1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

        <em id="8sgz1"><label id="8sgz1"></label></em>
      2. <em id="8sgz1"><label id="8sgz1"></label></em>
        <em id="8sgz1"></em>
        <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

        <button id="8sgz1"></button>
        west china medical publishers
        Keyword
        • Title
        • Author
        • Keyword
        • Abstract
        Advance search
        Advance search

        Search

        find Keyword "tibial plateau" 17 results
        • Biomechanical study on nickel-titanium three-dimensional memory alloy mesh combined with autologous bone for living model of canine tibial plateau collapse fracture

          ObjectiveTo evaluate the effect of nickel-titanium three-dimensional memory alloy mesh combined with autologous bone for living model of canine tibial plateau collapse fracture by biomechanical testing. MethodsSixteen healthy 12-month-old Beagle dogs were randomly divided into 4 group, 4 dogs in each group. The dogs were used to establish the tibial plateau collapse fracture model in groups A, B, and C. Then, the nickel-titanium three-dimensional memory alloy mesh combined with autologous bone (the fibula cortical bone particles), the artificial bone (nano-hydroxyapatite), and autologous fibula cortical bone particles were implanted to repair the bone defects within 4 hours after modeling in groups A, B, and C, respectively; and the plate and screws were fixed outside the bone defects. The dogs were not treated in group D, as normal control. At 5 months after operation, all animals were sacrificed and the tibial specimens were harvested and observed visually. The destructive axial compression experiments were carried out by the biomechanical testing machine. The displacement and the maximum failure load were recorded and the axial stiffness was calculated. ResultsAll animals stayed alive after operation, and all incisions healed. After 1-3 days of operation, the animals could stand and move, and no obvious limb deformity was found. The articular surfaces of the tibial plateau specimens were completely smooth at 5 months after operation. No obvious articular surface collapse was observed. The displacement and maximum failure load of specimens in groups A and D were significantly higher than those in groups B and C (P<0.05). But no significant difference was found between groups A and D and between groups B and C (P>0.05). ConclusionThe nickel-titanium three-dimensional memory alloy mesh combined with autologous bone for subarticular bone defect of tibial plateau in dogs has good biomechanical properties at 5 months after operation, and has better axial stiffness when compared with the artificial bone and autologous bone graft.

          Release date:2018-12-04 03:41 Export PDF Favorites Scan
        • Application of modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column

          ObjectiveTo explore effectiveness of reduction and internal fixation via modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column.MethodsBetween January 2016 and September 2018, 19 patients diagnosed as tibial plateau fractures involving posterolateral column were treated with reduction and internal fixation via modified anterolateral supra-fibular-head approach. There were 11 males and 8 females with an average age of 43.2 years (range, 28-65 years). The causes of tibial fracture were traffic accident (12 patients), falling injury (5 patients), and falling from height (2 patients). According to the Schatzker typing, the tibial fractures were rated as type Ⅱ in 9 cases, type Ⅲ in 4 cases, type Ⅴ in 4 cases, and type Ⅵ in 2 cases. The time from injury to operation was 5-13 days (mean, 8.5 days). There were 2 patients with osteoporosis. The operation time, intraoperative blood loss, and postoperative complications were recorded. The knee X-ray film was reviewed regularly to observe the fracture healing. At last follow-up, the fracture reductions were evaluated by Rasmussen radiological score. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score system.ResultsThe average operation time was 95 minutes (range, 65-130 minutes). The average intraoperative blood loss was 220 mL (range, 150-350 mL). All incisions healed by first intention. No complications such as infection or deep venous thrombosis occurred. All patients were followed up 12-20 months (mean, 15.4 months). X-ray films showed that the fractures healed with the healing time of 12-20 weeks (mean, 14.5 weeks). No complications such as loosening or breakage of internal fixation occurred. At last follow-up, according to the Rasmussen radiological score, the fracture reductions were evaluated as excellent in 13 cases, good in 4 cases, fair in 1 case, and poor in 1 case. HSS scores of knee joint function were excellent in 14 cases, good in 3 cases, fair in 1 case, and poor in 1 case. The knee joint range of motion was 90°-135°, with an average of 113.4°.ConclusionApplication of modified anterolateral supra-fibular-head approach in reduction and internal fixation for tibial plateau fractures involving posterolateral column has the advantages of full exposure, less trauma, safety, and reliable reduction and fixation.

          Release date:2020-07-07 07:58 Export PDF Favorites Scan
        • RECONSTRUCTION OF MALUNITED FRACTURE OF TIBIAL PLATEAU

          Objective To explore the treatment of the malunited fracture of the tibial plateau. Methods From June 2000 to June 2005, reconstruction was performed on 29 patients (18 males, 11 females; age, 1943 years, average, 31.6 years) with the malunited fracture of the tibial plateau. The injury duration ranged from 2.5 months to 2 years, averaged 9.7 months. After the injury, the plasterexternal fixation was performed on 8 patients and operation was performed on the other 21 patients. The operation was involved in the use of screws in 11 patients, anatomic plates, Golf plates and allotype plates in 8 patients, external fixation braces in 2 patients. A complicating injury to the anterior cruciate ligament (ACL) was found in 4 patients, an injury to the posterior cruciate ligament(PCL) in 2 patients, an injury to both ACL and PCL in 1 patient, and an injury to the meniscus in 6 patients. Reestablishment was performed on 19 patients, high tibial osteotomy on 7 patients, and osteotomy of the half tibial metaphysis on3 patients. Results Base on the followup for 8 months to 3 years(average, 13.6 months), the comprehensively scoring assessment showed that an excellent result was achieved in 8 patients, good in 15, fair in 4, and poor in 1, with an excellent and good rate of 82.1%, according to the Hohl knee joint function assessment on the pain, active movement, motion range, stability, and selfassessment. ConclusionFor the reconstruction of the malunited fracture of the tibial plateau, the satisfactory therapeutic effectiveness can only be achieved if the proper indications are identified and the suitable operative methods are adopted. The total knee replacement is only applicable to the elderly patient, and for the young patient, the reconstruction should be performed.

          Release date:2016-09-01 09:20 Export PDF Favorites Scan
        • Biomechanical study of nickel-titanium three-dimensional memory alloy mesh and autologous bone in treatment of canine tibial plateau collapse fracture

          ObjectiveTo evaluate the biomechanical effect of a nickel-titanium (Ni-Ti) three-dimensional memory alloy mesh in treating a canine tibial plateau collapse fracture model and to lay a foundation for further experiments in vivo.MethodsSixteen tibial plateau specimens of 8 adult Beagle dogs were harvested. Twelve specimens were taken to prepare canine tibial plateau collapse fracture models (Schatzker type Ⅲ) and randomly divided into groups A, B, and C, with 4 specimens in each group. Four normal tibia specimens were used as blank control group (group D). In groups A and B, the bone defects were repaired with Ni-Ti three-dimensional shape memory alloy mesh combined with autologous bone and simple autologous bone respectively, and fixed with the lateral plate and screw. In group C, the bone defect was directly fixed with the lateral plate and screw. By using a biomechanical tester, a progressive load (0-1 700 N) was loaded vertically above the femoral condyle. The maximum failure load was recorded and the stiffness was calculated according to the load-displacement curve.ResultsThe maximum failure loads in groups A, B, C, and D were (1 624.72±7.02), (1 506.57±3.37), (1 102.00±1.83), and (1 767.64±24.56) N, respectively; and the stiffnesses were (129.72±20.83), (96.54±27.05), (74.96±17.70), and (169.01±35.62) N/mm, respectively. The maximum failure load and stiffness in group A were significantly higher than those in groups B and C, but which were significantly lower than those in group D (P<0.05).ConclusionNi-Ti three-dimensional memory alloy mesh combined with autologous bone can repair the Schatzker type Ⅲ tibial plateau collapse fracture, which has better biomechanical properties than simple autologous bone grafting.

          Release date:2018-05-30 04:28 Export PDF Favorites Scan
        • Application of Allg?wer-Donati suture in internal fixation of Schatzker type Ⅴand Ⅵ tibial plateau closed fractures

          Objective To investigate the effectiveness of Allg?wer-Donati suture in open reduction and internal fixation of Schatzker type Ⅴ and Ⅵ tibial plateau closed fractures. Methods A clinical data of 60 patients with Schatzker type type Ⅴ and Ⅵ tibial plateau closed fractures, who met the selection criteria and admitted between May 2022 and May 2023, was retrospectively analyzed. After open reduction and internal fixation via double incisions, the incisions were closed with conventional mattress suture in 30 cases (control group) and Allg?wer-Donati suture in 30 cases (observation group). There was no significant difference in gender, age, fracture side and type, time from injury to operation, body mass index, and other baseline data between the two groups (P>0.05). The incidence of incision-related complications after operation, visual analogue scale (VAS) score of incision at 3 days and 1 and 2 weeks after operation, and the short-form 36 health survey scale (SF-36) [physical functioning (PF), role physical (RP), bodily pain (BP), and general health (GH)] at 12 weeks after operation were compared between the two groups. Results All operations of the two groups successfully completed. All patients were followed up 6-14 months (mean, 12 months). Incision fluid leakage occurred in 1 case of observation group and 7 cases of control group within 1 week after operation, and the incisions healed after symptomatic treatment. The incisions of other patients healed by first intention. The incidence of early incision complications in observation group was significantly lower than that in control group (P<0.05). No late incision complications was found in the two groups. There was no significant difference in VAS scores at each time point between the two groups (P>0.05). The VAS score significantly decreased with the increase of time in the two groups, showing significant differences between the different time points (P<0.05). There was no significant difference in SF-36 scores (PF, RP, BP, and GH) between the two groups at 12 weeks after operation (P>0.05). Conclusion Compared with conventional mattress suture, Allg?wer-Donati suture is effective in open reduction and internal fixation via double incisions for Schatzker type Ⅴand Ⅵ tibial plateau closed fractures, which can reduce the incidence of early incision complications.

          Release date:2024-06-14 09:52 Export PDF Favorites Scan
        • CLINICAL STUDY ON TREATMENT OF POSTEROLATERAL FRACTURE OF TIBIAL PLATEAU VIA SUPERIOR FIBULAR HEAD APPROACH

          Objective To observe the effectiveness of the superior fibular head approach for the treatment of posterolateral fracture of the tibial plateau. Methods Between June 2010 and February 2012, 20 cases of posterolateral fracture of the tibial plateau were treated through superior fibular head approach, including 1 case of simple posterolateral fracture of the tibial plateau and 19 cases of posterolateral fracture of the tibial plateau with other fractures. There were 12 males and 8 females with an average age of 42.2 years (range, 28-58 years). All patients had closed fractures. Fracture was caused by traffic accident in 14 cases, by falling from height in 4 cases, and by twist injury in 2 cases. Associated injuries included lateral meniscus injury in 5 cases, medial meniscus injury in 2 cases, and anterior cruciate ligament injury in 1 case. The time from injury to admission ranged from 90 minutes to 32 hours (mean, 4.5 hours), and the time from admission to operation was 5-12 days (mean, 7.8 days). All cases underwent fracture reduction and fixation with Pilon plates through the superior fibular head approach, and associated fracture and meniscal injury were treated. Results All incisions healed by first intention, and no numbness or articular instability occurred. All patients were followed up 6-26 months (mean, 19.1 months). The average fracture healing time was 10.2 weeks (range, 8-12 weeks). During following-up, no related complication of fixation loosening or articular surface loss occurred. According to Rasmussen knee score criteria at last follow-up, the score was 18-30 (mean, 27.9); 16 cases were graded as excellent, 3 cases as good, and 1 case as fair, with an excellent and good rate of 95%. Conclusion The superior fibular head approach for the treatment of posterolateral fracture of the tibial plateau is simple, safe, and effective, and can achieve a good surgical outcome.

          Release date:2016-08-31 04:06 Export PDF Favorites Scan
        • CORRECTION OF VARUS KNEE WITH REDUCTION OSTEOTOMY DURING TOTAL KNEE ARTHROPLASTY

          ObjectiveTo evaluate the effectiveness of reduction osteotomy for correction of varus knee during total knee arthroplasty. MethodsA retrospective analysis was made on the clinical data of 16 patients (24 knees) who received reduction osteotomy for correcting varus knee during total knee arthroplasty between May 2010 and July 2012. There were 2 males (3 knees) and 14 females (21 knees), with an average age of 67 years (range, 57-79 years). The disease duration ranged from 3 to 15 years (mean, 9.1 years). The Knee Society Score (KSS) was 38.71±10.04 for clinical score and 50.31±14.31 for functional score. The range of motion (ROM) of the knee was (91.88±13.01)°. The tibiofemoral angle was (9.04±4.53)° of varus deformity. Reduction osteotomy was applied to correct varus knee. ResultsThe operation time was 85-245 minutes (mean, 165.5 minutes); the obvious blood loss was 10-800 mL (mean, 183.1 mL); the hospitalization time was 8-22 days (mean, 13.6 days). All incisions healed by first intention. No neurovascular injury or patellar fracture occurred. The follow-up duration ranged from 37 to 62 months (mean, 48 months). The tibiofemoral angle was corrected to (3.92±1.89)° of valgus at 48 hours after operation. The lower limb alignment recovered to normal. The X-ray films showed no evidence of obvious radiolucent line, osteolysis, or prosthesis subsidence. The results of KSS were significantly improved to 84.21±6.49 for clinical score and 85.31±6.95 for functional score (t=20.665, P=0.000; t=9.585, P=0.000); and ROM of the knee was significantly increased to (105.83±11.29)° (t=8.333, P=0.000) at last follow-up. ConclusionThe effectiveness of reduction osteotomy for varus knee deformity during total knee arthroplasty is satisfactory. Proper alignment, ROM, and function of knee can be achieved.

          Release date: Export PDF Favorites Scan
        • Posterolateral minimal incision, poking reduction, and simple internal fixation in treatment of collapsed fractures of posterolateral tibial plateau

          Objective To explore the effectiveness of limited incision, poking reduction, and simple internal fixation in the treatment of collapsed fractures of the posterolateral tibial plateau. Methods Between October 2010 and January 2016, 16 patients with collapsed fractures of the posterolateral tibial plateau underwent posterolateral incision, poking reduction, and simple internal fixation. There were 10 males and 6 females with the age of 22-63 years (mean, 43.5 years). The injury was caused by falling in 5 cases, traffic accident in 7 cases, and falling from height in 4 cases. All cases had closed fractures. The left knee was involved in 9 cases and the right knee in 7 cases. The injury-to-admission time was 2 hours to 3 days (mean, 10 hours). X-ray films showed that the articular surface collapsing was more than 2 mm. According to Schatzker criteria, 6 cases were rated as type II and 10 cases as type III. Twelve cases had fracture of fibular head. The incision length, operation time, intraoperative blood loss, and incision healing were recorded; fracture healing was observed, and tibial plateau angle and posterior slope angle were measured on X-ray films; loss of articular surface reduction was observed by CT scan; and American Hospital for Special Surgery (HSS) score was used to evaluate the knee joint function. Results The incision length was 7-10 cm (mean, 8.6 cm); operation time was 35-55 minutes (mean, 46 minutes); intraoperative blood loss was 10-35 mL (mean, 28 mL). Primary healing of incision was obtained. Skin pain occurred in 1 case at 2 months because Kirschner wire retracted. Fifteen cases were followed up 8-21 months (mean, 13.5 months). The fracture healing time was from 3 to 6 months (mean, 4.8 months). There was no significant difference in tibial plateau angle and posterior slope angle between at immediate after operation and at last follow-up (t=–1.500, P=0.156; t=–1.781, P=0.097). The anatomic reduction rate of articular surface was 93.8% (15/16) at immediate after operation. At last follow-up, the recollapse height of articular surface was 0.1-1.2 mm (mean, 0.36 mm). According to the HSS score system, the results were excellent in 12 cases, good in 2 cases, and fair in 1 case, and the excellent and good rate was 93.3%. Conclusion The limited incision by posterolateral approach, poking reduction, and simple internal fixation have the advantages of small injury, full exposure, and easy operation in the treatment of simple posterolateral tibial plateau fractures; bone graft support and simple internal fixation can prevent recollapse of the articular surface and achieve satisfactory knee function.

          Release date:2017-07-13 11:11 Export PDF Favorites Scan
        • Efficacy and safety of multiple-dose intravenous tranexamic acid for reducing blood loss in complex tibial plateau fractures: A prospective randomized controlled trial

          ObjectiveTo investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial. MethodsA study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference (P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion. Results ① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups (P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups (P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant (P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant (P>0.05). There was no significant difference in the operation time between groups (P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups (P<0.05); there was no significant difference between the single- and multiple-dose TXA groups (P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant (P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups (P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups (P>0.05), while there was a significant difference in IL-6 between groups (P<0.05). Conclusion Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.

          Release date:2023-09-07 04:22 Export PDF Favorites Scan
        • Clinical study on the subchondral screw compression technique assisted reduction of residual or secondary collapse of lateral tibial plateau

          Objective To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation. Methods Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score. Results All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] (P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.ConclusionThe subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.

          Release date:2023-12-12 05:09 Export PDF Favorites Scan
        2 pages Previous 1 2 Next

        Format

        Content

          1. <div id="8sgz1"><ol id="8sgz1"></ol></div>

            <em id="8sgz1"><label id="8sgz1"></label></em>
          2. <em id="8sgz1"><label id="8sgz1"></label></em>
            <em id="8sgz1"></em>
            <div id="8sgz1"><ol id="8sgz1"><mark id="8sgz1"></mark></ol></div>

            <button id="8sgz1"></button>
            欧美人与性动交α欧美精品