velocity increased with the addition of temperature difference. Heat fluxes of cornea, lens andiris were mainly affected by the aqueous velocity. The higher the velocity, the bigger more absolute value of the above-mentioned heat fluxes became. It is practicable to perform the numerical simulation of anterior chamber by the optical coherence tomography imaging. The results are useful for studying the important effect of corneal temperature on the heat transfer and aqueous humor dynamics in the anterior chamber.

          Release date: Export PDF Favorites Scan
        • Experimental study on repairing rabbit skull defect with bone morphogenetic protein 2 peptide/functionalized carbon nanotube composite

          ObjectiveTo observe and compare the effects of peptides on the repair of rabbit skull defects through two different binding modes of non-covalent and covalent, and the combination of carboxyl (-COOH) and amino (-NH2) groups with materials.MethodsTwenty-one 3-month-old male ordinary New Zealand white rabbits were numbered 1 to 42 on the left and right parietal bones. They were divided into 5 groups using a random number table, the control group (group A, 6 sides) and the material group 1, 2, 3, 4 (respectively group B, C, D, E, 9 sides in each group). All animals were prepared with 12-mm-diameter skull defect models, and bone morphogenetic protein 2 (BMP-2) non-covalently bound multiwalled carbon nanotubes (MWCNT)-COOH+poly (L-lactide) (PLLA), BMP-2 non-covalently bound MWCNT-NH2+PLLA, BMP-2 covalently bound MWCNT-COOH+PLLA, and BMP-2 covalently bound MWCNT-NH2+PLLA were implanted into the defects of groups B, C, D, and E, respectively. At 4, 8, and 12 weeks after operation, the samples were taken for CT scanning and three-dimensional reconstruction, the ratio of bone tissue regeneration volume to total volume and bone mineral density were measured, and the histological observation of HE staining and Masson trichrome staining were performed to quantitatively analyze the volume ratio of new bone tissue.ResultsCT scanning and three-dimensional reconstruction showed that with the extension of time, the defects in groups A-E were filled gradually, and the defect in group E was completely filled at 12 weeks after operation. HE staining and Masson trichrome staining showed that the volume of new bone tissue in each group gradually increased with time, and regenerated mature bone tissue appeared in groups D and E at 12 weeks after operation. Quantitative analysis showed that at 4, 8, and 12 weeks after operation, the ratio of bone tissue regeneration volume to total volume, bone mineral density, and the volume ratio of new bone tissue increased gradually over time; and at each time point, the above indexes increased gradually from group A to group E, and the differences between groups were significant (P<0.05).ConclusionThrough covalent binding and using -NH2 to bound peptides with materials, the best bone repair effect can be achieved.

          Release date:2021-03-26 07:36 Export PDF Favorites Scan
        • Research on Three-dimensional Medical Image Reconstruction and Interaction Based on HTML5 and Visualization Toolkit

          Integrating visualization toolkit and the capability of interaction, bidirectional communication and graphics rendering which provided by HTML5, we explored and experimented on the feasibility of remote medical image reconstruction and interaction in pure Web. We prompted server-centric method which did not need to download the big medical data to local connections and avoided considering network transmission pressure and the three-dimensional (3D) rendering capability of client hardware. The method integrated remote medical image reconstruction and interaction into Web seamlessly, which was applicable to lower-end computers and mobile devices. Finally, we tested this method in the Internet and achieved real-time effects. This Web-based 3D reconstruction and interaction method, which crosses over internet terminals and performance limited devices, may be useful for remote medical assistant.

          Release date: Export PDF Favorites Scan
        • Three-dimensional morphological study of the effect of false acetabulum on the femoral structure in Crowe type Ⅳ developmental dysplasia of the hip

          ObjectiveTo explore the effect of false acetabulum on the development and anatomical morphology of proximal femur in Crowe type Ⅳ developmental dysplasia of the hip (DDH), providing a theoretical basis for the development of femoral reconstruction strategy and prosthesis selection for total hip arthroplasty. Methods The medical records of 47 patients (54 hips) with Crowe type Ⅳ DDH between February 2008 and March 2020 were retrospectively analyzed, of which 21 patients (26 hips) were Crowe type Ⅳa (type Ⅳa group) and 26 patients (28 hips) were Crowe type Ⅳb (type Ⅳb group). There was no significant difference in general data such as gender, age, height, weight, body mass index, and side between the two groups (P>0.05), which were comparable. The height of femoral head dislocation, the height of pelvis, and the proportion of dislocation were measured based on preoperative anteroposterior pelvic X-ray film. Based on the preoperative femoral CT scan data, the anatomical parameters of the femur and femoral medullary cavity were measured after three-dimensional reconstruction using Mimics19.0 software to calculate the canal fare index; and the femoral medullary cavity parameters were matched with the modular S-ROM prosthesis parameters. ResultsThe results of X-ray film measurement showed that the height of femoral head dislocation and the proportion of dislocation in type Ⅳa group were significantly higher than those in type Ⅳb group (P<0.05). There was no significant difference in the height of pelvis between the two groups (P>0.05). The results of CT three-dimensional reconstruction measurements showed that compared with the type Ⅳb group, the type Ⅳa group had less isthmus height, smaller femoral head, shorter femoral neck, narrower neck-shaft angle, increased anteversion angle, and higher greater trochanter, and the differences were significant (P<0.05). There was no significant difference in the height of femoral head, femoral offset, and height difference between greater trochanter and femoral head between the two groups (P>0.05). There was no significant difference in the mediolateral width (ML), anteroposterior width (AP), and diameter of the isthmus (Ci level) and the AP of the medullary cavity in the plane 40 mm distal to the most prominent point on the medial side of the lesser trochanter (C–40 level) (P>0.05), and the size of medullary cavity was significantly smaller in type Ⅳa group than in type Ⅳb group at the other levels (P<0.05). Compared with the type Ⅳb group, the difference between the outer diameter of the prosthetic sleeve and the diameter of the medullary cavity fitting circle in the plane where the center of femoral head rotation was located from the medial most prominent point of the lesser trochanter (C0 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). The difference between the longest diameter of the prosthetic sleeve triangle and the ML of the medullary cavity in the plane 10 mm proximal to the most prominent point on the medial side of the lesser trochanter (C+10 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). ConclusionFalse acetabulum has a significant impact on the morphology of the proximal femur and medullary cavity in patients with Crowe type Ⅳ DDH, and the application of three-dimensional reconstruction technique can accurately evaluate the femoral morphology and guide the selection of femoral prosthesis.

          Release date:2022-06-29 09:19 Export PDF Favorites Scan
        • A study of the correlation between glenohumeral joint congruence and stability in recurrent shoulder dislocations

          ObjectiveTo investigate the correlation between glenohumeral joint congruence and stability in recurrent shoulder dislocations. Methods Eighty-nine patients (89 sides) with recurrent shoulder dislocation admitted between June 2022 and June 2023 and met the selection criteria were included as study subjects. There were 36 males and 53 females with an average age of 44 years (range, 20-79 years). There were 40 cases of left shoulder and 49 cases of right shoulder. The shoulder joints dislocated 2-6 times, with an average of 3 times. The three-dimensional models of the humeral head and scapular glenoid were reconstructed using Mimics 20.0 software based on CT scanning images. The glenoid track (GT), inclusion index, chimerism index, fit index, and Hill-Sachs interval (HSI) were measured, and the degree of on/off track was judged (K value, the difference between HSI and GT). Multiple linear regression was used to analyze the correlation between the degree of on/off track (K value) and inclusion index, chimerism index, and fit index. ResultsMultiple linear regression analysis showed that the K value had no correlation with the inclusion index (P>0.05), and was positively correlated with the chimerism index and the fit index (P<0.05). Regression equation was K=–24.898+35.982×inclusion index+8.280×fit index, R2=0.084. ConclusionHumeral head and scapular glenoid bony area and curvature are associated with shoulder joint stability in recurrent shoulder dislocations. Increased humeral head bony area, decreased scapular glenoid bony area, increased humeral head curvature, and decreased scapular glenoid curvature are risk factors for glenohumeral joint stability.

          Release date:2023-09-07 04:22 Export PDF Favorites Scan
        • Puncture positioning versus free-of-puncture positioning under three-dimensional navigation in the anatomical segmentectomy for pulmonary nodules: A retrospective cohort study

          ObjectiveTo explore the feasibility and clinical value of free-of-puncture positioning in three-dimension-guided anatomical segmentectomy for ground-glass nodule (GGN) compared with percutaneous positioning.MethodsClinical data of 268 enrolled patients undergoing anatomical pulmonary segmentectomy from October 2018 to June 2019 were retrospectively collected, including 75 males and 193 females with an average age of 56.55±12.10 years. The patients were divided into two groups, including a percutaneous positioning group (n=89) and a free-of-puncture positioning group (n=179). Perioperative data of the two groups were compared.ResultsThe average CT scan times of the percutaneous positioning group was 3.01±0.98 times, and the numerical rating scale (NRS) score of puncture pain was 3.98±1.61 points. Pulmonary compression pneumothorax (≥30%) occurred in 7 (7.87%) patients and intercostal vascular hemorrhage occurred in 8 (8.99%) patients after puncture. Lung nodules were successfully found and removed in both groups. There was no statistically significant difference between the two groups in the location of nodules (P=0.466), operation time (151.83±39.23 min vs. 154.35±33.19 min, P=0.585), margin width (2.07±0.35 cm vs. 1.98±0.28 cm, P=0.750), or the number of excised subsegments (2.83±1.13 vs. 2.73±1.16, P=0.530).ConclusionAnatomical segmentectomy with three-dimensional navigation avoids the adverse consequences of puncture, which has the same clinical efficacy and meets the requirements of oncology compared with percutaneous positioning. The free-of-puncture positioning method can be used for GGN located in the central region of pulmonary segment/subsegment or adjacent to intersegment veins instead of percutaneous positioning.

          Release date:2021-10-28 04:13 Export PDF Favorites Scan
        • 18F-FDG PET/CT combined with CT three-dimensional reconstruction in the differentiation of benign and malignant pulmonary nodules: A retrospective cohort study

          Objective To investigate the accuracy of 18F-FDG positron emission tomography/computed tomography (PET/CT) combined with CT three-dimensional reconstruction (CT-3D) in the differential diagnosis of benign and malignant pulmonary nodules. Methods The clinical data of patients who underwent pulmonary nodule surgery in the Department of Thoracic Surgery, Northern Jiangsu People's Hospital from July 2020 to August 2021 were retrospectively analyzed. The preoperative 18F-FDG PET/CT and chest enhanced CT-3D and other imaging data were extracted. The parameters with diagnostic significance were screened by the area under the receiver operating characteristic (ROC) curve (AUC). Three prediction models, including PET/CT prediction model (MOD PET), CT-3D prediction model (MOD CT-3D), and PET/CT combined CT-3D prediction model (MOD combination), were established through binary logistic regression, and the diagnostic performance of the models were validated by ROC curve. Results A total of 125 patients were enrolled, including 57 males and 68 females, with an average age of 61.16±8.57 years. There were 46 patients with benign nodules, and 79 patients with malignant nodules. A total of 2 PET/CT parameters and 5 CT-3D parameters were extracted. Two PET/CT parameters, SUVmax≥1.5 (AUC=0.688) and abnormal uptake of hilar/mediastinal lymph node metabolism (AUC=0.671), were included in the regression model. Among the CT-3D parameters, CT value histogram peaks (AUC=0.694) and CT-3D morphology (AUC=0.652) were included in the regression model. Finally, the AUC of the MOD PET was verified to be 0.738 [95%CI (0.651, 0.824)], the sensitivity was 74.7%, and the specificity was 60.9%; the AUC of the MOD CT-3D was 0.762 [95%CI (0.677, 0.848)], the sensitivity was 51.9%, and the specificity was 87.0%; the AUC of the MOD combination was 0.857 [95%CI (0.789, 0.925)], the sensitivity was 77.2%, the specificity was 82.6%, and the differences were statistically significant (P<0.001). Conclusion 18F-FDG PET/CT combined with CT-3D can improve the diagnostic performance of pulmonary nodules, and its specificity and sensitivity are better than those of single imaging diagnosis method. The combined prediction model is of great significance for the selection of surgical timing and surgical methods for pulmonary nodules, and provides a theoretical basis for the application of artificial intelligence in the pulmonary nodule diagnosis.

          Release date:2024-02-20 04:11 Export PDF Favorites Scan
        4 pages Previous 1 2 3 4 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品